BLINDS CONTROL MODULE (power)

This module provides control of curtains, projector screens, valves, or other electrical
motors with force control. It has 6 inputs for connecting buttons and reed switches.

Example of connection.

hw="in='+TKBBB' out='B'"

Module parameters

Parameter name Value
Output channels qty 2
Input channels qty 6
Buttons
LED Buttons
6
5
Input voltage 100-250 V AC
Current type AC
Max load per channel 1 A (220W at 220V)
Backlight voltage 3V
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 30 mA
Bus type CAN (4-wire)
Mounting Free
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 25 g

 

Module installation and connection procedure

  1. Connect the outputs.
  2. Connect the inputs.
  3. Connect the CAN connector.
  4. Configure the module using LT setup.
  5. Apply power to the load.
  6. Check all equipment for proper operation.

Module shut-off and deinstallation procedure

  1. Disconnect the power from the load
  2. Disconnect the CAN connector.
  3. Disconnect the inputs.
  4. Disconnect the outputs.

HW Settings

Name Type, range SUBID Default Description
runtime integer 0-100 1-2 15 Runtime is the open/close time in seconds, is used for jalousie(2 pole), gate(2 pole), valve(2 pole); Example: rumtime=20
hold integer 0-10000 1-2 500 Hold is the bridging time in miliseconds, is used for gate(1 pole), lock; Example: hold=3500
def string 'ON' 1-2 'OFF' Def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
offset float(+/- 0…39) 11-16 '0' Def is the element status is set after restart; Example: offset='-15'
out char[2] 98 'B-' Each char is responsible for the type of a particular channel

  • ‘L’-Lamp,
  • ‘M’-Lamp Inverse,
  • ‘J’-Heating NO,
  • ‘H’-Heating NC,
  • ‘B’-Blinds (2 pole),
  • ‘C’-Blinds Inverse (2 pole),
  • ‘G’-Gate (2 pole),
  • ‘D’-Gate (2 pole) Inverse,
  • ‘X’-Gate (1 pole /short press),
  • ‘Z’-Gate (1 pole) Inverse,
  • ‘V’-Valve (2 pole),
  • ‘W’-Valve (2 pole) Inverse,
  • ‘R’-Valve (1 pole),
  • ‘S’-Valve (1 pole) Inverse,
  • ‘K’-Lock (short press),
  • ‘N’-Lock (short press) Inverse,
  • ‘-‘-none

Example:

hw="out='LM'"
in char[6] 98 'KKKSSS' Each char is responsible for the type of a particular channel

  • ‘B’-Button,
  • ‘C’-Inverted button,
  • ‘D’-Backlit button,
  • ‘E’-Inverted backlit button,
  • ‘S’-Switch,
  • ‘K’-Contact,
  • ‘H’-Inverted contact,
  • ‘-‘-none

and you can also connect one temperature sensor

in='+T----'

Example:

hw"in='BBBKKK'"

Input HW configuration

hold is the bridging time, is used for gate(1 pole), lock;

channel 1 2 3 4 5 6
Button
nButton
Switch
Contact
nContact
none
+ + + + + +
LedButton
nLedButton
+ + + + +
Temperature Sensor +

Example:

<item addr="508:1" cfgid="52" name="Valve" type="valve" uniq_id="4169"/>
<item addr="508:14" cfgid="52" name="Door" type="door-sensor" uniq_id="4168"/>
<item addr="508:15" cfgid="52" name="Switch" type="switch" uniq_id="4128"/>
<item addr="508:30" cfgid="52" name="Temperature" hw="offset='-10'" type="temperature-sensor" uniq_id="4171"/>
<item addr="508:97" cfgid="52" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3998"/>
<item addr="508:98" cfgid="52" hw="out='V-' in='+T-KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>