eeEmulWrite — recording of one byte into read-only memory .
 

Description:

u8 eeEmulWrite(u8 addr, u32 value);

Records the cell with the address addr, one byte value to the read-only memory and returns the result of recording process.

List of parameters

addr

Cell address in the read-only memory. Value from 1 to 127.

value

Information byte which is required to be stored in the read-only memory .

Return values:

· Returns 0 if the error occurred when storing.

· Returns not 0 if storage was successful.

Example:

<item addr="524:248" name="Test for eeEmulWrite function" type="script">
V-ID/V-ADDR {
        	u8 addr = 4;
        	if(opt0()) {
                    	u32 testWriteVar = 41;
                    	u8 resultOfWrite = eeEmulWrite(addr, testWriteVar);  
                    	u8 strForMess[70]; 
                    	sprintf(strForMess, "%cValue %d", 1, testWriteVar);
                    	if(resultOfWrite != 0) {
                               	strcat(&strForMess, " recorded");
        	        	} else {
                               	strcat(&strForMess, " not recorded");
                    	}
                    	sprintf(strForMess, "%s into a cell %d.", strForMess, addr);
                    	setStatus(@exciterId():32, &strForMess);
        	} else {
                    	u32 testReadVar = 0;
                    	u8 resultOfRead = eeEmulRead(addr, &testReadVar);
                    	u8 strForMess[70]; 
                    	sprintf(strForMess, "%cС cells%d", 4, addr);
                    	if(resultOfRead != 0) {
                               	strcat(&strForMess, " is read");
                    	} else {
                               	strcat(&strForMess, "the value is not read!");
                               	return;
                    	}
sprintf(strForMess, "%s value %d.", strForMess, testReadVar);
                    	setStatus(@exciterId():32, &strForMess);
        	}
}
</item>

The result of performing the example in the interface:

When clicking the element script in the interface the following messages will appear:

“Value 41 is stored to the cell 4”

“Value 41 is read from the cell 4”

Note:

This function supports only the variables of u32 type.