LEAKAGE SENSOR ADAPTER
Allows connecting two leakage sensors, has the function of detecting
the presence of the sensor
Example of connection.
Module parameters
Parameter name | Value |
---|---|
Input channels qty | 2 | Power supply | 11.5 … 27.5 V DC from CAN |
Max current(24V) | 65 mA |
Bus type | CAN (4-wire) |
Computable with | EW-WL, FW-WL |
Output voltage | 12V |
Output current | 20 mA |
Mounting | Free |
Case material | ABS |
Protection | IP40 |
Temperature range | -10 … +50 °C |
Size | 45x42x14 mm |
Weight | 15 g |
Module installation and connection procedure
- Connect the inputs.
- Connect the CAN connector.
- Configure the module using LT setup.
- Check all equipment for proper operation.
Module shut-off and deinstallation procedure
- Disconnect the CAN connector.
- Disconnect the inputs.
HW Settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
leak | char[2] | 98 | ‘LL’ | Each char is responsible for the type of a particular channel
|
Example:
<item addr="312:11" cfgid="67" name="Leak" type="leak-sensor" uniq_id="84"/> <item addr="312:12" cfgid="67" name="Leak" type="leak-sensor" uniq_id="85"/> <item addr="312:98" cfgid="67" hw="leak='LN'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="86"/>