Translations:BW-IO/13/en

From Larnitech wiki page
Jump to navigation Jump to search

HW settings

Name Type, range SUBID Default Description
io char[6] 98 'HHHLLL' Each char is responsible for the type of a particular channel
  • 1-3 channels
    • 'H' – Contact
    • 'K' – Inverted contact
    • 'L' – Backlit button
    • 'M' – Inverted backlit button
  • 4-6 channels
    • 'L'-Lamp
    • 'M'-Lamp Inverse;
    • 'J'-Heating NO, valve-heating, normally open;
    • 'H'-Heating NC, valve-heating, normally closed;
    • 'B'-Blinds, jalousie/curtains(2 pole);
    • 'C'-Blinds Inverse, jalousie/curtains, invert open-close(2 pole);
    • 'G'-Gate (2 pole), 2 pole gate;
    • 'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
    • 'X'-Gate (1 pole /short press), 1 pole gate;
    • 'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
    • 'V'-Valve (2 pole), 2 pole valve,;
    • 'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
    • 'R'-Valve (1 pole), 1 pole valve;
    • 'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
    • 'K'-Lock (short press);
    • 'N'-Lock (short press) Inverse;
    • 'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
    • 'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
    • 'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
    • 'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
    • 'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
    • '-'-none, nothing is connected.

Example:

1hw="io='KKKLLL'"