Translations:Metaforsa MF-10/32/en

From Larnitech wiki page
Jump to navigation Jump to search
Table2
Connector Contact Assignment
1, 3
Mf10l.jpg
L1-2 L3-4 Phase conductor connection for C1-C8 channels load switching
2, 4
Mf10out.jpg
C1-4 C5-8 Load application (light lamps, thermal actuators, etc.)
5
Mf10out2.jpg
С9 L5 С10 Connection of curtain/jalousie/shutter actuators, valve, lamps, gate controllers, etc.: С9, С10 — outputs for load application L5 — connection of group phase supply wire
6
Device status indicators
The module status indicators are described in table 3
7
Mf10power.jpg
+12V GND +12V — module power supply by an external 12 V power supply GND — common
8
Rj45.jpg
RJ45 Connector for LAN connectivity
9-12
Mf10in.jpg
+12V In1 … In16 GND Controlling devices connection (buttons, magnetic reed switches, motion or leakage sensors): +12V — sensor power output +12 V In1 … In16 — logic inputs (0-12 V) GND — common
13
Mf10ow.jpg
OneWire Digital sensors connection (temperature) VCC — sensors power supply output +5V OW1-OW4 — OneWire data buses GND — common
14
Can.jpg
VCC
GND
L
H
External modules connection for CAN-bus VСС — 12V output for external devices power supply GND — common L — CAN-L data bus H — CAN-H data bus