BW-LC02 IS 2-CHANNEL ACTUATOR

Features

  • Compact size (only 16mm thickness)
  • 6 inputs support:
    • Buttons
    • Switches
    • reed switches
    • LED buttons
    • digital temperature sensor
  • Outputs support:
    • Lights
    • NC/NO heating valves
    • NC/NO locks
    • Blinds

    Designed for AC/DC circuits commutation. Applicable for lighting and
    other electrical devices. It has 6 inputs for connecting buttons and reed switches.

    Example of connection.

    hw="in='TKBBBB' out='LL'"

    Module parameters

    Parameter name Value
    Output channels qty 2
    Input channels qty 6
    Buttons
    LED Buttons
    6
    5
    Input voltage 100-250 V
    Current type AC/DC
    Max load per channel 2 A
    Backlight voltage 3V
    Power supply 11.5 … 27.5 V DC from CAN
    Max current(24V) 35 mA
    Permissible section of power supply cable to connect in socket:
    single-conductor cable
    multiple-conductor cable
    tipped multiple-conductor cable
    0.5 … 4mm2
    0.5 … 4mm2
    0.5 … 2.5mm2
    Temperature sensor line max length 10m
    Bus type CAN (4-wire)
    Mounting Free
    Case material ABS
    Protection IP40
    Temperature range -10 … +50 °C
    Size 45x42x14 mm
    Weight 25 g

     

    Module installation and connection procedure

    1. Connect the outputs.
    2. Connect the inputs.
    3. Connect the CAN connector.
    4. Configure the module using LT setup.
    5. Apply power to the load.
    6. Check all equipment for proper operation.

    Module shut-off and deinstallation procedure

    1. Disconnect the power from the load.
    2. Disconnect the CAN connector.
    3. Disconnect the inputs.
    4. Disconnect the outputs.

    HW Settings

    Name Type, range SUBID Default Description
    runtime integer 0-100 1-2 15 runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15
    hold integer 0-10000 1-2 500 hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500
    def string 'ON' 1-2 'OFF' Def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
    offset float(+/- 0…39) 30 '0' sensor values offset;
    For example, offset is -3.8 :

    hw="offset='-3.8'"
    stop Char ‘R’ 1 (for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
    out char[2] 98 'LL' Each char is responsible for the type of a particular channel

    • ‘L’-Lamp,
    • ‘M’-Lamp Inverse,
    • ‘J’-Heating NO,
    • ‘H’-Heating NC,
    • ‘B’-Jalousie (2 pole),
    • ‘C’-Jalousie Inverse (2 pole),
    • ‘P’-Blinds,
    • ‘O’-Blinds Inverse,
    • ‘G’-Gate (2 pole),
    • ‘D’-Gate (2 pole) Inverse,
    • ‘X’-Gate (1 pole /short press),
    • ‘Z’-Gate (1 pole) Inverse,
    • ‘V’-Valve (2 pole),
    • ‘W’-Valve (2 pole) Inverse,
    • ‘R’-Valve (1 pole),
    • ‘S’-Valve (1 pole) Inverse,
    • ‘K’-Lock (short press),
    • ‘N’-Lock (short press) Inverse,
    • ‘F’-Low-current blinds,
    • ‘A’-Low-current blinds Inverse,
    • ‘Q’-Low-current jalousie,
    • ‘E’-Low-current jalousie Inverse,
    • ‘I’-Low-current gate,
    • ‘U’-Low-current gate Inverse,
    • ‘-‘-none

    Example:

    hw="out='LM'"
    in char[6] 98 'BBBBKK' Each char is responsible for the type of a particular channel

    • ‘B’-Button,
    • ‘C’-Inverted button,
    • ‘D’-Backlit button,
    • ‘E’-Inverted backlit button,
    • ‘S’-Switch,
    • ‘K’-Contact,
    • ‘H’-Inverted contact,
    • ‘-‘-none

    and you can also connect one temperature sensor

    in='T-----'

    Example:

    hw="in='BBBKKK'"

    Input HW configuration

    chanel 1 2 3 4 5 6
    Button
    nButton
    Switch
    Contact
    nContact
    none
    + + + + + +
    LedButton
    nLedButton
    + + + + +
    Temperature Sensor +

    Example:

    <item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/>
    <item addr="501:14" cfgid="171" name="Door" type="door-sensor" uniq_id="4168"/>
    <item addr="501:15" cfgid="171" name="Switch" type="switch" uniq_id="4128"/>
    <item addr="501:30" cfgid="171" name="Temperature" hw="offset='-10'" type="temperature-sensor" uniq_id="4171"/>
    <item addr="501:97" cfgid="171" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3998"/>
    <item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>