BUILT-IN FLOOR LEAKAGE SENSOR

Water leakage sensor with an alarm light, mountable in the floor
surface. Used together with DW-WL02 or BW-LSA modules.

Pin assignments

Example of connection

Module parameters

Parameter name Value
Power supply 9-12 V DC
Max current 20 mA
Compatible with MF-10
DW-WL02/HTxx
BW-LSA
Mounting Built into the floor
Case material stainless steel
Protection IP65
Temperature range -10 … +50 °C
Size 18x18x20 mm
Weight 20 g

HW settings

Name Type, range SUBID Default Description
c0 int[4] sensors subId 0;0;255;15 Normal state color in format ‘red;green;blue;blink’
red, green, blue – 0..255;
blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

c0='150;150;255;0'
c1 int[4] sensors subId 0;0;255;15 On-start color in format ‘red;green;blue;blink’
red, green, blue – 0..255;
blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

c1='150;150;255;0'
c2 int[4] sensors subId 255;100;0;15 ‘Leak was previously reported’ color in format ‘red;green;blue;blink’
red, green, blue – 0..255;
blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

c2='150;150;255;0'
c3 int[4] sensors subId 255;0;0;15 On-leak color in format ‘red;green;blue;blink’
red, green, blue – 0..255;
blink:

  • 0 – pulse
  • 1 – blink per 2 seconds
  • 2 – blink per second
  • 15 – constant glow

Example:

c3='150;150;255;0'
sens int sensors subId 128 Sensor sensitivity
Example:

sens='180'

* Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.