<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.larnitech.com/index.php?action=history&amp;feed=atom&amp;title=Translations%3AMetaforsa2_MF-14%2F87%2Fit</id>
	<title>Translations:Metaforsa2 MF-14/87/it - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.larnitech.com/index.php?action=history&amp;feed=atom&amp;title=Translations%3AMetaforsa2_MF-14%2F87%2Fit"/>
	<link rel="alternate" type="text/html" href="https://wiki.larnitech.com/index.php?title=Translations:Metaforsa2_MF-14/87/it&amp;action=history"/>
	<updated>2026-04-24T05:25:42Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.35.11</generator>
	<entry>
		<id>https://wiki.larnitech.com/index.php?title=Translations:Metaforsa2_MF-14/87/it&amp;diff=14395&amp;oldid=prev</id>
		<title>Support: Created page with &quot;==Impostazioni hardware== {| class=&quot;wikitable&quot; |- !Nome!!Tipo, intervallo!!SUBID!!Predefinito!!Descrizione |- |runtime||integer 0-100 || 1-10 || 15 ||il tempo di esecuzione è...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki.larnitech.com/index.php?title=Translations:Metaforsa2_MF-14/87/it&amp;diff=14395&amp;oldid=prev"/>
		<updated>2024-03-04T14:07:06Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;==Impostazioni hardware== {| class=&amp;quot;wikitable&amp;quot; |- !Nome!!Tipo, intervallo!!SUBID!!Predefinito!!Descrizione |- |runtime||integer 0-100 || 1-10 || 15 ||il tempo di esecuzione è...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;==Impostazioni hardware==&lt;br /&gt;
{| class=&amp;quot;wikitable&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
!Nome!!Tipo, intervallo!!SUBID!!Predefinito!!Descrizione&lt;br /&gt;
|-&lt;br /&gt;
|runtime||integer 0-100 || 1-10 || 15 ||il tempo di esecuzione è il tempo di apertura/chiusura in secondi, viene utilizzato per persiane, cancelli, valvole (2 poli);&lt;br /&gt;
&amp;lt;br&amp;gt;Esempio: runtime=15&lt;br /&gt;
|-&lt;br /&gt;
|runtimeopen||integer 0-60000||Blinds subId || ||Runtimeopen è il tempo di apertura in millisecondi, viene utilizzato per le tapparelle; Esempio: runtimeopen=15000&lt;br /&gt;
|-&lt;br /&gt;
|runtimeclose||integer 0-60000||Blinds subId|| ||Runtimeclose è il tempo di chiusura in millisecondi, viene utilizzato per le tapparelle; Esempio: runtimeclose=15000&lt;br /&gt;
|-&lt;br /&gt;
|hold||integer 0-10000||1-10||500||hold è il tempo di bridge in millisecondi, viene utilizzato per cancello e persiana (per impostazione predefinita hold è uguale a runtime per persiana e cancello), lock; Esempio: hold=3500&lt;br /&gt;
|-&lt;br /&gt;
|def||string 'ON'||1-10||'OFF'||def è lo stato dell'elemento impostato dopo il riavvio, viene utilizzato per lampada, riscaldamento, valvola (1 polo); Esempio: def='ON'&lt;br /&gt;
|-&lt;br /&gt;
|stop||Char ‘R’||1-7||–||(per cancello e persiane a 2 poli) Se poi viene dichiarato tramite comando Stop durante il movimento, appare lo stesso impulso che era all'inizio del movimento. Il polo su cui si formano gli impulsi di arresto è definito dal parametro Valore di arresto. Se è &amp;quot;r&amp;quot; o &amp;quot;R&amp;quot;, l'impulso di arresto viene prodotto sul polo opposto all'impulso di avvio. Se viene dichiarato qualsiasi altro valore (ad esempio, &amp;quot;d&amp;quot;), l'impulso di arresto è sullo stesso polo. Se trascorre un tempo di esecuzione dopo l'inizio del movimento, l'impulso di arresto non viene generato. Esempio: stop=’r’&lt;br /&gt;
|-&lt;br /&gt;
|out||char[10]||98||'LLLLHHHHP-'||Ogni carattere è responsabile del tipo di un particolare canale&lt;br /&gt;
*'L'-Lampada;&lt;br /&gt;
*'M'-Lampada inversa;&lt;br /&gt;
*'J'-Riscaldamento NO, valvola di riscaldamento, normalmente aperta;&lt;br /&gt;
*'H'-Riscaldamento NC, riscaldamento con valvola, normalmente chiuso;&lt;br /&gt;
*'B'-Persiane (2 aste), persiane/tende;&lt;br /&gt;
*'C'-Tende inverse (2 poli), persiane/tende, apertura-chiusura invertita;&lt;br /&gt;
*'G'-Gate (2 poli), cancello a 2 poli;&lt;br /&gt;
*'D'-Gate (2 poli) Inverso, cancello a 2 poli, invertito apre-chiude;&lt;br /&gt;
*'X'-Gate (1 polo/pressione breve), cancello a 1 polo;&lt;br /&gt;
*'Z'-Gate (1 polo) Inverso, cancello a 1 polo, invertito apre-chiude;&lt;br /&gt;
*Valvola a 'V' (2 poli), valvola a 2 poli;&lt;br /&gt;
*Valvola 'W' (2 poli) Inversa, valvola a 2 poli, inversione apertura-chiusura;&lt;br /&gt;
*Valvola 'R' (1 polo), valvola 1 polo,;&lt;br /&gt;
*Valvola 'S' (1 polo) Inversa, valvola a 1 polo, inversione apertura-chiusura;&lt;br /&gt;
*'K'-Lock (pressione breve);&lt;br /&gt;
*'N'-Lock (pressione breve) Inverso;&lt;br /&gt;
*'P'-Tende (2 poli);&lt;br /&gt;
*'O'-Blinds Inverse (2 poli), inverte apre-chiude;&lt;br /&gt;
*'F'-FanCoil. Gruppo1 (commutazione lampada). Per il controllo della velocità del fancoil;&lt;br /&gt;
*'E'-FanCoil. Gruppo2 (Commutazione lampada). Per il controllo della velocità del fancoil;&lt;br /&gt;
*'Q'-FanCoil. Gruppo3 (Commutazione lampada). Per il controllo della velocità del fancoil;&lt;br /&gt;
*'U'-FanCoil. Gruppo4 (Commutazione lampada). Per il controllo della velocità del fancoil;&lt;br /&gt;
*'I'-FanCoil. Gruppo5 (Commutazione lampada). Per il controllo della velocità del fancoil;&lt;br /&gt;
*'-'-none, nulla è collegato.&lt;br /&gt;
Esempio: out='LLB-G-V-W-'&lt;br /&gt;
|-&lt;br /&gt;
|dm||char[4]||98||‘LLLL’||Ogni carattere è responsabile del tipo di un particolare canale&lt;br /&gt;
*'g' – utilizzare come lampada dimmerabile alogena&lt;br /&gt;
*'s' – Soft Switch, lampada, quando l'alimentazione on/off viene fornita/disalimentata in modo graduale (500 msec)&lt;br /&gt;
*'k' – Interruttore, lampada, quando l'alimentazione on/off viene fornita/disattivata immediatamente&lt;br /&gt;
*'l' – Funzione LED, lampade LED dimmerabili&lt;br /&gt;
*'v' – Funzione lineare di regolazione&lt;br /&gt;
*'-' – Canale disabilitato&lt;br /&gt;
*'+' – Canale normale&lt;br /&gt;
Esempio: dm=’skl-‘&lt;br /&gt;
|-&lt;br /&gt;
|def||integer 0-250||11-14||100||Il livello di luminosità predefinito in caso di ripristino dell'alimentazione (1..250). Esempio: def=250&lt;br /&gt;
|-&lt;br /&gt;
|min||integer 0-100||11-14||0||Livello minimo di attenuazione, esempio: min=10&lt;br /&gt;
|-&lt;br /&gt;
|max||integer 0-100||11-14||100||Livello massimo di attenuazione, esempio max=95&lt;br /&gt;
|-&lt;br /&gt;
|start||integer 0-100||11-14||0||La funzione Start viene utilizzata per le lampade a cui manca la tensione minima per accendersi. Se il valore impostato è inferiore al valore iniziale, la lampada si accende al valore iniziale e la luce viene attenuata fino al livello impostato. Esempio: start=60&lt;br /&gt;
|-&lt;br /&gt;
|force||integer 0-100||11-14||10||Durata temporale del valore iniziale (misurata in millisecondi). Esempio: force=20&lt;br /&gt;
|-&lt;br /&gt;
|runtime||integer 0-60000||11-14||1000||L'autonomia è la velocità di modifica della luminosità da &amp;quot;min&amp;quot; a &amp;quot;max&amp;quot; (misurata in millisecondi). Esempio:runtime=1000&lt;br /&gt;
|-&lt;br /&gt;
|offset||integer (+/- 0…39)||39-46||'0'||offset dei valori del sensore; Ad esempio, l'offset è -3,8:&lt;br /&gt;
Esempio:hw=&amp;quot;offset='-3.8'&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
|in||char[24]||98||'BBBBBBBBBBBBMMMLLLKKKKKK'||Ogni carattere è responsabile del tipo di un particolare canale&lt;br /&gt;
*Pulsante 'B';&lt;br /&gt;
*'C'-nPulsante;&lt;br /&gt;
*'S'-Cambia;&lt;br /&gt;
*'K'-Contatto;&lt;br /&gt;
*'H'-nContatto;&lt;br /&gt;
*Sensore di perdite &amp;quot;L&amp;quot; Leak, integrato nel pavimento (EW-WL) o sul pavimento (FW-WL)&lt;br /&gt;
*'N'-Sensore di perdite di terze parti;&lt;br /&gt;
*'M'-Motion, sensore di movimento;&lt;br /&gt;
*'V'-nMotion, sensore di movimento;&lt;br /&gt;
*'-'-nessuno&lt;br /&gt;
Esempio: in='MMMMMMMMMMMMLLLLLLLLLLL'&lt;br /&gt;
12 sensori di movimento e 12 sensori di perdite;&lt;br /&gt;
in='BBBBBBBBSSSSSSBBBBSSSSSS'&lt;br /&gt;
12 pulsanti; 12 interruttori.&lt;br /&gt;
|}&lt;/div&gt;</summary>