(8 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | <languages/> | ||
+ | <translate> | ||
+ | <!--T:1--> | ||
+ | {{RevisionChanger | hasA = 1 | hasB = 1 | hasC = 1}} | ||
{{Infobox module | {{Infobox module | ||
| name = DW-HT07.C | | name = DW-HT07.C | ||
Line 13: | Line 17: | ||
}} | }} | ||
− | + | ==7-CHANNEL EXTENSION MODULE== <!--T:2--> | |
− | |||
− | ==7-CHANNEL EXTENSION MODULE== | ||
Has 7 outputs for connecting loads and 12 inputs for connecting | Has 7 outputs for connecting loads and 12 inputs for connecting | ||
various sensors/buttons. | various sensors/buttons. | ||
− | ==Features== | + | ==Features== <!--T:3--> |
+ | <!--T:4--> | ||
*7 universal outputs support: | *7 universal outputs support: | ||
**Lights | **Lights | ||
Line 37: | Line 40: | ||
*4 digital inputs for up to 8 temperature sensors | *4 digital inputs for up to 8 temperature sensors | ||
+ | <!--T:5--> | ||
<div class="caution"> | <div class="caution"> | ||
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | ||
Line 53: | Line 57: | ||
</div> | </div> | ||
− | ==Overview== | + | ==Overview== <!--T:6--> |
[[File:HT07C VIEW.png|500px]] | [[File:HT07C VIEW.png|500px]] | ||
− | ==Example of connection== | + | ==Example of connection== <!--T:7--> |
[[File:HT07C EXA.png|500px]] | [[File:HT07C EXA.png|500px]] | ||
− | ==Module dimensions== | + | ==Module dimensions== <!--T:8--> |
[[File:HT07 DIMM.png|500px]] | [[File:HT07 DIMM.png|500px]] | ||
− | ==Module parameters== | + | ==Module parameters== <!--T:9--> |
+ | <!--T:10--> | ||
{{ Mp | {{ Mp | ||
| outqty = 7 | | outqty = 7 | ||
Line 83: | Line 88: | ||
}} | }} | ||
− | ==Connectivity recommendations== | + | ==Connectivity recommendations== <!--T:11--> |
+ | <!--T:12--> | ||
In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended. | In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended. | ||
The nominal value of the circuit breaker should be calculated based on the maximum total load of connected | The nominal value of the circuit breaker should be calculated based on the maximum total load of connected | ||
Line 92: | Line 98: | ||
for each load. | for each load. | ||
− | ==Connection of actuators== | + | ==Connection of actuators== <!--T:13--> |
+ | <!--T:14--> | ||
<div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire. | <div class="caution"> Caution: Before applying power to the module, you must properly configure the outputs in the application. The contacts configured incorrectly can lead to simultaneous power supply to both channels, resulting in the module failure and/or failure of the equipment connected to it, and even a fire. | ||
If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div> | If free (unused) channels remain in a given group after a curtain/jalousie/shutter actuator with low-voltage control or gate actuator has been connected to it, these channels need to be left unused. (Do not connect other devices to them!) </div> | ||
− | ===Connection of the lights/electric contactor/heating thermal actuator=== | + | ===Connection of the lights/electric contactor/heating thermal actuator=== <!--T:15--> |
+ | <!--T:16--> | ||
[[File:lamps.png|200px]]<br> | [[File:lamps.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 106: | Line 114: | ||
− | ===Connection of high load device=== | + | ===Connection of high load device=== <!--T:17--> |
+ | <!--T:18--> | ||
{| class="wikitable" style="width:800px"; | {| class="wikitable" style="width:800px"; | ||
|- | |- | ||
Line 116: | Line 125: | ||
|} | |} | ||
− | ===Connection of curtain/jalousie/shutter actuator with 220V force control=== | + | ===Connection of curtain/jalousie/shutter actuator with 220V force control=== <!--T:19--> |
+ | <!--T:20--> | ||
[[File:Pjalousie.png|200px]]<br> | [[File:Pjalousie.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 124: | Line 134: | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | ===Connection of curtain/jalousie/shutter actuator with low-voltage control=== | + | ===Connection of curtain/jalousie/shutter actuator with low-voltage control=== <!--T:21--> |
+ | <!--T:22--> | ||
[[File:Ljalousie.png|200px]]<br> | [[File:Ljalousie.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 132: | Line 143: | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | ===Connection of single-pole gate actuator=== | + | ===Connection of single-pole gate actuator=== <!--T:23--> |
+ | <!--T:24--> | ||
[[File:1pgate.png|200px]]<br> | [[File:1pgate.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 140: | Line 152: | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | ===Connection of double-pole gate actuator=== | + | ===Connection of double-pole gate actuator=== <!--T:25--> |
+ | <!--T:26--> | ||
[[File:2pgate.png|200px]]<br> | [[File:2pgate.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 150: | Line 163: | ||
− | ===Connection of single-pole water/gas supply valve=== | + | ===Connection of single-pole water/gas supply valve=== <!--T:27--> |
+ | <!--T:28--> | ||
[[File:1pvalve.png|200px]]<br> | [[File:1pvalve.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 158: | Line 172: | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | ===Connection of double-pole water/gas supply valve=== | + | ===Connection of double-pole water/gas supply valve=== <!--T:29--> |
+ | <!--T:30--> | ||
[[File:2pvalve.png|200px]]<br> | [[File:2pvalve.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 166: | Line 181: | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | ===Connection of fancoil control unit=== | + | ===Connection of fancoil control unit=== <!--T:31--> |
+ | <!--T:32--> | ||
[[File:fancoil.png|200px]]<br> | [[File:fancoil.png|200px]]<br> | ||
Sample HW for this configuration | Sample HW for this configuration | ||
Line 174: | Line 190: | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | ===Example of sensors connection=== | + | ===Example of sensors connection=== <!--T:33--> |
− | [[File: | + | <!--T:34--> |
+ | [[File:SensorsCon4.png|200px]]<br> | ||
2-wire connection recommended | 2-wire connection recommended | ||
− | ==Indication of module operation== | + | ==Indication of module operation== <!--T:35--> |
− | ===Bootloader=== | + | ===Bootloader=== <!--T:36--> |
{{indication}} | {{indication}} | ||
− | ===Firmware mode=== | + | ===Firmware mode=== <!--T:37--> |
{{indicationfw | {{indicationfw | ||
|err1 = 1 | |err1 = 1 | ||
|err2 = 1}} | |err2 = 1}} | ||
+ | |||
+ | ==Module installation and connection procedure== <!--T:38--> | ||
+ | |||
+ | <!--T:39--> | ||
+ | #Connect the outputs. | ||
+ | #Connect the inputs. | ||
+ | #Connect the Can connector. | ||
+ | #Configure the module using LT setup. | ||
+ | #Apply power to the load | ||
+ | #Check all equipment for proper operation. | ||
+ | |||
+ | ==Module shut-off and deinstallation procedure== <!--T:40--> | ||
+ | |||
+ | <!--T:41--> | ||
+ | #Disconnect the power from the load | ||
+ | #Disconnect the CAN connector. | ||
+ | #Disconnect the inputs. | ||
+ | #Disconnect the outputs. | ||
+ | |||
+ | ==HW Settings== <!--T:42--> | ||
+ | |||
+ | <!--T:43--> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | !Name!!Type, range!!SUBID!!Default!!Description | ||
+ | |- | ||
+ | |runtime||integer 0-100||1-7||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 | ||
+ | |- | ||
+ | |runtimeopen||integer 0-60000||Blinds subId||-||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000 | ||
+ | |- | ||
+ | |runtimeclose||integer 0-60000||Blinds subId||-||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000 | ||
+ | |- | ||
+ | |hold||integer 0-10000||1-7||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 | ||
+ | |- | ||
+ | |def||string 'ON'||1-7||'OFF'||def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON' | ||
+ | |- | ||
+ | |stop||Char ‘R’||1-7||–||(for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’ | ||
+ | |- | ||
+ | |out||char[7]||98||'LLLLLLL'||Each char is responsible for the type of a particular channel | ||
+ | *'L'-Lamp; | ||
+ | *'M'-Lamp Inverse; | ||
+ | *'J'-Heating NO, valve-heating, normally open; | ||
+ | *'H'-Heating NC, valve-heating, normally closed; | ||
+ | *'B'-Blinds, jalousie/curtains(2 pole); | ||
+ | *'C'-Blinds Inverse, jalousie/curtains, invert open-close(2 pole); | ||
+ | *'G'-Gate (2 pole), 2 pole gate; | ||
+ | *'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close; | ||
+ | *'X'-Gate (1 pole /short press), 1 pole gate; | ||
+ | *'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close; | ||
+ | *'V'-Valve (2 pole), 2 pole valve; | ||
+ | *'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close; | ||
+ | *'R'-Valve (1 pole), 1 pole valve,; | ||
+ | *'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close; | ||
+ | *'K'-Lock (short press); | ||
+ | *'N'-Lock (short press) Inverse; | ||
+ | *'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control; | ||
+ | *'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control; | ||
+ | *'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control; | ||
+ | *'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control; | ||
+ | *'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control; | ||
+ | *'-'-none, nothing is connected. | ||
+ | Example: out='LLHHHG-' | ||
+ | |- | ||
+ | |offset||float||SubID of OW temperature sensors||'0'||[+/- 0..39] – sensor values offset; | ||
+ | For example, offset is -3.8 : hw="offset='-3.8'" | ||
+ | |- | ||
+ | |in||char[12]||98||'KKKKKKKKKKKK'||Each char is responsible for the type of a particular channel | ||
+ | *'B'-Button; | ||
+ | *'C'-Inverted button; | ||
+ | *'S'-Switch; | ||
+ | *'K'-Contact; | ||
+ | *'H'-Inverted contact; | ||
+ | *'L'-Leak, Built-in floor (EW-WL) or on-the-floor (FW-WL) leakage sensor | ||
+ | *'N'-Third party leakage sensor; | ||
+ | *'M'-Motion, motion sensor; | ||
+ | *'V'-Motion sensor (CW-MSD); | ||
+ | *'-'-none | ||
+ | Example: in='KKKBBBLLLMMM' | ||
+ | |} | ||
+ | |||
+ | <!--T:44--> | ||
+ | <syntaxhighlight lang="xml" line> | ||
+ | <item addr="479:1" auto-period="600" cfgid="42" name="Lamp" type="lamp" uniq_id="145" hw="def='ON'"/> | ||
+ | <item addr="479:2" cfgid="42" name="Radiator" type="valve-heating" uniq_id="146" hw="def='ON'"> | ||
+ | <automation name="Eco" temperature-level="16" uniq_id="147"/> | ||
+ | <automation name="Comfort" temperature-level="22" uniq_id="148"/> | ||
+ | <automation name="Hot" temperature-level="25" uniq_id="149"/> | ||
+ | </item> | ||
+ | <item addr="479:3" cfgid="42" name="Gate" sub-type="120" type="gate" uniq_id="150" hw="runtime=25"/> | ||
+ | <item addr="479:5" cfgid="42" name="Jalousie" sub-type="120" type="jalousie" uniq_id="151" hw="runtime=50"/> | ||
+ | <item addr="479:7" cfgid="42" name="Valve" type="valve" uniq_id="152" hw="def='ON'"/> | ||
+ | <item addr="479:11" cfgid="42" name="Switch" type="switch" uniq_id="153"/> | ||
+ | <item addr="479:12" cfgid="42" name="Switch" type="switch" uniq_id="154"/> | ||
+ | <item addr="479:13" cfgid="42" name="Door" type="door-sensor" uniq_id="133"/> | ||
+ | <item addr="479:14" cfgid="42" name="Door" type="door-sensor" uniq_id="134"/> | ||
+ | <item addr="479:15" cfgid="42" name="Leak" type="leak-sensor" uniq_id="155"/> | ||
+ | <item addr="479:16" cfgid="42" name="Leak" type="leak-sensor" uniq_id="156"/> | ||
+ | <item addr="479:17" cfgid="42" name="Motion" type="motion-sensor" uniq_id="157"/> | ||
+ | <item addr="479:18" cfgid="42" name="Door" type="door-sensor" uniq_id="138"/> | ||
+ | <item addr="479:20" cfgid="42" name="Door" type="door-sensor" uniq_id="140"/> | ||
+ | <item addr="479:21" cfgid="42" name="Motion" type="motion-sensor" uniq_id="158"/> | ||
+ | <item addr="479:97" cfgid="42" name="Temperature" system="yes" type="temperature-sensor" uniq_id="143"/> | ||
+ | <item addr="479:98" cfgid="42" hw="out='LHG-B-R' in='CSKHLNMK-KM-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="144"/> | ||
+ | </syntaxhighlight> | ||
+ | </translate> |
Latest revision as of 10:30, 31 January 2022
DW-HT07.C | |||||||
---|---|---|---|---|---|---|---|
| |||||||
| |||||||
|
7-CHANNEL EXTENSION MODULE
Has 7 outputs for connecting loads and 12 inputs for connecting various sensors/buttons.
Features
- 7 universal outputs support:
- Lights
- NC/NO heating valves
- Blinds
- 1 or 2-pole gates
- 1 or 2-pole valves
- NC/NO locks
- Fan coil units
- 12 Discreet inputs that support:
- Buttons
- Switches
- Reed switches
- Leak sensors
- Motion detectors
- 4 digital inputs for up to 8 temperature sensors
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:
- all connectivity work must be carried out with the power turned OFF;
- use appropriate tools and personal protection against electric shock;
- do not use damaged cables, wires and connectors;
- avoid folding the cables and wires;
- do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
- do not use the power socket with poor contacts to connect;
- do not exceed the load limit parameters specified in the manual;
- the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.
When the power is on, NEVER:
- connect/disconnect the connectors;
- open modules and sensors.
Overview
Example of connection
Module dimensions
Module parameters
Parameter name | Value |
---|---|
Output channels qty | 7 |
Digital line maximum length | 30 m |
Discrete input channels qty | 12 |
Digital input channels qty | 4 |
Input voltage | 0-250V |
Current type | AC/DC |
Max load per channel | 16A |
Power supply | 20.0 … 27.5 V DC from CAN |
Max current(24V) | 140 mA |
Bus type | CAN |
Equipment installation type | DIN rail (EN 60715) |
Case material | ABS |
Protection | IP40 |
Temperature range | -10 … +50 °C |
Size | 4U, 69x115x58 mm |
Weight | 255 g |
Connectivity recommendations
In order to protect the actuator and loads connected to it, installing a circuit breaker is recommended. The nominal value of the circuit breaker should be calculated based on the maximum total load of connected devices and at the same time should not significantly exceed the maximum permissible characteristics of the actuator. Depending on the requirements, you can use one circuit breaker for one actuator (it is recommended) or one circuit breaker per each group of connected loads, or, if necessary, a separate circuit breaker can be installed for each load.
Connection of actuators
Connection of the lights/electric contactor/heating thermal actuator
Sample HW for this configuration
1hw="out='LLL----'"
Connection of high load device
Recomended contactors:
|
Connection of curtain/jalousie/shutter actuator with 220V force control
Sample HW for this configuration
1hw="out='B------'"
Connection of curtain/jalousie/shutter actuator with low-voltage control
Sample HW for this configuration
1hw="out='B------'"
Connection of single-pole gate actuator
Sample HW for this configuration
1hw="out='X------'"
Connection of double-pole gate actuator
Sample HW for this configuration
1hw="out='G------'"
Connection of single-pole water/gas supply valve
Sample HW for this configuration
1hw="out='R------'"
Connection of double-pole water/gas supply valve
Sample HW for this configuration
1hw="out='V------'"
Connection of fancoil control unit
Sample HW for this configuration
1hw="out='FFF----'"
Example of sensors connection
2-wire connection recommended
Indication of module operation
Bootloader
Indicator | Status | Description |
---|---|---|
Device in bootloader | ||
Downloading firmware | ||
Flashing firmware |
Firmware mode
Indicator | Status | Description |
---|---|---|
Identification | ||
Operational mode | ||
Error | ||
Lost connection to server | ||
Overheat |
Module installation and connection procedure
- Connect the outputs.
- Connect the inputs.
- Connect the Can connector.
- Configure the module using LT setup.
- Apply power to the load
- Check all equipment for proper operation.
Module shut-off and deinstallation procedure
- Disconnect the power from the load
- Disconnect the CAN connector.
- Disconnect the inputs.
- Disconnect the outputs.
HW Settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
runtime | integer 0-100 | 1-7 | 15 | runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 |
runtimeopen | integer 0-60000 | Blinds subId | - | Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000 |
runtimeclose | integer 0-60000 | Blinds subId | - | Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000 |
hold | integer 0-10000 | 1-7 | 500 | hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 |
def | string 'ON' | 1-7 | 'OFF' | def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON' |
stop | Char ‘R’ | 1-7 | – | (for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’ |
out | char[7] | 98 | 'LLLLLLL' | Each char is responsible for the type of a particular channel
Example: out='LLHHHG-' |
offset | float | SubID of OW temperature sensors | '0' | [+/- 0..39] – sensor values offset;
For example, offset is -3.8 : hw="offset='-3.8'" |
in | char[12] | 98 | 'KKKKKKKKKKKK' | Each char is responsible for the type of a particular channel
Example: in='KKKBBBLLLMMM' |
1<item addr="479:1" auto-period="600" cfgid="42" name="Lamp" type="lamp" uniq_id="145" hw="def='ON'"/>
2<item addr="479:2" cfgid="42" name="Radiator" type="valve-heating" uniq_id="146" hw="def='ON'">
3 <automation name="Eco" temperature-level="16" uniq_id="147"/>
4 <automation name="Comfort" temperature-level="22" uniq_id="148"/>
5 <automation name="Hot" temperature-level="25" uniq_id="149"/>
6</item>
7<item addr="479:3" cfgid="42" name="Gate" sub-type="120" type="gate" uniq_id="150" hw="runtime=25"/>
8<item addr="479:5" cfgid="42" name="Jalousie" sub-type="120" type="jalousie" uniq_id="151" hw="runtime=50"/>
9<item addr="479:7" cfgid="42" name="Valve" type="valve" uniq_id="152" hw="def='ON'"/>
10<item addr="479:11" cfgid="42" name="Switch" type="switch" uniq_id="153"/>
11<item addr="479:12" cfgid="42" name="Switch" type="switch" uniq_id="154"/>
12<item addr="479:13" cfgid="42" name="Door" type="door-sensor" uniq_id="133"/>
13<item addr="479:14" cfgid="42" name="Door" type="door-sensor" uniq_id="134"/>
14<item addr="479:15" cfgid="42" name="Leak" type="leak-sensor" uniq_id="155"/>
15<item addr="479:16" cfgid="42" name="Leak" type="leak-sensor" uniq_id="156"/>
16<item addr="479:17" cfgid="42" name="Motion" type="motion-sensor" uniq_id="157"/>
17<item addr="479:18" cfgid="42" name="Door" type="door-sensor" uniq_id="138"/>
18<item addr="479:20" cfgid="42" name="Door" type="door-sensor" uniq_id="140"/>
19<item addr="479:21" cfgid="42" name="Motion" type="motion-sensor" uniq_id="158"/>
20<item addr="479:97" cfgid="42" name="Temperature" system="yes" type="temperature-sensor" uniq_id="143"/>
21<item addr="479:98" cfgid="42" hw="out='LHG-B-R' in='CSKHLNMK-KM-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="144"/>