| Line 1: |
Line 1: |
| | + | <languages/> |
| | + | <translate> |
| | + | <!--T:1--> |
| | + | {{RevisionChanger | hasA = 1 | hasC = 1}} |
| | + | {{Infobox module |
| | + | | name = BW-LC02.C |
| | + | | image = BW-LC02C.png |
| | + | | outCount = 2 |
| | + | | peakl = 2A |
| | + | | inCount = 6 |
| | + | | inB = 6 |
| | + | | inLB = 5 |
| | + | | voltage = 11.5...27.5 V DC |
| | + | | dim = 45x42x14 mm |
| | + | }} |
| | | | |
| − | ==2-CHANNEL ACTUATOR== | + | ==2-CHANNEL ACTUATOR== <!--T:2--> |
| | | | |
| | + | <!--T:3--> |
| | Designed for AC/DC circuits commutation. Applicable for lighting and | | Designed for AC/DC circuits commutation. Applicable for lighting and |
| | other electrical devices. It has 6 inputs for connecting buttons and reed switches. | | other electrical devices. It has 6 inputs for connecting buttons and reed switches. |
| | | | |
| − | ==Features== | + | ==Features== <!--T:4--> |
| | *Compact size (only 16mm thickness) | | *Compact size (only 16mm thickness) |
| | *6 inputs support: | | *6 inputs support: |
| Line 18: |
Line 34: |
| | **NC/NO locks | | **NC/NO locks |
| | **Blinds | | **Blinds |
| | + | **Сurtains |
| | + | **Projector screens |
| | + | **Valves |
| | | | |
| | + | WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings |
| | + | |
| | + | <!--T:5--> |
| | <div class="caution"> | | <div class="caution"> |
| | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. |
| Line 35: |
Line 57: |
| | </div> | | </div> |
| | | | |
| − | ==Example of connection== | + | ==Example of connection== <!--T:6--> |
| | | | |
| | + | <!--T:7--> |
| | [[File:LC02C EXA.png|700px]] | | [[File:LC02C EXA.png|700px]] |
| | <br> | | <br> |
| Line 42: |
Line 65: |
| | [[File:LC02C OUT.png|400px]] | | [[File:LC02C OUT.png|400px]] |
| | | | |
| − | ==Module parameters== | + | ==Module parameters== <!--T:8--> |
| | | | |
| | + | <!--T:9--> |
| | {{ Mp | | {{ Mp |
| | | outqty = 2 | | | outqty = 2 |
| Line 49: |
Line 73: |
| | | buttons = 6 | | | buttons = 6 |
| | | ledbuttons = 5 | | | ledbuttons = 5 |
| − | | involtage = 100-250V | + | | involtage = 0-250V |
| | | currtype = AC/DC | | | currtype = AC/DC |
| | | maxperch = 2A | | | maxperch = 2A |
| Line 64: |
Line 88: |
| | | protection = IP40 | | | protection = IP40 |
| | | temprange = -10 … +50 °C | | | temprange = -10 … +50 °C |
| − | | size = 4U, 69x115x58 mm | + | | size = 45x42x14 mm |
| − | | weight = 180 g | + | | weight = 25 g |
| | }} | | }} |
| | | | |
| − | ==Module installation and connection procedure== | + | ==Module installation and connection procedure== <!--T:10--> |
| | | | |
| | + | <!--T:11--> |
| | #Connect the outputs. | | #Connect the outputs. |
| | #Connect the inputs. | | #Connect the inputs. |
| Line 77: |
Line 102: |
| | #Check all equipment for proper operation. | | #Check all equipment for proper operation. |
| | | | |
| − | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:12--> |
| | | | |
| | + | <!--T:13--> |
| | #Disconnect the power from the load. | | #Disconnect the power from the load. |
| | #Disconnect the CAN connector. | | #Disconnect the CAN connector. |
| Line 84: |
Line 110: |
| | #Disconnect the outputs. | | #Disconnect the outputs. |
| | | | |
| − | ==HW settings== | + | ==HW settings== <!--T:14--> |
| | {|class="wikitable" | | {|class="wikitable" |
| | |- | | |- |
| Line 122: |
Line 148: |
| | *'K'-Lock (short press), | | *'K'-Lock (short press), |
| | *'N'-Lock (short press) Inverse, | | *'N'-Lock (short press) Inverse, |
| | + | |
| | + | WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings |
| | + | *'Y'-Low-current lamp, |
| | + | *'T'-Low-current lamp Inverse, |
| | *'F'-Low-current blinds, | | *'F'-Low-current blinds, |
| | *'A'-Low-current blinds Inverse, | | *'A'-Low-current blinds Inverse, |
| Line 153: |
Line 183: |
| | |} | | |} |
| | | | |
| − | ==Input HW configuration== | + | ==Input HW configuration== <!--T:15--> |
| | {| class="wikitable" | | {| class="wikitable" |
| | |- | | |- |
| Line 165: |
Line 195: |
| | |} | | |} |
| | | | |
| | + | <!--T:16--> |
| | <syntaxhighlight lang="xml" line> | | <syntaxhighlight lang="xml" line> |
| | <item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/> | | <item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/> |
| Line 173: |
Line 204: |
| | <item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/> | | <item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/> |
| | </syntaxhighlight> | | </syntaxhighlight> |
| | + | </translate> |