BW-SW06.C | |||||||||
---|---|---|---|---|---|---|---|---|---|
| |||||||||
|
6-CHANNEL INPUT MODULE
This module is used to connect buttons/reed switches.
Features
- 5 inputs support:
- Buttons
- Switches
- Reed switches
- LED buttons
- Digital temperature sensor
Example of connection
Module parameters
Parameter name | Value |
---|---|
Input channels qty | 6 |
Buttons | 6 |
LED Buttons | 5 |
Backlight voltage | 3V |
Power supply | 11.5 … 27.5 V DC from CAN |
Max current(24V) | 30 mA |
Temperature sensor line max length | 10m |
Bus type | CAN (4-wire) |
Equipment installation type | Free |
Case material | ABS |
Protection | IP40 |
Temperature range | -10 … +50 °C |
Size | 45x42x14 mm |
Weight | 25 g |
Module installation and connection procedure
- Connect the inputs.
- Connect the CAN connector.
- Configure the module using LT setup.
- Check all equipment for proper operation.
Module shut-off and deinstallation procedure
- Disconnect the CAN connector.
- Disconnect the inputs.
HW settings
For example, offset is -3.8 :Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
in | char[16] | 98 | 'BBBBBB' | Each char is responsible for the type of a particular channel
And you can also connect one temperature sensor:
|
Input HW configuration
chanel | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
Button nButton Switch Contact nContact none |
+ | + | + | + | + | + |
LedButton nLedButton |
+ | + | + | + | + | |
Temperature Sensor | + |
1<item addr="477:13" cfgid="180" name="Switch" type="switch" uniq_id="78"/>
2<item addr="477:14" cfgid="180" name="Switch" type="switch" uniq_id="79"/>
3<item addr="477:16" cfgid="180" name="Door" type="door-sensor" uniq_id="80"/>
4<item addr="477:30" cfgid="180" hw="offset='15'" name="Temperature" type="temperature-sensor" uniq_id="83"/>
5<item addr="477:98" cfgid="180" hw="in='T+DD-H'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="76"/>