{| class="wikitable" |+ text-align="left"|'''Table2''' |- !Connector!!Contact!!Assignment |- |[[File:Out.png|80px|frameless]] ||1-10|| Load application (light lamps, thermal actuators, etc.) |- |[[File:Dimm.png|80px|frameless]] ||D1-4, L, N|| Load application (dimming lamps) |- | colspan="2"| Device status indicators || The module status indicators are described in '''table 3''' |- |[[File:24vconn.png|80px|frameless]] ||+24V<br>GND|| +24V — module power supply by an external 24 V power supply GND — common |- |[[File:Rj45.jpg|80px|frameless]] ||RJ45|| Connector for LAN connectivity |- |[[File:Inputs.png|80px|frameless]] ||In1-12, In13-24 GND|| Controlling devices connection (buttons, magnetic reed switches, motion or leakage sensors): +12V — sensor power output +12 V<br>In1 … In24 — logic inputs (0-12 V)<br>GND — common |- |[[File:OW.png|80px|frameless]] ||OneWire|| Digital sensors connection (temperature)<br>VCC — sensors power supply output +5V<br>OW1-OW4 — OneWire data buses<br>GND — common |- |[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 24V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus |}
{| class="wikitable"
|+ text-align="left"|'''Table2'''
|-
!Connector!!Contact!!Assignment
|-
|[[File:Out.png|80px|frameless]] ||1-10|| Load application (light lamps, thermal actuators, etc.)
|-
|[[File:Dimm.png|80px|frameless]] ||D1-4, L, N|| Load application (dimming lamps)
|-
| colspan="2"| Device status indicators || The module status indicators are described in '''table 3'''
|-
|[[File:24vconn.png|80px|frameless]] ||+24V<br>GND|| +24V — module power supply by an external 24 V power supply GND — common
|-
|[[File:Rj45.jpg|80px|frameless]] ||RJ45|| Connector for LAN connectivity
|-
|[[File:Inputs.png|80px|frameless]] ||In1-12, In13-24 GND|| Controlling devices connection (buttons, magnetic reed switches, motion or leakage sensors): +12V — sensor power output +12 V<br>In1 … In24 — logic inputs (0-12 V)<br>GND — common
|-
|[[File:OW.png|80px|frameless]] ||OneWire|| Digital sensors connection (temperature)<br>VCC — sensors power supply output +5V<br>OW1-OW4 — OneWire data buses<br>GND — common
|-
|[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| External modules connection for CAN-bus<br>VСС — 24V output for external devices power supply<br>GND — common<br>L — CAN-L data bus<br>H — CAN-H data bus
|}
Translation {| class="wikitable" |+ text-align="left"|'''Table2''' |- !Złącze!!Kontakt!!Przypisanie |- |[[File:Out.png|80px|frameless]] ||1-10|| Zastosowanie obciążenia (lampy świetlne, siłowniki termiczne itp.) |- |[[File:Dimm.png|80px|frameless]] ||D1-4, L, N|| Aplikacja obciążenia (ściemnianie lamp) |- | colspan="2"| Wskaźniki stanu urządzenia || Wskaźniki stanu modułu opisane są w '''tabeli 3''' |- |[[File:24vconn.png|80px|frameless]] ||+24V<br>GND|| +24V — zasilanie modułu z zewnętrznego zasilacza 24 V GND — masa |- |[[File:Rj45.jpg|80px|frameless]] ||RJ45|| Złącze do podłączenia do sieci LAN |- |[[File:Inputs.png|80px|frameless]] ||In1-12, In13-24 GND|| Podłączenie urządzeń sterujących (przyciski, kontaktrony, czujniki ruchu lub przecieków): +12V — wyjście zasilania czujnika +12 V<br>In1 … In24 — wejścia logiczne (0-12 V)<br>GND — wspólny |- |[[File:OW.png|80px|frameless]] ||OneWire|| Podłączenie czujników cyfrowych (temperatury)<br>VCC — wyjście zasilania czujników +5V<br>OW1-OW4 — Magistrale danych OneWire<br>GND — wspólny |- |[[File:Can.jpg|80px|frameless]] ||VCC<br>GND<br>L<br>H|| Podłączenie modułów zewnętrznych do magistrali CAN<br>VСС — wyjście 24V do zasilania urządzeń zewnętrznych<br>GND — masa<br>L — magistrala danych CAN-L<br>H — magistrala danych CAN-H |}
Table2
Złącze
Kontakt
Przypisanie
1-10
Zastosowanie obciążenia (lampy świetlne, siłowniki termiczne itp.)
D1-4, L, N
Aplikacja obciążenia (ściemnianie lamp)
Wskaźniki stanu urządzenia
Wskaźniki stanu modułu opisane są w tabeli 3
+24V GND
+24V — zasilanie modułu z zewnętrznego zasilacza 24 V GND — masa
RJ45
Złącze do podłączenia do sieci LAN
In1-12, In13-24 GND
Podłączenie urządzeń sterujących (przyciski, kontaktrony, czujniki ruchu lub przecieków): +12V — wyjście zasilania czujnika +12 V In1 … In24 — wejścia logiczne (0-12 V) GND — wspólny
OneWire
Podłączenie czujników cyfrowych (temperatury) VCC — wyjście zasilania czujników +5V OW1-OW4 — Magistrale danych OneWire GND — wspólny
VCC GND L H
Podłączenie modułów zewnętrznych do magistrali CAN VСС — wyjście 24V do zasilania urządzeń zewnętrznych GND — masa L — magistrala danych CAN-L H — magistrala danych CAN-H