- '-' - none
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |colspan="3"|Only for Metaforsa 3.plus |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
- SPEED – baud rate [1200..115200];
- B – data length [7,8];
- P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
- S – stop bit length [1, 1.5 or 2].
Example:
1hw="cfg='9600/8N1'"
|- |[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following protocols are supported:
- 'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
- 'dmx', DMX protocol;
- 'CO2' for connecting Larnitech CO2 sensors;
- 'salda' for connecting Salda ventilation.
Example:
1hw="cfg='9600/8N1' modbus"
|- |echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
- 'off'
- 'on'
Example:
1hw="cfg='9600/8N1' echo='off'"
|}