Tags : Mobile web edit Mobile edit
(No difference)
Latest revision as of 08:31, 8 April 2024
Information about message (contribute ) This message has no documentation.
If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Metaforsa 3/3.plus )
*'e' - led-button inverse *'d' - led-button *'c' - button inverse *'b' - button *'s' - switch *'k' - contact inverse *'h' - contact *'l' - leak *'n' - Neptun *'v' - motion inverse *'m' - motion *'r' - thermo-resistor *'t' - DALLAS *'-' - none Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", where *pwm_invert – PWM inverting [1, 0]; *lbn_bright – brightness of led buttons, range (0 - 255); *f – by default PWM frequency is 1000, range (1 - 5000). Example: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Only for Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where *SPEED – baud rate [1200..115200]; *B – data length [7,8]; *P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)]; *S – stop bit length [1, 1.5 or 2]. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following protocols are supported: *'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added; *'dmx', DMX protocol; *'CO2' for connecting Larnitech CO2 sensors; *'salda' for connecting Salda ventilation. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module echo-reply can be turned on or off with the help of this parameter.Echo parameter value: *'off' *'on' Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |}
*'e' - led-button inverse
*'d' - led-button
*'c' - button inverse
*'b' - button
*'s' - switch
*'k' - contact inverse
*'h' - contact
*'l' - leak
*'n' - Neptun
*'v' - motion inverse
*'m' - motion
*'r' - thermo-resistor
*'t' - DALLAS
*'-' - none
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", where
*pwm_invert – PWM inverting [1, 0];
*lbn_bright – brightness of led buttons, range (0 - 255);
*f – by default PWM frequency is 1000, range (1 - 5000).
Example:
<syntaxhighlight lang="xml" line>
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
</syntaxhighlight>
|-
|colspan="3"|'''Only for Metaforsa 3.plus'''
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
*SPEED – baud rate [1200..115200];
*B – data length [7,8];
*P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
*S – stop bit length [1, 1.5 or 2].
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1'"
</syntaxhighlight>
|-
|[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following
protocols are supported:
*'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
*'dmx', DMX protocol;
*'CO2' for connecting Larnitech CO2 sensors;
*'salda' for connecting Salda ventilation.
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' modbus"
</syntaxhighlight>
|-
|echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module
echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
*'off'
*'on'
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' echo='off'"
</syntaxhighlight>
|}
Translation *'e' - led-knap omvendt *'d' - led-knap *'c' - knap omvendt *'b' - knap *'s' - skifte *'k' - kontakt omvendt *'h' - kontakt *'l' - lækage *'n' - Neptun *'v' - bevægelse invers *'m' - bevægelse *'r' - termo-modstand *'t' - DALLAS *'-' - ingen Eksempel: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", hvor *pwm_invert – PWM-invertering [1, 0]; *lbn_bright – lysstyrke af LED-knapper, rækkevidde (0 - 255); *f – som standard er PWM-frekvensen 1000, område (1 - 5000). Eksempel: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Kun til Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', hvor *SPEED – baudrate [1200..115200]; *B – datalængde [7,8]; *P – tilstedeværelse og type af paritetsbit [N(Ingen paritet),E(Lige paritet),O(Ulige paritet)]; *S – stopbitlængde [1, 1,5 eller 2]. Eksempel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Protokolindstilling er beskrevet af protokolparameter. Det følgende protokoller understøttes: *'modbus', Modbus-protokol, ved slutningen af omdirigeringen tilføjes kontrolsummen CRC16(Modbus); *'dmx', DMX-protokol; *'CO2' til tilslutning af Larnitech CO2-sensorer; *'salda' til tilslutning af Salda ventilation. Eksempel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Til indstillinger kan tjek ud og teste ekkoparameteren bruges. modul echo-reply kan slås til eller fra ved hjælp af denne parameter. Echo parameter værdi: *'af' *'på' Eksempel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} 'e' - led-knap omvendt
'd' - led-knap
'c' - knap omvendt
'b' - knap
's' - skifte
'k' - kontakt omvendt
'h' - kontakt
'l' - lækage
'n' - Neptun
'v' - bevægelse invers
'm' - bevægelse
'r' - termo-modstand
't' - DALLAS
'-' - ingen
Eksempel: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", hvor
pwm_invert – PWM-invertering [1, 0];
lbn_bright – lysstyrke af LED-knapper, rækkevidde (0 - 255);
f – som standard er PWM-frekvensen 1000, område (1 - 5000).
Eksempel:
1 hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
|-
|colspan="3"|Kun til Metaforsa 3.plus
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', hvor
SPEED – baudrate [1200..115200];
B – datalængde [7,8];
P – tilstedeværelse og type af paritetsbit [N(Ingen paritet),E(Lige paritet),O(Ulige paritet)];
S – stopbitlængde [1, 1,5 eller 2].
Eksempel:
|-
|[Protocol]||string||98||—||Protokolindstilling er beskrevet af protokolparameter. Det følgende
protokoller understøttes:
'modbus', Modbus-protokol, ved slutningen af omdirigeringen tilføjes kontrolsummen CRC16(Modbus);
'dmx', DMX-protokol;
'CO2' til tilslutning af Larnitech CO2-sensorer;
'salda' til tilslutning af Salda ventilation.
Eksempel:
1 hw="cfg='9600/8N1' modbus"
|-
|echo||on; off||98||'off'||Til indstillinger kan tjek ud og teste ekkoparameteren bruges. modul
echo-reply kan slås til eller fra ved hjælp af denne parameter. Echo parameter værdi:
Eksempel:
1 hw="cfg='9600/8N1' echo='off'"
|}