Tags : Mobile web edit Mobile edit
(No difference)
Latest revision as of 13:04, 8 April 2024
Information about message (contribute ) This message has no documentation.
If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Metaforsa 3/3.plus )
*'e' - led-button inverse *'d' - led-button *'c' - button inverse *'b' - button *'s' - switch *'k' - contact inverse *'h' - contact *'l' - leak *'n' - Neptun *'v' - motion inverse *'m' - motion *'r' - thermo-resistor *'t' - DALLAS *'-' - none Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", where *pwm_invert – PWM inverting [1, 0]; *lbn_bright – brightness of led buttons, range (0 - 255); *f – by default PWM frequency is 1000, range (1 - 5000). Example: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Only for Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where *SPEED – baud rate [1200..115200]; *B – data length [7,8]; *P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)]; *S – stop bit length [1, 1.5 or 2]. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following protocols are supported: *'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added; *'dmx', DMX protocol; *'CO2' for connecting Larnitech CO2 sensors; *'salda' for connecting Salda ventilation. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module echo-reply can be turned on or off with the help of this parameter.Echo parameter value: *'off' *'on' Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |}
*'e' - led-button inverse
*'d' - led-button
*'c' - button inverse
*'b' - button
*'s' - switch
*'k' - contact inverse
*'h' - contact
*'l' - leak
*'n' - Neptun
*'v' - motion inverse
*'m' - motion
*'r' - thermo-resistor
*'t' - DALLAS
*'-' - none
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", where
*pwm_invert – PWM inverting [1, 0];
*lbn_bright – brightness of led buttons, range (0 - 255);
*f – by default PWM frequency is 1000, range (1 - 5000).
Example:
<syntaxhighlight lang="xml" line>
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
</syntaxhighlight>
|-
|colspan="3"|'''Only for Metaforsa 3.plus'''
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
*SPEED – baud rate [1200..115200];
*B – data length [7,8];
*P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
*S – stop bit length [1, 1.5 or 2].
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1'"
</syntaxhighlight>
|-
|[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following
protocols are supported:
*'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
*'dmx', DMX protocol;
*'CO2' for connecting Larnitech CO2 sensors;
*'salda' for connecting Salda ventilation.
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' modbus"
</syntaxhighlight>
|-
|echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module
echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
*'off'
*'on'
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' echo='off'"
</syntaxhighlight>
|}
Translation *'e' - inverzné tlačidlo LED *'d' - tlačidlo LED *'c' - tlačidlo inverzné *'b' - tlačidlo *'s' - prepínač *'k' - inverzný kontakt *'h' - kontakt *'l' - únik *'n' - Neptún *'v' - inverzný pohyb *'m' - pohyb *'r' - tepelný odpor *'t' - DALLAS *'-' - žiadne Príklad: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", kde *pwm_invert – PWM invertovanie [1, 0]; *lbn_bright – jas tlačidiel LED, rozsah (0 - 255); *f – predvolená frekvencia PWM je 1000, rozsah (1 - 5000). Príklad: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Len pre Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', kde *SPEED – prenosová rýchlosť [1200..115200]; *B – dĺžka údajov [7,8]; *P – prítomnosť a typ paritného bitu [N(žiadna parita),E(párna parita),O(nepárna parita)]; *S – dĺžka stop bitu [1, 1,5 alebo 2]. Príklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Nastavenie protokolu popisuje parameter protokolu. Nasledujúci podporované protokoly: *'modbus', protokol Modbus, na konci presmerovania sa pridá kontrolný súčet CRC16(Modbus); *'dmx', DMX protokol; *'CO2' na pripojenie snímačov CO2 Larnitech; *'salda' na pripojenie ventilácie Salda. Príklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Na kontrolu nastavení a testovanie parametra echo je možné použiť. modul echo-reply možno zapnúť alebo vypnúť pomocou tohto parametra. Hodnota parametra Echo: *'vypnuté' *'zap' Príklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} 'e' - inverzné tlačidlo LED
'd' - tlačidlo LED
'c' - tlačidlo inverzné
'b' - tlačidlo
's' - prepínač
'k' - inverzný kontakt
'h' - kontakt
'l' - únik
'n' - Neptún
'v' - inverzný pohyb
'm' - pohyb
'r' - tepelný odpor
't' - DALLAS
'-' - žiadne
Príklad: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", kde
pwm_invert – PWM invertovanie [1, 0];
lbn_bright – jas tlačidiel LED, rozsah (0 - 255);
f – predvolená frekvencia PWM je 1000, rozsah (1 - 5000).
Príklad:
1 hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
|-
|colspan="3"|Len pre Metaforsa 3.plus
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', kde
SPEED – prenosová rýchlosť [1200..115200];
B – dĺžka údajov [7,8];
P – prítomnosť a typ paritného bitu [N(žiadna parita),E(párna parita),O(nepárna parita)];
S – dĺžka stop bitu [1, 1,5 alebo 2].
Príklad:
|-
|[Protocol]||string||98||—||Nastavenie protokolu popisuje parameter protokolu. Nasledujúci
podporované protokoly:
'modbus', protokol Modbus, na konci presmerovania sa pridá kontrolný súčet CRC16(Modbus);
'dmx', DMX protokol;
'CO2' na pripojenie snímačov CO2 Larnitech;
'salda' na pripojenie ventilácie Salda.
Príklad:
1 hw="cfg='9600/8N1' modbus"
|-
|echo||on; off||98||'off'||Na kontrolu nastavení a testovanie parametra echo je možné použiť. modul
echo-reply možno zapnúť alebo vypnúť pomocou tohto parametra. Hodnota parametra Echo:
Príklad:
1 hw="cfg='9600/8N1' echo='off'"
|}