Tags : Mobile web edit Mobile edit
(No difference)
Latest revision as of 13:32, 8 April 2024
Information about message (contribute ) This message has no documentation.
If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Metaforsa 3/3.plus )
*'e' - led-button inverse *'d' - led-button *'c' - button inverse *'b' - button *'s' - switch *'k' - contact inverse *'h' - contact *'l' - leak *'n' - Neptun *'v' - motion inverse *'m' - motion *'r' - thermo-resistor *'t' - DALLAS *'-' - none Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", where *pwm_invert – PWM inverting [1, 0]; *lbn_bright – brightness of led buttons, range (0 - 255); *f – by default PWM frequency is 1000, range (1 - 5000). Example: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Only for Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where *SPEED – baud rate [1200..115200]; *B – data length [7,8]; *P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)]; *S – stop bit length [1, 1.5 or 2]. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following protocols are supported: *'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added; *'dmx', DMX protocol; *'CO2' for connecting Larnitech CO2 sensors; *'salda' for connecting Salda ventilation. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module echo-reply can be turned on or off with the help of this parameter.Echo parameter value: *'off' *'on' Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |}
*'e' - led-button inverse
*'d' - led-button
*'c' - button inverse
*'b' - button
*'s' - switch
*'k' - contact inverse
*'h' - contact
*'l' - leak
*'n' - Neptun
*'v' - motion inverse
*'m' - motion
*'r' - thermo-resistor
*'t' - DALLAS
*'-' - none
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", where
*pwm_invert – PWM inverting [1, 0];
*lbn_bright – brightness of led buttons, range (0 - 255);
*f – by default PWM frequency is 1000, range (1 - 5000).
Example:
<syntaxhighlight lang="xml" line>
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
</syntaxhighlight>
|-
|colspan="3"|'''Only for Metaforsa 3.plus'''
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
*SPEED – baud rate [1200..115200];
*B – data length [7,8];
*P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
*S – stop bit length [1, 1.5 or 2].
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1'"
</syntaxhighlight>
|-
|[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following
protocols are supported:
*'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
*'dmx', DMX protocol;
*'CO2' for connecting Larnitech CO2 sensors;
*'salda' for connecting Salda ventilation.
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' modbus"
</syntaxhighlight>
|-
|echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module
echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
*'off'
*'on'
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' echo='off'"
</syntaxhighlight>
|}
Translation *'e' - inverzna led tipka *'d' - LED-gumb *'c' - inverzni gumb *'b' - gumb *'s' - stikalo *'k' - stik inverzno *'h' - stik *'l' - puščanje *'n' - Neptun *'v' - obratno gibanje *'m' - gibanje *'r' - termo-upor *'t' - DALLAS *'-' - nič primer: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", kje *pwm_invert – obračanje PWM [1, 0]; *lbn_bright – svetlost LED gumbov, obseg (0 - 255); *f – privzeta frekvenca PWM je 1000, razpon (1 - 5000). primer: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Samo za Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', kje *SPEED – hitrost prenosa [1200..115200]; *B – dolžina podatkov [7,8]; *P – prisotnost in vrsta paritetnega bita [N(Brez parnosti),E(Soda parnost),O(Liha parnost)]; *S – dolžina stop bita [1, 1,5 ali 2]. primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Nastavitev protokola je opisana s parametrom protokola. Naslednji podprti so protokoli: *'modbus', protokol Modbus, na koncu preusmeritve se doda kontrolna vsota CRC16(Modbus); *'dmx', protokol DMX; *'CO2' za priključitev senzorjev Larnitech CO2; *'salda' za priklop prezračevanja Salda. primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Za preverjanje nastavitev in testiranje odmevnega parametra je mogoče uporabiti. Modul echo-reply lahko vklopite ali izklopite s pomočjo tega parametra. Vrednost parametra Echo: *'izklopljeno' *'on' primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} 'e' - inverzna led tipka
'd' - LED-gumb
'c' - inverzni gumb
'b' - gumb
's' - stikalo
'k' - stik inverzno
'h' - stik
'l' - puščanje
'n' - Neptun
'v' - obratno gibanje
'm' - gibanje
'r' - termo-upor
't' - DALLAS
'-' - nič
primer: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", kje
pwm_invert – obračanje PWM [1, 0];
lbn_bright – svetlost LED gumbov, obseg (0 - 255);
f – privzeta frekvenca PWM je 1000, razpon (1 - 5000).
primer:
1 hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
|-
|colspan="3"|Samo za Metaforsa 3.plus
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', kje
SPEED – hitrost prenosa [1200..115200];
B – dolžina podatkov [7,8];
P – prisotnost in vrsta paritetnega bita [N(Brez parnosti),E(Soda parnost),O(Liha parnost)];
S – dolžina stop bita [1, 1,5 ali 2].
primer:
|-
|[Protocol]||string||98||—||Nastavitev protokola je opisana s parametrom protokola. Naslednji
podprti so protokoli:
'modbus', protokol Modbus, na koncu preusmeritve se doda kontrolna vsota CRC16(Modbus);
'dmx', protokol DMX;
'CO2' za priključitev senzorjev Larnitech CO2;
'salda' za priklop prezračevanja Salda.
primer:
1 hw="cfg='9600/8N1' modbus"
|-
|echo||on; off||98||'off'||Za preverjanje nastavitev in testiranje odmevnega parametra je mogoče uporabiti. Modul
echo-reply lahko vklopite ali izklopite s pomočjo tega parametra. Vrednost parametra Echo:
primer:
1 hw="cfg='9600/8N1' echo='off'"
|}