Line 24: |
Line 24: |
| While working with the system, you must strictly comply with all the requirements set out in this manual. Failure to comply may result in damage to the device, its failure, electric shock, fire and other fallout. | | While working with the system, you must strictly comply with all the requirements set out in this manual. Failure to comply may result in damage to the device, its failure, electric shock, fire and other fallout. |
| The manufacturer reserves the right to make changes to this manual without prior notice. This manual is an integral part of the system and shall remain with the end-use customer. | | The manufacturer reserves the right to make changes to this manual without prior notice. This manual is an integral part of the system and shall remain with the end-use customer. |
| + | |
| + | <!--T:3.1--> |
| + | <youtube>IC_-C7zVTPc</youtube> |
| | | |
| ==Features== <!--T:4--> | | ==Features== <!--T:4--> |
Line 233: |
Line 236: |
| <nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input | | <nowiki>*</nowiki> – Output channels should only be connected using amplifier which uses 5V PWM signal from IO output as input |
| | | |
| + | <!--T:89--> |
| <nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors | | <nowiki>**</nowiki> – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors |
| | | |
| + | <!--T:90--> |
| <nowiki>***</nowiki> – Only for Metaforsa 3.plus | | <nowiki>***</nowiki> – Only for Metaforsa 3.plus |
| | | |
Line 283: |
Line 288: |
| *connector (7) — expansion module connection. | | *connector (7) — expansion module connection. |
| | | |
| + | <!--T:91--> |
| The physical configuration and contact point assignment of each connector are shown in '''table 2'''. | | The physical configuration and contact point assignment of each connector are shown in '''table 2'''. |
| | | |
Line 309: |
Line 315: |
| {{indicationmfold}} | | {{indicationmfold}} |
| | | |
− | ===System installation and assembly=== <!--T:31--> | + | ===System installation and assembly=== <!--T:31--> |
| Before connecting the system, you must: | | Before connecting the system, you must: |
| | | |
Line 428: |
Line 434: |
| ====Connection of motion sensors/leakage sensors==== <!--T:54--> | | ====Connection of motion sensors/leakage sensors==== <!--T:54--> |
| | | |
− | The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +12V and GND of the relevant group. The example of connection is shown in '''Fig.11'''. | + | <!--T:92--> |
| + | The motion sensors/leakage sensors should be connected to any free input in1-in28; in these conditions their power is connected to the contact points of +5V and GND of the relevant group. The example of connection is shown in '''Fig.11'''. |
| | | |
| <!--T:55--> | | <!--T:55--> |
Line 438: |
Line 445: |
| ====Connection of buttons/switches/magnetic reed switches==== <!--T:56--> | | ====Connection of buttons/switches/magnetic reed switches==== <!--T:56--> |
| | | |
| + | <!--T:93--> |
| Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''. | | Buttons and reed switches are connected to any free input in1-in28, while their second contact point is connected to GND point of the relevant METAFORSA module group. The example of connection is shown in '''Fig. 12-13'''. |
| | | |
Line 640: |
Line 648: |
| *'z' - WS2812B -string | | *'z' - WS2812B -string |
| | | |
| + | <!--T:94--> |
| *'e' - led-button inverse | | *'e' - led-button inverse |
| *'d' - led-button | | *'d' - led-button |
Line 653: |
Line 662: |
| *'r' - thermo-resistor | | *'r' - thermo-resistor |
| *'t' - DALLAS | | *'t' - DALLAS |
− |
| |
| *'-' - none | | *'-' - none |
| Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' | | Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |
| + | |- |
| + | |hw||string||98||-||hw="...", where |
| + | *pwm_invert – PWM inverting [1, 0]; |
| + | *lbn_bright – brightness of led buttons, range (0 - 255); |
| + | *f – by default PWM frequency is 1000, range (1 - 5000). |
| + | Example: |
| + | <syntaxhighlight lang="xml" line> |
| + | hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" |
| + | </syntaxhighlight> |
| |- | | |- |
| |colspan="3"|'''Only for Metaforsa 3.plus''' | | |colspan="3"|'''Only for Metaforsa 3.plus''' |