Changes

Jump to navigation Jump to search
no edit summary
Line 3: Line 3:  
{{Infobox module
 
{{Infobox module
 
| name      = LED-AMP
 
| name      = LED-AMP
| image      = LED-AMP.png
+
| image      = LED-AMP_main.png
 
| outCount  = 4
 
| outCount  = 4
| peakl      = ?
+
| peakl      = 3A
| voltage    = ? V DC
+
| voltage    = 12..24 V DC
| dim        = ? mm
+
| dim        = 65x18x15 mm
 
}}
 
}}
   −
==4-CHANNEL LED Driver== <!--T:2-->
+
==4-CHANNEL LED Amplifier== <!--T:2-->
    
<!--T:3-->
 
<!--T:3-->
This module allows interpretation of controlling signals from IO connections for 12/24V LED/RGB strips.
+
LED-AMP is a simple amplifier that works on the principle of input=output. It is designed for use with LED strips or other LED light devices.
    
<!--T:4-->
 
<!--T:4-->
Line 35: Line 35:     
<!--T:6-->
 
<!--T:6-->
[[File:LED-AMP_connection_scheme.png|800px]]
+
[[File:LED-AMP scheme.jpeg | 600px]]
    
==Module parameters== <!--T:7-->
 
==Module parameters== <!--T:7-->
   −
<!--T:10-->
+
<!--T:8-->
 
{{ Mp
 
{{ Mp
 
| outqty          = 4
 
| outqty          = 4
Line 45: Line 45:  
| currtype        = DC
 
| currtype        = DC
 
| adjtype        = PWM
 
| adjtype        = PWM
| maxperch        = ?
+
| maxperch        = 3A
 
| power          = 11.5 … 27.5 V DC
 
| power          = 11.5 … 27.5 V DC
 
| instalation    = Free
 
| instalation    = Free
Line 51: Line 51:  
| protection      = IP40
 
| protection      = IP40
 
| temprange      = -10 … +50 °C
 
| temprange      = -10 … +50 °C
| size            = ? mm
+
| size            = 65x18x15 mm
| weight          = ? g
+
| weight          = 25 g
 
}}
 
}}
   −
==Module installation and connection procedure== <!--T:8-->
+
==Module installation and connection procedure== <!--T:9-->
   −
<!--T:9-->
+
<!--T:10-->
#Connect the outputs.
+
#Connect the inputs and outputs.
#Configure the module using LT setup.
+
#Configure the module using LT Setup.
 
#Apply power to the load.
 
#Apply power to the load.
 
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
   −
==Module shut-off and deinstallation procedure== <!--T:10-->
+
==Module shut-off and deinstallation procedure== <!--T:11-->
   −
<!--T:11-->
+
<!--T:12-->
 
#Disconnect the power from the load.
 
#Disconnect the power from the load.
#Disconnect the outputs.
+
#Disconnect the inputs and outputs.
editor, translator
36

edits

Navigation menu