Table2
Connector |
Contact |
Assignment
|
|
1-10 |
Load application (light lamps, thermal actuators, etc.)
|
|
D1-4, L, N |
Load application (dimming lamps)
|
Device status indicators |
The module status indicators are described in table 3
|
|
+24V GND |
+24V — module power supply by an external 24 V power supply GND — common
|
|
RJ45 |
Connector for LAN connectivity
|
|
In1-12, In13-24 GND |
Controlling devices connection (buttons, magnetic reed switches, motion or leakage sensors): +12V — sensor power output +12 V In1 … In24 — logic inputs (0-12 V) GND — common
|
|
OneWire |
Digital sensors connection (temperature) VCC — sensors power supply output +5V OW1-OW4 — OneWire data buses GND — common
|
|
VCC GND L H |