Difference between revisions of "Translations:DW-RGB03/23/en"
From Larnitech wiki page
Jump to navigation
Jump to search
Latest revision as of 12:37, 6 January 2022
HW settings
Name |
Type, range |
SUBID |
Default |
Description
|
dm |
char[9] |
98 |
'RGBRGBRGB' |
Each char is responsible for the type of a particular channel, RGB takes 3 channels
- 'RGB' – Use like RGB lamp
- 'L' – LED Function, dimmable LED lamps
- 'G' – Use like halogen dimer-lamp
- 'Y' – Linear Function of dimming
- 'F' – Fancoil
- 'S' – Lamp
- 'M' – Inverse lamp
- 'V' – Valve
- 'W' – Inverse valve
- 'K' – Lock
- 'N' – Inverse lock
- 'H' – Valve heating
- 'J' – Inverse valve heating
- '-' – Channel disabled
Example: dm='LLLRGBLLL'
|
f |
integer 0-1000 |
98 |
500 |
Frequency of rgb LED
Example:hw="f=800"
|
def |
integer 0-250 |
1-5 |
100 |
The default brightness level in case of a power reset (1..250). Example: def=250
|
min |
integer 0-100 |
1-5 |
0 |
Minimum dimming level, example: min=10
|
max |
integer 0-100 |
1-5 |
100 |
Maximum dimming level, example max=95
|
force |
integer 0-100 |
1-5 |
10 |
Time duration of the starting value (measured in milliseconds). Example: force=20
|
runtime |
integer 0-60000 |
1-9 |
5 |
Runtime is the speed of changing the brightness(measured in miliseconds for dimmer and in seconds for RGB). Example: runtime=5000
|