| | | name = DW-WL02.C | | | name = DW-WL02.C |
| | | image = DW-WL02C.png | | | image = DW-WL02C.png |
| − | | outCount = 3 | + | | outCount = 4 |
| | | dimmOut = | | | dimmOut = |
| | | peakl = 5A | | | peakl = 5A |
| | | peakdl = | | | peakdl = |
| | | dt = | | | dt = |
| − | | inDisc = 4 | + | | inSens = 4 |
| − | | inDigit = 2 | + | | inDry = 2 |
| | | voltage = 11.5...27.5 V DC | | | voltage = 11.5...27.5 V DC |
| | | dim = 4U, 69x110x58 mm | | | dim = 4U, 69x110x58 mm |
| | }} | | }} |
| | | | |
| − | ==WATER LEAKAGE PROTECTION MODULE== | + | ==WATER LEAKAGE PROTECTION MODULE== <!--T:2--> |
| | | | |
| | + | <!--T:3--> |
| | The module supports the connection of 2 valves of water supply | | The module supports the connection of 2 valves of water supply |
| | shutoff and 4 leakage sensors (up to 16 FW-WL.B/EW-WL.B ). | | shutoff and 4 leakage sensors (up to 16 FW-WL.B/EW-WL.B ). |
| | | | |
| − | ==Features== | + | ==Features== <!--T:4--> |
| | *Supports 1p/2p valves | | *Supports 1p/2p valves |
| | *Valve feedback reed switch | | *Valve feedback reed switch |
| − | *4 leakage zones | + | *Support up to 16 leakage sensors |
| − | *Ability to connect up to 16 FW-WL.B/EW-WL.B sensors
| |
| | *Sensor detection and diagnostics | | *Sensor detection and diagnostics |
| | + | *Sensor sensitivity adjustment |
| | | | |
| | + | <!--T:5--> |
| | <div class="caution"> | | <div class="caution"> |
| | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. | | CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. |
| Line 42: |
Line 47: |
| | </div> | | </div> |
| | | | |
| − | ==Overview== | + | ==Overview== <!--T:6--> |
| | | | |
| | + | <!--T:7--> |
| | [[File:WL02C VIEW.png|500px]] | | [[File:WL02C VIEW.png|500px]] |
| | <br> | | <br> |
| Line 49: |
Line 55: |
| | [[File:WL02C VIEW2.png|300px]] | | [[File:WL02C VIEW2.png|300px]] |
| | | | |
| − | ==Example of connection== | + | ==Example of connection== <!--T:8--> |
| | | | |
| | + | <!--T:9--> |
| | [[File:WL02C EXA.png|500px]] | | [[File:WL02C EXA.png|500px]] |
| | | | |
| − | ==Module dimensions== | + | ==Module dimensions== <!--T:10--> |
| | | | |
| | + | <!--T:11--> |
| | [[File:WL02C DIM.png|500px]] | | [[File:WL02C DIM.png|500px]] |
| | | | |
| − | ==Internal layout== | + | ==Internal layout== <!--T:12--> |
| | | | |
| | + | <!--T:13--> |
| | [[File:WL02C IL.png|500px]] | | [[File:WL02C IL.png|500px]] |
| | | | |
| | | | |
| − | ==Module parameters== | + | ==Module parameters== <!--T:14--> |
| | | | |
| | + | <!--T:15--> |
| | {{ Mp | | {{ Mp |
| | | outqty = 4 | | | outqty = 4 |
| Line 76: |
Line 86: |
| | | sensmaxvcccur = 70 mA | | | sensmaxvcccur = 70 mA |
| | | rinmaxcur = 3 mA | | | rinmaxcur = 3 mA |
| | + | | smaxlen = 30m |
| | | bustype = CAN (4-wire) | | | bustype = CAN (4-wire) |
| | | instalation = DIN-rail (EN 60715) | | | instalation = DIN-rail (EN 60715) |
| Line 85: |
Line 96: |
| | }} | | }} |
| | | | |
| − | ==Indication of module operation== | + | ==Indication of module operation== <!--T:16--> |
| | ===Bootloader=== | | ===Bootloader=== |
| | {{indication| textBBB= Waiting for bootloader command}} | | {{indication| textBBB= Waiting for bootloader command}} |
| Line 95: |
Line 106: |
| | }} | | }} |
| | | | |
| − | ==Module installation and connection procedure== | + | ==Module installation and connection procedure== <!--T:17--> |
| | #Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. | | #Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base. |
| | #Connect the CAN connector. | | #Connect the CAN connector. |
| Line 103: |
Line 114: |
| | #Check all equipment for proper operation. | | #Check all equipment for proper operation. |
| | | | |
| − | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:18--> |
| | #Disconnect the power from the load. | | #Disconnect the power from the load. |
| | #Disconnect the channels. | | #Disconnect the channels. |
| Line 109: |
Line 120: |
| | #Remove the module from the DIN rail, releasing the latch at the bottom of the module base. | | #Remove the module from the DIN rail, releasing the latch at the bottom of the module base. |
| | | | |
| − | ==HW settings== | + | ==HW settings== <!--T:19--> |
| | {|class="wikitable" | | {|class="wikitable" |
| | |- | | |- |
| Line 115: |
Line 126: |
| | |- | | |- |
| | |runtime||integer 0-100||1-4||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 | | |runtime||integer 0-100||1-4||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15 |
| | + | |- |
| | + | |runtimeopen||integer 0-60000||Blinds subId||-||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000 |
| | + | |- |
| | + | |runtimeclose||integer 0-60000||Blinds subId||-||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000 |
| | |- | | |- |
| | |hold||integer 0-10000||1-4||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 | | |hold||integer 0-10000||1-4||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500 |
| Line 168: |
Line 183: |
| | <item addr="500:98" cfgid="53" hw="leak='NNLL' in='HHKK' out='V-B-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="4116"/> | | <item addr="500:98" cfgid="53" hw="leak='NNLL' in='HHKK' out='V-B-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="4116"/> |