Difference between revisions of "DW-010/en"
Jump to navigation
Jump to search
(Updating to match new version of source page) |
(No difference)
|
Latest revision as of 13:52, 7 January 2022
DW-010.C | |||||||
---|---|---|---|---|---|---|---|
| |||||||
| |||||||
|
MODULE FOR DEVICES WITH 0-10V INPUT OR OUTPUT
This module allows connecting devices with 0-10V inputs and outputs to the Smart Home system
Features
- 4x0-10V outputs
- 2x0-10V inputs
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:
- all connectivity work must be carried out with the power turned OFF;
- use appropriate tools and personal protection against electric shock;
- do not use damaged cables, wires and connectors;
- avoid folding the cables and wires;
- do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
- do not use the power socket with poor contacts to connect;
- do not exceed the load limit parameters specified in the manual;
- the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.
When the power is on, NEVER:
- connect/disconnect the connectors;
- open modules and sensors.
Overview
Module dimensions
Connection of 6 0-10V devices
Module parameters
Parameter name | Value |
---|---|
Input channels qty | 2 |
Output channels qty | 4 |
Max load per channel | 15mA |
Power supply | 11.5 … 27.5 V DC from CAN |
Max current(24V) | 50 mA |
Push-button/reed switches line recommended length | 30m |
Bus type | CAN (4-wire) |
Equipment installation type | DIN rail (EN 60715) |
Case material | ABS |
Protection | IP40 |
Temperature range | -10 … +50 °C |
Size | 2U, 36x97x58 mm |
Weight | 130g |
Indication of module operation
Bootloader
Indicator | Status | Description |
---|---|---|
Device in bootloader | ||
Downloading firmware | ||
Flashing firmware |
Firmware
Indicator | Status | Description |
---|---|---|
Identification | ||
Operational mode | ||
Error | ||
Lost connection to server | ||
Overheat |
Module installation and connection procedure
- Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base.
- Connect the input/output connectors.
- Connect the CAN connector.
- Configure the module using LT setup.
- Check all equipment for proper operation.
Module shut-off and deinstallation procedure
- Disconnect the CAN connector.
- Disconnect the input/output connectors.
- Remove the module from the DIN rail, releasing the latch at the bottom of the module base.
HW settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
def | integer 0-250 | 1-4 | 100 | The default brightness level in case of a power reset (1..250). Example: def=250 |
min | integer 0-100 | 1-4 | 0 | Minimum dimming level, example: min=10 |
max | integer 0-100 | 1-4 | 100 | Maximum dimming level, example max=95 |
start | integer 0-100 | 1-4 | 0 | The Start function is used for lamps that lack the minimal voltage to get turned on. If the set value is lower than the start value, the lamp is turned on at the start value and them the light is dimmed down to the set level. Example: start=60 |
force | integer 0-100 | 1-4 | 10 | Time duration of the starting value (measured in milliseconds). Example: force=20 |
runtime | integer 0-60000 | 1-4 | 1000 | Runtime is the speed of changing the brightness from ‘min’ to ‘max’ (measured in milliseconds). Example: runtime=1000 |
dm | char[4] | 98 | 'vvvv' | Each char is responsible for the type of a particular channel
Example: dm='skl-' |
1<item addr="416:1" auto-period="600" cfgid="144" name="Dimmer 1" type="dimmer-lamp"/>
2<item addr="416:2" auto-period="600" cfgid="144" name="Dimmer 2" type="dimmer-lamp"/>
3<item addr="416:3" auto-period="600" cfgid="144" name="Dimmer 3" type="dimmer-lamp"/>
4<item addr="416:4" auto-period="600" cfgid="144" name="Dimmer 4" type="dimmer-lamp"/>
5<item addr="416:31" cfgid="144" name="Voltage" system="yes" type="voltage-sensor"/>
6<item addr="416:32" cfgid="144" name="Voltage" system="yes" type="voltage-sensor"/>
7<item addr="416:97" cfgid="144" name="Temperature" system="yes" type="temperature-sensor"/>
8<item addr="416:98" cfgid="144" logic-ver="19" name="Temperature" system="yes" type="temperature-sensor"/>