Difference between revisions of "DE-MG.plus"

From Larnitech wiki page
Jump to navigation Jump to search
Line 47: Line 47:
 
|Number of CAN ports||2
 
|Number of CAN ports||2
 
|-
 
|-
|Power supply||11.5 … 27.5 V DC
+
|Power supply||11.5 … 27.5 V DC<br>24V, 2.5A Recommended
|-
 
|24V, 2.5A Recommended
 
 
|-
 
|-
 
|Max own current (24V)||140mA
 
|Max own current (24V)||140mA

Revision as of 06:47, 26 July 2021

DE-MG.plus
DE-MGP.png
General
Type of connectionCAN, Ethernet
Input/output interfacesEthernet, 2xCAN, EIB, Bluetooth
Max CAN devices100(50 per CAN)
CAN port qty2
Max CAN bus length800 m (twisted pair 5 cat)
Max current per CAN bus700mA
Other
Supply voltage11.5...27.5 V DC
Dimentions6U, 104x90x58 mm


MAIN GATEWAY

It is used for accumulation and storage of system data. The device determines the logical scheme of the system and allows authorized access to the system via the Internet. It also converts Ethernet into CAN bus and vice versa. DE-MG has a built-in IR receiver.The DE-MG can be controlled via cloud with a securely encrypted signal. The system history from all other devices and sensors is stored on the DE-MG for one year. Its plug and play feature means that it automatically detects and configures new Larnitech devices that are added to the system. A large and constantly updated database of ready-made scripts ensures that your home does everything your heart may desire. Get things going by telling your home what to do with the help of Siri, Alexa or Google Home. Get push notifications on your phone whenever the system has things to tell you and enjoy the ultimate control at your fingertips

Module view

DE-MGP VIEW.png

  1. Indicators
  2. IR Reсiever
  3. Recovery button
  4. Power supply
  5. CAN1
  6. CAN2
  7. Ethernet
  8. EiB

Сonnection example

DE-MGP EXA.png

Module parameters

Parameter name Value
Type of connection CAN, Ethernet
Input/output interfaces Ethernet, 2xCAN, EIB, Bluetooth
Data speed 10/100Mb/s
Max CAN deviсes 100(50 per CAN)
CAN bus topology BUS
Number of CAN ports 2
Power supply 11.5 … 27.5 V DC
24V, 2.5A Recommended
Max own current (24V) 140mA
Max CAN bus length 800 m* (twisted pair 5 cat)
Max current per CAN bus 700mA
IR Receiver angle 30°
Case material ABS
Protection IP40
Equipment installation type DIN-rail (EN 60715)
Temperature range -10 … +50°C
Size 6U, 104x90x58 mm
Weight 145 g

* – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors

Indication of module operation

Indicator Status Description
Power Gl.png Power
E.png Power not available
Activity Y.png Data communication
E.png Data communication not available
Error E.png No errors
Rl.png Overheating
R.pngR.png No connection to AC.
R.pngR.pngR.pngDots.png The data has not been transferred via the CAN bus for at least 5 minutes.
R.pngR.pngR.pngDots.png No power on the lamp.
R.pngR.pngR.pngDots.png No power on the DALI bus or over current (more then 180 mA) on DALI bus. If over current is at both bus blinking twice in half a second.