Difference between revisions of "FW-FT/ru"
Jump to navigation
Jump to search
(Created page with "FW-FT") |
(No difference)
|
Revision as of 13:05, 10 January 2022
FW-FT | |||||||
---|---|---|---|---|---|---|---|
| |||||||
|
UNDERFLOOR HEATING TEMPERATURE SENSOR
This is an underfloor heating temperature sensor for DW-HCxx, it can also be used to measure the outdoor temperature.
Pin assignments
Example of connection
Example of connection
Module parameters
Parameter name | Value |
---|---|
Control parameters | Temperature |
Temperature measuring range | -20 … +60°C |
Power supply | 5 V DC |
Max current | 5 mA |
Sensor cable length | 3m |
Sensors line max length | 30 m* |
Bus type | One Wire |
Equipment installation type | Built into the floor/outdoor |
Case material | ABS |
Protection | IP65 |
Temperature range | -20 … +60 °C |
Size | 8x8x50 mm |
Weight | 15g |
* - +5V and COM should be connected in one twisted pair, and DATA at free one
HW settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
offset | float (+/- 0…39) | SubID of sensor | 0 | sensor values offset (for temperature sensors) Example:
1hw="offset='-3'"
|