Difference between revisions of "Ventilation/en"
Jump to navigation
Jump to search
(Updating to match new version of source page) |
(No difference)
|
Latest revision as of 15:15, 24 January 2022
Ventilation
Example of description in XML
1<item addr="345:123" length="6" name="Ventilation" sub-type="ventilation" type="virtual"/>
2// Ventilation virtual device description
3<import-script id="345" VENT="80" RS485="345:12" path="vent.txt"/> // Ventilation control script description
Additional parameters
Name | type and variety | description | default value |
---|---|---|---|
sub-type* | string, ventilation | subtype | ventilation |
funs | bit mask | Mask of airflow mode | 0xFF |
* – required fields
Device status (6 bytes)
Byte number | Description |
---|---|
0 | 0 bit – 0 is off, 1 is on |
1 | 0-3d bit – temperature (+16 is to be added to the value) |
4 | 0-3d bit – airflow capacity |
Status setting
from the 1st to the 6th correspondingly