!Name!!type and variety!!description!!default value
|-
|temperature-sensors||list||list of valve temperature sensors (for automation) || -
|-
|automation||string||name of current automation mode||-
|-
|sub-type||enum||warm-floor||-
|-
|temperature-lag||number||hysteresis range on either side from set-point temperature Set in automation tag. The decimal symbol is dot.||0.5
|-
|undefined-behavior||enum<br>on/off/last||valve position in case of sensors readings absence||last
|-
|sensor-cr||list||temperature-sensor measuring the maximum and minimum critical temperature||-
|-
|sensor-cr-hi||number||upper temperature limit, to disable warm floor in case of overheating||-
|-
|sensor-cr-lo||number||lower temperature limit, to activate the warm floor in case of overcooling.||-
|-
|t-min||number||lower temperature limit to set||0
|-
|t-max||number||upper temperature limit to set||32
|}