Example of description in XML

1<item type="intercom" addr="161:250" name="Intercom" iid="2009;2019" cameras="2048:55;2048:56" door="333:6">

Additional parameters

Name type and variety description default value
cameras string
ADDR[;ADDR]
list of cameras addresses displayed when intercom calls -
door ADDR The address of a device responsible for door opening -
iid ID Intercom will be call on device or devices with his ID 2047(broadcast)

Device status (1 byte)

Byte number description
0 0 – no call (event – timing out call drop or the button "Finish" or "Cancel" is pressed).
1 – button "answer" is pressed
2 – intercom calls (repeat every second until timing out call drop or the button "Finish" or "Cancel" is pressed).

Status setting (1 byte)

Byte number description
0 0 – Cancel Call
1 – intercom calls
8 – Screenshot from IC camera (and save it to History)