Difference between revisions of "DW-HT07/ru"

From Larnitech wiki page
Jump to navigation Jump to search
(Created page with "==Установки HW==")
 
(3 intermediate revisions by the same user not shown)
Line 35: Line 35:
 
**Герконами
 
**Герконами
 
**Датчиками протечки
 
**Датчиками протечки
**Детекторами движения
+
**Датчиками движения
 
*4 цифровых входа для 8 датчиков температуры
 
*4 цифровых входа для 8 датчиков температуры
  
Line 205: Line 205:
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
!Name!!Type, range!!SUBID!!Default!!Description
+
!Название!!Тип, диапазон!!SUBID!!По умолчанию!! Описание
 
|-
 
|-
|runtime||integer 0-100||1-7||15||runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15
+
|runtime ||целое число 0-100||1-10||15||runtime - время открытия/закрытия в секундах, используется для жалюзи, ворот, клапана (2-х полюсного);  
 +
<br>Пример: runtime = 15
 
|-
 
|-
|runtimeopen||integer 0-60000||Blinds subId||-||Runtimeopen is the open time in milliseconds, is used for blinds; Example: runtimeopen=15000
+
|runtimeopen||целое число 0-60000||Жалюзи subId|| || Runtimeopen - время открытия в миллисекундах, используется для жалюзи; Пример: runtimeopen = 15000
 
|-
 
|-
|runtimeclose||integer 0-60000||Blinds subId||-||Runtimeclose is the close time in milliseconds, is used for blinds; Example: runtimeclose=15000
+
|runtimeclose||целое число 0-60000||Жалюзи subId|| ||Runtimeclose - время закрытия в миллисекундах, используется для жалюзи; Пример: runtimeclose = 15000
 
|-
 
|-
|hold||integer 0-10000||1-7||500||hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500
+
|hold||целое число 0-10000||1-10 || 500|| hold - время переключения в миллисекундах, используется для ворот и жалюзи (по умолчанию hold совпадает с временем выполнения), замков; Пример: hold = 3500
 
|-
 
|-
|def||string 'ON'||1-7||'OFF'||def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
+
|def||строка'ON'||1-18||'OFF'||def - состояние элемента, которое устанавливается после перезапуска, используется для освещения, отопления, клапана (1-но полюсного); Пример: def = 'ON'
 
|-
 
|-
|stop||Char ‘R’||1-7||–||(for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is ‘r’ or ‘R’ then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., ‘d’ ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop=’r’
+
|stop||символ ‘R’||1-17||–||(для двухполюсных ворот и жалюзи). Если данная установка введена командой Stop во время движения, то появляется тот же импульс, что и в начале движения. Полюс, на котором формируются импульсы остановки, определяется параметром Stop value. Если это «r» или «R», то импульс остановки вырабатывается на противоположной стороне полюса импульса запуска. Если указано любое другое значение (например, «d»), то импульс остановки находится на том же полюсе. Если после начала движения прошло Runtime, то импульс остановки не формируется. Пример: stop=’r’'
 
|-
 
|-
|out||char[7]||98||'LLLLLLL'||Each char is responsible for the type of a particular channel
+
|out||символ[7]||98||'LLLLLLL'||Каждый символ отвечает за тип конкретного канала
*'L'-Lamp;
+
*'L'-Освещение;
*'M'-Lamp Inverse;
+
*'M'-Освещение (инверсия);
*'J'-Heating NO, valve-heating, normally open;
+
*'J'-Отопление NO, клапан отопления, обычно открыт;
*'H'-Heating NC, valve-heating, normally closed;
+
*'H'-Отопление NC, клапан отопления, обычно закрыт;
*'B'-Blinds, jalousie/curtains(2 pole);
+
*'B'-Жалюзи (2-х полюсные), жалюзи/шторы;
*'C'-Blinds Inverse, jalousie/curtains, invert open-close(2 pole);
+
*'C'-Жалюзи (2-х полюсные) (инверсия), жалюзи/шторы, инверсия открытия-закрытия;
*'G'-Gate (2 pole), 2 pole gate;
+
*'G'-Ворота (2-х полюсные), 2-х полюсные ворота;
*'D'-Gate (2 pole) Inverse, 2 pole gate, invert open-close;
+
*'D'-Ворота (2-х полюсные) (инверсия), 2-х полюсные ворота, инверсия открытия-закрытия;
*'X'-Gate (1 pole /short press), 1 pole gate;
+
*'X'-Ворота (1-полюсные/короткое нажатие), 1-полюсные ворота;
*'Z'-Gate (1 pole) Inverse, 1 pole gate, invert open-close;
+
*'Z'-Ворота (1-полюсные) (инверсия), 1-полюсные ворота, инверсия открытия-закрытия;
*'V'-Valve (2 pole), 2 pole valve;
+
*'V'-Клапан (2-полюсный), 2-полюсный клапан;
*'W'-Valve (2 pole) Inverse, 2 pole valve, invert open-close;
+
*'W'-Клапан (2-полюсный)(инверсия), 2-полюсный клапан, инверсия открытия-закрытия;
*'R'-Valve (1 pole), 1 pole valve,;
+
*'R'-Клапан (1-полюсный), 1-полюсный клапан;
*'S'-Valve (1 pole) Inverse, 1 pole valve, invert open-close;
+
*'S'-Клапан (1-полюсный) (инверсия), 1-полюсный клапан, инверсия открытия-закрытия;
*'K'-Lock (short press);
+
*'K'-Замок (короткое нажатие);
*'N'-Lock (short press) Inverse;
+
*'N'-Замок (короткое нажатие) (инверсия);
*'F'-FanCoil. Group1 (Lamp Toggle). For fancoil speed control;
+
*'F'-Фанкойл. Группа1 (Переключатель освещения). Для управления скоростью фанкойла;
*'E'-FanCoil. Group2 (Lamp Toggle). For fancoil speed control;
+
*'E'-Фанкойл. Группа2 (Переключатель освещения). Для управления скоростью фанкойла;
*'Q'-FanCoil. Group3 (Lamp Toggle). For fancoil speed control;
+
*'Q'-Фанкойл. Группа3 (Переключатель освещения). Для управления скоростью фанкойла;
*'U'-FanCoil. Group4 (Lamp Toggle). For fancoil speed control;
+
*'U'-Фанкойл. Группа4 (Переключатель освещения). Для управления скоростью фанкойла;
*'I'-FanCoil. Group5 (Lamp Toggle). For fancoil speed control;
+
*'I'-Фанкойл. Группа5 (Переключатель освещения). Для управления скоростью фанкойла;
*'-'-none, nothing is connected.
+
*'-'-элементы отсутствуют, ничего не подключено.
Example: out='LLHHHG-'
+
Пример: out='LLHHHG-'
 
|-
 
|-
|offset||float||SubID of OW temperature sensors||'0'||[+/- 0..39] – sensor values offset;
+
|offset||переменная||SubID датчиков температуры OW||'0'||[+/- 0..39] – смещение значений датчика;
For example, offset is -3.8 : hw="offset='-3.8'"
+
Например, смещение составляет -3.8 : hw="offset='-3.8'"
 
|-
 
|-
|in||char[12]||98||'KKKKKKKKKKKK'||Each char is responsible for the type of a particular channel
+
|in||символ[12]||98||'KKKKKKKKKKKK'||Каждый символ отвечает за тип конкретного канала
*'B'-Button;
+
*'B'-Кнопка;
*'C'-Inverted button;
+
*'C'-nКнопка;
*'S'-Switch;
+
*'S'-Выключатель;
*'K'-Contact;
+
* 'K'-Контакт;
*'H'-Inverted contact;
+
* 'H'-nКонтакт;
*'L'-Leak, Built-in floor (EW-WL) or on-the-floor (FW-WL) leakage sensor
+
*‘L’-Протечка, встроенный в пол (EW-WL) или напольный (FW-WL) датчик протечки
*'N'-Third party leakage sensor;
+
*‘N’-датчик протечки другого производителя;
*'M'-Motion, ​motion sensor;
+
* 'M'-Движение, датчик движения;
*'-'-none
+
*'-'-элементы отсутствуют
Example: in='KKKBBBLLLMMM'
+
Пример: in='KKKBBBLLLMMM'
 
|}
 
|}
  

Latest revision as of 12:57, 29 January 2022

Other languages:
English • ‎русский
Revision:
/B
/C


DW-HT07.C
DW-HT07C.png
Output ports
Number of switched channels7
Peak load16A
Input ports
Number of discrete inputs12
Number of digital inputs4
Other
Supply voltage11.5...27.5 V DC
Dimentions4U, 69x115x58 mm


7-МИ КАНАЛЬНЫЙ МОДУЛЬ РАСШИРЕНИЯ

Снабжен 7-ю выходами для подключения нагрузки и 12-ю входами для подключения различных датчиков/кнопок.

Функции

  • 7 универсальных выходов обеспечивают управление:
    • Освещением
    • Клапанами отопления NC/NO
    • Жалюзи
    • 1- или 2-х полюсными воротами
    • 1- или 2-х полюсными клапанами
    • Замками NC/NO
    • Фанкойлами
  • 12 отдельных входов обеспечивают управление:
    • Кнопками
    • Выключателями
    • Герконами
    • Датчиками протечки
    • Датчиками движения
  • 4 цифровых входа для 8 датчиков температуры

ВНИМАНИЕ! Все работы, связанные с установкой, подключением, настройкой, обслуживанием и поддержкой, должны выполняться квалифицированным персоналом, имеющим достаточные навыки и опыт работы с электрооборудованием. Во избежание риска возгорания, поражения электрическим током, повреждения системы и/или травм, установка и сборка системы должны выполняться в соответствии с инструкциями, перечисленными ниже:

  • все работы по подключению должны производиться на обесточенном оборудовании;
  • необходимо использовать соответствующие инструменты и средства индивидуальной защиты от поражения электрическим током;
  • запрещается использовать поврежденные кабели, провода и разъемы;
  • избегайте перегиба проводов и кабелей;
  • не пережимайте и не перегибайте кабели и провода, прилагая чрезмерные усилия. В противном случае внутренние проводники кабеля и проводов могут быть оголены или повреждены;
  • не используйте для подключения разъемы с плохими контактами;
  • не превышайте предельные параметры нагрузки, указанные в данном руководстве;
  • сечение питающих проводов зависит от требований к пределу плотности тока, типу изоляции и материалу проводов. Недостаточное сечение может привести к перегреву кабеля и возгоранию.

При работе с системой после подачи напряжения НИКОГДА:

  • не производите подключение/отключение разъемов;
  • не открывайте модули и датчики.

Общая схема модуля

HT07C VIEW.png

Пример подключения

HT07C EXA.png

Размеры модуля

HT07 DIMM.png

Параметры модуля

Parameter name Value
Input channels qty
Input/output channels qty
0-10 input port quantity
Buttons
LED Buttons
Number of sensor inputs
Number of dry contact inputs
RS485 ports qty
RS232 ports qty
UART ports qty
M-BUS port quantity
Pulse inputs quantity
DALI ports qty
DALI-line voltage supply
Peak current of DALI-line power supply
Peak current in DALI-line
Maximum DALI devices quantity
Dimming channels qty
Output channels qty 7
0-10 output port quantity
Analog output channels qty
Output
Digital line maximum length 30 m
Discrete input channels qty 12
Digital input channels qty 4
Speakers
Max power output audio channel
Camera
IR lighting
Card reader
Connection type
Protocols
Backlight voltage
Load type
Dimmer load type
Supported sensors
Input voltage 0-250V
Current type AC/DC
Adjustment type
Max load
Min load
Max load per channel 16A
Max load per group
Max load per device
Control parameters
Angle of vision IR °
Angle of motion °
Temperature measuring range °C
Humidity measuring range
Dimmer type
Dimming type
Voltage that may be applied to the input channels 0-250V
Max output switching voltage
Max output switching current
Power supply 20.0 … 27.5 V DC from CAN
Max current(24V) 140 mA
Max current(13V)
Max detection distance
Max IR distance
Max BT distance
Max current
Relay
Data transfer speed
Permissible section of power supply cable to connect in socket:
Sensors VCC output
Sensors max VCC current
R1-R2 inputs max current
Push-button/reed switches line recommended length
Temperature sensor line max length
Sensor cable length
Sensors line max length
Bus type CAN
Compatible with
Output voltage
Output current
Equipment installation type DIN rail (EN 60715)
Mounting
Max cabel lenght
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 4U, 69x115x58 mm
Weight 255 g
* -
** -
*** -
1 -
2 -
3 -


Рекомендации по подключению

Для защиты реле и подключенных к нему нагрузок рекомендуется установить автоматический выключатель. Номинальное значение автоматического выключателя следует рассчитывать исходя из максимальной общей нагрузки подключенных устройств, и при этом оно не должно значительно превышать максимально допустимые характеристики реле. В зависимости от требований вы можете использовать один автоматический выключатель на одно реле (рекомендуется) или один автоматический выключатель на каждую группу подключенных нагрузок, или, при необходимости, можно установить отдельный автоматический выключатель для каждой нагрузки.

Подключение реле

Внимание: Перед подачей питания на модуль необходимо правильно настроить выходы в приложении. Неправильно настроенные контакты могут привести к одновременной подаче питания на оба канала, что приведет к выходу модуля из строя и/или отказу подключенного к нему оборудования, и даже к возгоранию. Если в данной группе после подключения к ней привода штор/жалюзи/ставней с низковольтным управлением или привода ворот остаются свободные (неиспользуемые) каналы, то эти каналы необходимо оставить неиспользованными. (Не подключайте к ним другие устройства!)

Подключение освещения/электрического контактора/термореле отопления

Lamps.png
Пример HW для этой конфигурации

1hw="out='LLL----'"


Подключение устройства с высокой нагрузкой

Contactor Рекомендуемые контакторы:
  • ABB серии ESB
  • Schneider Acti 9 серии iCT
  • Hager серии ESC.

Подключение привода штор/жалюзи/ставней с регулировкой усилия 220 В

Pjalousie.png
Пример HW для этой конфигурации

1hw="out='B------'"

Подключение привода штор/жалюзи/ставней с низковольтным управлением

Ljalousie.png
Пример HW для этой конфигурации

1hw="out='B------'"

Подключение однополюсного привода ворот

1pgate.png
Пример HW для этой конфигурации

1hw="out='X------'"

Подключение двухполюсного привода ворот

2pgate.png
Пример HW для этой конфигурации

1hw="out='G------'"


Подключение однополюсного клапана подачи воды/газа

1pvalve.png
Пример HW для этой конфигурации

1hw="out='R------'"

Подключение двухполюсного клапана подачи воды/газа

2pvalve.png
Пример HW для этой конфигурации

1hw="out='V------'"

Подключение блока управления фанкойлом

Fancoil.png
Пример HW для этой конфигурации

1hw="out='FFF----'"

Пример подключения датчиков

SensorsCon4.png
Рекомендуется использовать 2-х проводное подключение

Индикация работы модуля

Загрузчик

Indicator Status Description
Top.png
Yl.png Device in bootloader
Bot.png
B.pngB.png Downloading firmware
R.pngR.png Flashing firmware

Прошивка

Indicator Status Description
Top.png
G.pngG.pngG.pngDots.png Network configuration
B.pngB.pngB.pngDots.png Identification
Gl.png Operational mode
Yl.png Operational mode
Bot.png

Error
R.png Lost connection to server
R.pngR.png Overheat
R.pngR.pngR.png Overload
R.pngR.pngR.pngR.png No AC power
R.pngR.pngR.pngR.pngR.png RTC error
Bot.png

Activity
Y.png CAN activity
Bg.png OW activity
M.png RS-485 activity
B.png Ethernet activity


Порядок установки и подключения модуля

  1. Подключите выходы.
  2. Подключите входы.
  3. Подключите коннектор шины CAN.
  4. Настройте модуль с помощью LT SETUP.
  5. Подайте питание на нагрузку.
  6. Проверьте все оборудование на правильность работы.

Отключение модуля и процедура демонтажа

  1. Отключите питание от нагрузки.
  2. Отсоедините коннектор CAN.
  3. Отсоедините входы.
  4. Отсоедините выходы.

Установки HW

Название Тип, диапазон SUBID По умолчанию Описание
runtime целое число 0-100 1-10 15 runtime - время открытия/закрытия в секундах, используется для жалюзи, ворот, клапана (2-х полюсного);


Пример: runtime = 15

runtimeopen целое число 0-60000 Жалюзи subId Runtimeopen - время открытия в миллисекундах, используется для жалюзи; Пример: runtimeopen = 15000
runtimeclose целое число 0-60000 Жалюзи subId Runtimeclose - время закрытия в миллисекундах, используется для жалюзи; Пример: runtimeclose = 15000
hold целое число 0-10000 1-10 500 hold - время переключения в миллисекундах, используется для ворот и жалюзи (по умолчанию hold совпадает с временем выполнения), замков; Пример: hold = 3500
def строка'ON' 1-18 'OFF' def - состояние элемента, которое устанавливается после перезапуска, используется для освещения, отопления, клапана (1-но полюсного); Пример: def = 'ON'
stop символ ‘R’ 1-17 (для двухполюсных ворот и жалюзи). Если данная установка введена командой Stop во время движения, то появляется тот же импульс, что и в начале движения. Полюс, на котором формируются импульсы остановки, определяется параметром Stop value. Если это «r» или «R», то импульс остановки вырабатывается на противоположной стороне полюса импульса запуска. Если указано любое другое значение (например, «d»), то импульс остановки находится на том же полюсе. Если после начала движения прошло Runtime, то импульс остановки не формируется. Пример: stop=’r’'
out символ[7] 98 'LLLLLLL' Каждый символ отвечает за тип конкретного канала
  • 'L'-Освещение;
  • 'M'-Освещение (инверсия);
  • 'J'-Отопление NO, клапан отопления, обычно открыт;
  • 'H'-Отопление NC, клапан отопления, обычно закрыт;
  • 'B'-Жалюзи (2-х полюсные), жалюзи/шторы;
  • 'C'-Жалюзи (2-х полюсные) (инверсия), жалюзи/шторы, инверсия открытия-закрытия;
  • 'G'-Ворота (2-х полюсные), 2-х полюсные ворота;
  • 'D'-Ворота (2-х полюсные) (инверсия), 2-х полюсные ворота, инверсия открытия-закрытия;
  • 'X'-Ворота (1-полюсные/короткое нажатие), 1-полюсные ворота;
  • 'Z'-Ворота (1-полюсные) (инверсия), 1-полюсные ворота, инверсия открытия-закрытия;
  • 'V'-Клапан (2-полюсный), 2-полюсный клапан;
  • 'W'-Клапан (2-полюсный)(инверсия), 2-полюсный клапан, инверсия открытия-закрытия;
  • 'R'-Клапан (1-полюсный), 1-полюсный клапан;
  • 'S'-Клапан (1-полюсный) (инверсия), 1-полюсный клапан, инверсия открытия-закрытия;
  • 'K'-Замок (короткое нажатие);
  • 'N'-Замок (короткое нажатие) (инверсия);
  • 'F'-Фанкойл. Группа1 (Переключатель освещения). Для управления скоростью фанкойла;
  • 'E'-Фанкойл. Группа2 (Переключатель освещения). Для управления скоростью фанкойла;
  • 'Q'-Фанкойл. Группа3 (Переключатель освещения). Для управления скоростью фанкойла;
  • 'U'-Фанкойл. Группа4 (Переключатель освещения). Для управления скоростью фанкойла;
  • 'I'-Фанкойл. Группа5 (Переключатель освещения). Для управления скоростью фанкойла;
  • '-'-элементы отсутствуют, ничего не подключено.

Пример: out='LLHHHG-'

offset переменная SubID датчиков температуры OW '0' [+/- 0..39] – смещение значений датчика;

Например, смещение составляет -3.8 : hw="offset='-3.8'"

in символ[12] 98 'KKKKKKKKKKKK' Каждый символ отвечает за тип конкретного канала
  • 'B'-Кнопка;
  • 'C'-nКнопка;
  • 'S'-Выключатель;
  • 'K'-Контакт;
  • 'H'-nКонтакт;
  • ‘L’-Протечка, встроенный в пол (EW-WL) или напольный (FW-WL) датчик протечки
  • ‘N’-датчик протечки другого производителя;
  • 'M'-Движение, датчик движения;
  • '-'-элементы отсутствуют

Пример: in='KKKBBBLLLMMM'

 1<item addr="479:1" auto-period="600" cfgid="42" name="Lamp" type="lamp" uniq_id="145" hw="def='ON'"/>
 2<item addr="479:2" cfgid="42" name="Radiator" type="valve-heating" uniq_id="146" hw="def='ON'">
 3  <automation name="Eco" temperature-level="16" uniq_id="147"/>
 4  <automation name="Comfort" temperature-level="22" uniq_id="148"/>
 5  <automation name="Hot" temperature-level="25" uniq_id="149"/>
 6</item>
 7<item addr="479:3" cfgid="42" name="Gate" sub-type="120" type="gate" uniq_id="150" hw="runtime=25"/>
 8<item addr="479:5" cfgid="42" name="Jalousie" sub-type="120" type="jalousie" uniq_id="151" hw="runtime=50"/>
 9<item addr="479:7" cfgid="42" name="Valve" type="valve" uniq_id="152" hw="def='ON'"/>
10<item addr="479:11" cfgid="42" name="Switch" type="switch" uniq_id="153"/>
11<item addr="479:12" cfgid="42" name="Switch" type="switch" uniq_id="154"/>
12<item addr="479:13" cfgid="42" name="Door" type="door-sensor" uniq_id="133"/>
13<item addr="479:14" cfgid="42" name="Door" type="door-sensor" uniq_id="134"/>
14<item addr="479:15" cfgid="42" name="Leak" type="leak-sensor" uniq_id="155"/>
15<item addr="479:16" cfgid="42" name="Leak" type="leak-sensor" uniq_id="156"/>
16<item addr="479:17" cfgid="42" name="Motion" type="motion-sensor" uniq_id="157"/>
17<item addr="479:18" cfgid="42" name="Door" type="door-sensor" uniq_id="138"/>
18<item addr="479:20" cfgid="42" name="Door" type="door-sensor" uniq_id="140"/>
19<item addr="479:21" cfgid="42" name="Motion" type="motion-sensor" uniq_id="158"/>
20<item addr="479:97" cfgid="42" name="Temperature" system="yes" type="temperature-sensor" uniq_id="143"/>
21<item addr="479:98" cfgid="42" hw="out='LHG-B-R' in='CSKHLNMK-KM-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="144"/>