− | ==6-CHANNEL INPUT MODULE== | + | ==6-CHANNEL INPUT MODULE== <!--T:2--> |
+ | <!--T:3--> | ||
This module is used to connect buttons/reed switches. | This module is used to connect buttons/reed switches. | ||
− | ==Features== | + | ==Features== <!--T:4--> |
*5 inputs support: | *5 inputs support: | ||
**Buttons | **Buttons | ||
Line 22: | Line 26: | ||
**Digital temperature sensor | **Digital temperature sensor | ||
− | ==Example of connection== | + | ==Example of connection== <!--T:5--> |
+ | <!--T:6--> | ||
[[File:SW06C EXA.png|500px]] | [[File:SW06C EXA.png|500px]] | ||
<br> | <br> | ||
Line 29: | Line 34: | ||
[[File:SW06C EXA2.jpg|500px]] | [[File:SW06C EXA2.jpg|500px]] | ||
− | ==Module parameters== | + | ==Module parameters== <!--T:7--> |
+ | <!--T:8--> | ||
{{ Mp | {{ Mp | ||
| inqty = 6 | | inqty = 6 | ||
Line 48: | Line 54: | ||
}} | }} | ||
− | ==Module installation and connection procedure== | + | ==Module installation and connection procedure== <!--T:9--> |
+ | <!--T:10--> | ||
#Connect the inputs. | #Connect the inputs. | ||
#Connect the CAN connector. | #Connect the CAN connector. | ||
Line 55: | Line 62: | ||
#Check all equipment for proper operation. | #Check all equipment for proper operation. | ||
− | ==Module shut-off and deinstallation procedure== | + | ==Module shut-off and deinstallation procedure== <!--T:11--> |
+ | <!--T:12--> | ||
#Disconnect the CAN connector. | #Disconnect the CAN connector. | ||
#Disconnect the inputs. | #Disconnect the inputs. | ||
− | ==HW settings== | + | ==HW settings== <!--T:13--> |
{|class="wikitable" | {|class="wikitable" | ||
|- | |- | ||
Line 77: | Line 85: | ||
*'-'-none, nothing is connected. | *'-'-none, nothing is connected. | ||
And you can also connect one temperature sensor: | And you can also connect one temperature sensor: | ||
− | <syntaxhighlight lang="xml" line>hw="in='T | + | <syntaxhighlight lang="xml" line>hw="in='T-----'"</syntaxhighlight> |
− | <syntaxhighlight lang="xml" line>Example: in='DEHSSG' | + | <syntaxhighlight lang="xml" line>Example: in='DEHSSG'</syntaxhighlight> |
|- | |- | ||
|offset||float(+/- 0…39)||SubID 30 temperature sensor||'0'||sensor values offset; | |offset||float(+/- 0…39)||SubID 30 temperature sensor||'0'||sensor values offset; | ||
For example, offset is -3.8 : | For example, offset is -3.8 : | ||
− | <syntaxhighlight lang="xml" line>hw="offset='-3.8'" | + | <syntaxhighlight lang="xml" line>hw="offset='-3.8'"</syntaxhighlight> |
|} | |} | ||
− | ==Input HW configuration== | + | ==Input HW configuration== <!--T:14--> |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 97: | Line 105: | ||
|} | |} | ||
+ | <!--T:15--> | ||
<syntaxhighlight lang="xml" line> | <syntaxhighlight lang="xml" line> | ||
<item addr="477:13" cfgid="180" name="Switch" type="switch" uniq_id="78"/> | <item addr="477:13" cfgid="180" name="Switch" type="switch" uniq_id="78"/> | ||
Line 104: | Line 113: | ||
<item addr="477:98" cfgid="180" hw="in='T+DD-H'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="76"/> | <item addr="477:98" cfgid="180" hw="in='T+DD-H'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="76"/> | ||
</syntaxhighlight> | </syntaxhighlight> | ||
+ | </translate> |
Latest revision as of 12:35, 9 January 2022
BW-SW06.C | |||||||||
---|---|---|---|---|---|---|---|---|---|
| |||||||||
|
6-CHANNEL INPUT MODULE
This module is used to connect buttons/reed switches.
Features
- 5 inputs support:
- Buttons
- Switches
- Reed switches
- LED buttons
- Digital temperature sensor
Example of connection
Module parameters
Parameter name | Value |
---|---|
Input channels qty | 6 |
Buttons | 6 |
LED Buttons | 5 |
Backlight voltage | 3V |
Power supply | 11.5 … 27.5 V DC from CAN |
Max current(24V) | 30 mA |
Temperature sensor line max length | 10m |
Bus type | CAN (4-wire) |
Equipment installation type | Free |
Case material | ABS |
Protection | IP40 |
Temperature range | -10 … +50 °C |
Size | 45x42x14 mm |
Weight | 25 g |
Module installation and connection procedure
- Connect the inputs.
- Connect the CAN connector.
- Configure the module using LT setup.
- Check all equipment for proper operation.
Module shut-off and deinstallation procedure
- Disconnect the CAN connector.
- Disconnect the inputs.
HW settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
in | char[16] | 98 | 'BBBBBB' | Each char is responsible for the type of a particular channel
And you can also connect one temperature sensor: 1hw="in='T-----'"
1Example: in='DEHSSG'
|
offset | float(+/- 0…39) | SubID 30 temperature sensor | '0' | sensor values offset;
For example, offset is -3.8 : 1hw="offset='-3.8'"
|
Input HW configuration
chanel | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
Button nButton Switch Contact nContact none |
+ | + | + | + | + | + |
LedButton nLedButton |
+ | + | + | + | + | |
Temperature Sensor | + |
1<item addr="477:13" cfgid="180" name="Switch" type="switch" uniq_id="78"/>
2<item addr="477:14" cfgid="180" name="Switch" type="switch" uniq_id="79"/>
3<item addr="477:16" cfgid="180" name="Door" type="door-sensor" uniq_id="80"/>
4<item addr="477:30" cfgid="180" hw="offset='15'" name="Temperature" type="temperature-sensor" uniq_id="83"/>
5<item addr="477:98" cfgid="180" hw="in='T+DD-H'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="76"/>