{{RevisionChanger | hasA = 1 | hasC = 1}}
 +
{{Infobox module
 +
| name      = BW-LC02.C
 +
| image      = BW-LC02C.png
 +
| outCount  = 2
 +
| peakl      = 2A
 +
| inCount    = 6
 +
| inB        = 6
 +
| inLB      = 5
 +
| voltage    = 11.5...27.5 V DC
 +
| dim        = 45x42x14 mm
 +
}}
  
==2-CHANNEL ACTUATOR==
+
==2-CHANNEL ACTUATOR== <!--T:2-->
  
 +
<!--T:3-->
 
Designed for AC/DC circuits commutation. Applicable for lighting and
 
Designed for AC/DC circuits commutation. Applicable for lighting and
 
other electrical devices. It has 6 inputs for connecting buttons and reed switches.
 
other electrical devices. It has 6 inputs for connecting buttons and reed switches.
  
==Features==
+
==Features== <!--T:4-->
 
*Compact size (only 16mm thickness)
 
*Compact size (only 16mm thickness)
 
*6 inputs support:
 
*6 inputs support:
Line 18: Line 34:
 
**NC/NO locks
 
**NC/NO locks
 
**Blinds
 
**Blinds
 +
**Сurtains
 +
**Projector screens
 +
**Valves
  
 +
WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings
 +
 +
<!--T:5-->
 
<div class="caution">
 
<div class="caution">
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
 
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.
Line 35: Line 57:
 
</div>
 
</div>
  
==Example of connection==
+
==Example of connection== <!--T:6-->
  
 +
<!--T:7-->
 
[[File:LC02C EXA.png|700px]]
 
[[File:LC02C EXA.png|700px]]
 
<br>
 
<br>
Line 42: Line 65:
 
[[File:LC02C OUT.png|400px]]
 
[[File:LC02C OUT.png|400px]]
  
==Module parameters==
+
==Module parameters== <!--T:8-->
  
 +
<!--T:9-->
 
{{ Mp
 
{{ Mp
 
| outqty          = 2
 
| outqty          = 2
Line 49: Line 73:
 
| buttons        = 6
 
| buttons        = 6
 
| ledbuttons      = 5
 
| ledbuttons      = 5
| involtage      = 100-250V
+
| involtage      = 0-250V
 
| currtype        = AC/DC
 
| currtype        = AC/DC
 
| maxperch        = 2A
 
| maxperch        = 2A
Line 64: Line 88:
 
| protection      = IP40
 
| protection      = IP40
 
| temprange      = -10 … +50 °C
 
| temprange      = -10 … +50 °C
| size            = 4U, 69x115x58 mm
+
| size            = 45x42x14 mm
| weight          = 180 g
+
| weight          = 25 g
 
}}
 
}}
  
==Module installation and connection procedure==
+
==Module installation and connection procedure== <!--T:10-->
  
 +
<!--T:11-->
 
#Connect the outputs.
 
#Connect the outputs.
 
#Connect the inputs.
 
#Connect the inputs.
Line 77: Line 102:
 
#Check all equipment for proper operation.
 
#Check all equipment for proper operation.
  
==Module shut-off and deinstallation procedure==
+
==Module shut-off and deinstallation procedure== <!--T:12-->
  
 +
<!--T:13-->
 
#Disconnect the power from the load.
 
#Disconnect the power from the load.
 
#Disconnect the CAN connector.
 
#Disconnect the CAN connector.
Line 84: Line 110:
 
#Disconnect the outputs.
 
#Disconnect the outputs.
  
==HW settings==
+
==HW settings== <!--T:14-->
 
{|class="wikitable"
 
{|class="wikitable"
 
|-
 
|-
Line 122: Line 148:
 
*'K'-Lock (short press),
 
*'K'-Lock (short press),
 
*'N'-Lock (short press) Inverse,
 
*'N'-Lock (short press) Inverse,
 +
 +
WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings
 +
*'Y'-Low-current lamp,
 +
*'T'-Low-current lamp Inverse,
 
*'F'-Low-current blinds,
 
*'F'-Low-current blinds,
 
*'A'-Low-current blinds Inverse,
 
*'A'-Low-current blinds Inverse,
Line 153: Line 183:
 
|}
 
|}
  
==Input HW configuration==
+
==Input HW configuration== <!--T:15-->
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 165: Line 195:
 
|}
 
|}
  
 +
<!--T:16-->
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
<item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/>
 
<item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/>
Line 173: Line 204:
 
<item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>
 
<item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>
 
</syntaxhighlight>
 
</syntaxhighlight>
 +
</translate>

Latest revision as of 12:28, 3 March 2023

Other languages:
English • ‎русский
Revision:
/B
/C


BW-LC02.C
BW-LC02C.png
Output ports
Number of switched channels2
Peak load2A
Input ports
Number of inputs6
Number of buttons6
Number of LED buttons5
Other
Supply voltage11.5...27.5 V DC
Dimentions45x42x14 mm


2-CHANNEL ACTUATOR

Designed for AC/DC circuits commutation. Applicable for lighting and other electrical devices. It has 6 inputs for connecting buttons and reed switches.

Features

  • Compact size (only 16mm thickness)
  • 6 inputs support:
    • Buttons
    • Switches
    • reed switches
    • LED buttons
    • digital temperature sensor
  • Outputs support:
    • Lights
    • NC/NO heating valves
    • NC/NO locks
    • Blinds
    • Сurtains
    • Projector screens
    • Valves

WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings

CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:

  • all connectivity work must be carried out with the power turned OFF;
  • use appropriate tools and personal protection against electric shock;
  • do not use damaged cables, wires and connectors;
  • avoid folding the cables and wires;
  • do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
  • do not use the power socket with poor contacts to connect;
  • do not exceed the load limit parameters specified in the manual;
  • the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.

When the power is on, NEVER:

  • connect/disconnect the connectors;
  • open modules and sensors.

Example of connection

LC02C EXA.png

LC02C OUT.png

Module parameters

Parameter name Value
Input channels qty 6
Input/output channels qty
0-10 input port quantity
Buttons 6
LED Buttons 5
Number of sensor inputs
Number of dry contact inputs
RS485 ports qty
RS232 ports qty
UART ports qty
M-BUS port quantity
Pulse inputs quantity
DALI ports qty
DALI-line voltage supply
Peak current of DALI-line power supply
Peak current in DALI-line
Maximum DALI devices quantity
Dimming channels qty
Output channels qty 2
0-10 output port quantity
Analog output channels qty
Output
Digital line maximum length
Discrete input channels qty
Digital input channels qty
Speakers
Max power output audio channel
Camera
IR lighting
Card reader
Connection type
Protocols
Backlight voltage 3V
Load type
Dimmer load type
Supported sensors
Input voltage 0-250V
Current type AC/DC
Adjustment type
Max load
Min load
Max load per channel 2A
Max load per group
Max load per device
Control parameters
Angle of vision IR °
Angle of motion °
Temperature measuring range °C
Humidity measuring range
Dimmer type
Dimming type
Voltage that may be applied to the input channels 0-250V
Max output switching voltage
Max output switching current
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 35 mA
Max current(13V)
Max detection distance
Max IR distance
Max BT distance
Max current
Relay
Data transfer speed
Permissible section of power supply cable to connect in socket:
single-conductor cable
multiple-conductor cable
tipped multiple-conductor cable

0.5 … 4mm2
0.5 … 4mm2
0.5 … 2.5mm2
Sensors VCC output
Sensors max VCC current
R1-R2 inputs max current
Push-button/reed switches line recommended length
Temperature sensor line max length 10m
Sensor cable length
Sensors line max length
Bus type CAN (4-wire)
Compatible with
Output voltage
Output current
Equipment installation type Free
Mounting
Max cabel lenght
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 45x42x14 mm
Weight 25 g
* -
** -
*** -
1 -
2 -
3 -


Module installation and connection procedure

  1. Connect the outputs.
  2. Connect the inputs.
  3. Connect the CAN connector.
  4. Configure the module using LT setup.
  5. Apply power to the load.
  6. Check all equipment for proper operation.

Module shut-off and deinstallation procedure

  1. Disconnect the power from the load.
  2. Disconnect the CAN connector.
  3. Disconnect the inputs.
  4. Disconnect the outputs.

HW settings

Name Type, range SUBID Default Description
runtime integer 0-100 1-2 15 runtime is the open/close time in seconds, is used for jalousie, gate, valve(2 pole); Example: runtime=15
hold integer 0-10000 1-2 500 hold is the bridging time in miliseconds, is used for gate and jalousie (by default hold is the same as runtime), lock; Example: hold=3500
def string 'ON' 1-2 'OFF' Def is the element status is set after restart, is used for lamp, heating, valve(1 pole); Example: def='ON'
offset float(+/- 0…39) 30 '0' sensor values offset;

For example, offset is -3.8 :

1hw="offset='-3.8'"
stop Char 'R' 1 (for 2-pole gate and blinds) If it is declared then by Stop command during the motion, the same impulse appears as it was at the beginning of the motion. Pole, an which the stop-impules is formed, is defined by the parameter Stop value. If it is 'r' or 'R' then stop-impulse is produced on the opposite to the start-impulse pole. If any other value is delcared (e.g., 'd' ) then the stop-impulse is on the same pole. If a Runtime passed after the beginning of the motion then the stop-impulse is not formed. Example: stop='r'
out char[2] 98 'LL' Each char is responsible for the type of a particular channel
  • 'L'-Lamp,
  • 'M'-Lamp Inverse,
  • 'J'-Heating NO,
  • 'H'-Heating NC,
  • 'B'-Jalousie (2 pole),
  • 'C'-Jalousie Inverse (2 pole),
  • 'P'-Blinds,
  • 'O'-Blinds Inverse,
  • 'G'-Gate (2 pole),
  • 'D'-Gate (2 pole) Inverse,
  • 'X'-Gate (1 pole /short press),
  • 'Z'-Gate (1 pole) Inverse,
  • 'V'-Valve (2 pole),
  • 'W'-Valve (2 pole) Inverse,
  • 'R'-Valve (1 pole),
  • 'S'-Valve (1 pole) Inverse,
  • 'K'-Lock (short press),
  • 'N'-Lock (short press) Inverse,

WARNING! The module will stop working and will not be covered under warranty if used with high current or high inrush current with low-current settings

  • 'Y'-Low-current lamp,
  • 'T'-Low-current lamp Inverse,
  • 'F'-Low-current blinds,
  • 'A'-Low-current blinds Inverse,
  • 'Q'-Low-current jalousie,
  • 'E'-Low-current jalousie Inverse,
  • 'I'-Low-current gate,
  • 'U'-Low-current gate Inverse,
  • '-'-none

Example:

1hw="out='LM'"
in char[6] 98 'BBBBKK' Each char is responsible for the type of a particular channel
  • 'B'-Button,
  • 'C'-Inverted button,
  • 'D'-Backlit button,
  • 'E'-Inverted backlit button,
  • 'S'-Switch,
  • 'K'-Contact,
  • 'H'-Inverted contact,
  • '-'-none

and you can also connect one temperature sensor

1in='T-----'

Example:

1hw="in='BBBKKK'"

Input HW configuration

chanel 1 2 3 4 5 6
Button
nButton
Switch
Contact
nContact
none
+ + + + + +
LedButton
nLedButton
+ + + + +
Temperature Sensor +
1<item addr="501:1" cfgid="171" name="Valve" type="valve" uniq_id="4169"/>
2<item addr="501:14" cfgid="171" name="Door" type="door-sensor" uniq_id="4168"/>
3<item addr="501:15" cfgid="171" name="Switch" type="switch" uniq_id="4128"/>
4<item addr="501:30" cfgid="171" name="Temperature" hw="offset='-10'" type="temperature-sensor" uniq_id="4171"/>
5<item addr="501:97" cfgid="171" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3998"/>
6<item addr="501:98" cfgid="171" hw="out='V-' in='T--KD-'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="3999"/>