Difference between revisions of "WW-WL.B"
| (2 intermediate revisions by one other user not shown) | |||
| Line 2: | Line 2: | ||
<translate> | <translate> | ||
<!--T:1--> | <!--T:1--> | ||
| − | |||
{{Infobox module | {{Infobox module | ||
| − | | name = | + | | name = WW-WL.B |
| image = WW-WLB.png | | image = WW-WLB.png | ||
| voltage = 9-12 V DC | | voltage = 9-12 V DC | ||
| Line 24: | Line 23: | ||
<!--T:6--> | <!--T:6--> | ||
| − | [[File: | + | [[File:WWWLB_EXA.png|400px]] |
| − | |||
==Module parameters== <!--T:9--> | ==Module parameters== <!--T:9--> | ||
| Line 107: | Line 105: | ||
* Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly. | * Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly. | ||
** Green and blue cannot be used at the same time. Green has priority. | ** Green and blue cannot be used at the same time. Green has priority. | ||
| + | |||
</translate> | </translate> | ||
Latest revision as of 15:36, 17 July 2025
| WW-WL.B | |||||||
|---|---|---|---|---|---|---|---|
![]() | |||||||
| |||||||
WALL LEAKAGE SENSOR
The sensor is placed on the wall. Used together with DW-WL02 or BW-LSA modules.
Features
- Sensor presence detection
- Adjusting the sensor sensitivity
- Connections of several sensors to one bus
Example of connection
Module parameters
| Parameter name | Value |
|---|---|
| Power supply | 9-12 V DC |
| Max current(24V) | 20 mA |
| Compatible with | Metaforsa devices DW-WL02/HTxx BW-LSA |
| Equipment installation type | Free |
| Case material | ABS |
| Protection | IP64 |
| Temperature range | -10 … +50 °C |
| Size | 57x47x22 mm |
| Weight | 35g |
HW settings
| Name | Type, range | SUBID | Default | Description |
|---|---|---|---|---|
| c0 | int[4] | sensors subId | 0;0;255;15 | Normal state color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c0='150;150;255;0'
|
| c1 | int[4] | sensors subId | 0;0;255;15 | On-start color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c1='150;150;255;0'
|
| c2 | int[4] | sensors subId | 255;100;0;15 | 'Leak was previously reported' color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c2='150;150;255;0'
|
| c3 | int[4] | sensors subId | 255;0;0;15 | On-leak color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c3='150;150;255;0'
|
| sens | int | sensors subId | 128 | Sensor sensitivity
Example: 1sens='180'
|
| test | int(0,1) | sensors subId | 1 | 0 - Disable the test signal to detect the presence of the sensor |
- Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.
- Green and blue cannot be used at the same time. Green has priority.