Difference between revisions of "DW-IO"

From Larnitech wiki page
Jump to navigation Jump to search
m (Add HW table)
 
(28 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
<translate>
 
<translate>
 
<!--T:1-->
 
<!--T:1-->
{{RevisionChanger | hasA = 0 | hasB = 0 | hasC = 1}}
 
 
{{Infobox module
 
{{Infobox module
 
| name      = DW-IO.C
 
| name      = DW-IO.C
| image      = DW-IOC.png
+
| image      = DW-IO.png
 
| outCount  =  
 
| outCount  =  
 
| dimmOut    =  
 
| dimmOut    =  
Line 11: Line 10:
 
| peakdl    =  
 
| peakdl    =  
 
| dt        =  
 
| dt        =  
| inCount    = 16
 
| inB        = 15
 
| inLB      = 8
 
 
| inDry      =  
 
| inDry      =  
 
| voltage    = 11.5...27.5 V DC
 
| voltage    = 11.5...27.5 V DC
Line 19: Line 15:
 
}}
 
}}
  
==16-CHANNEL ADAPTER FOR BUTTONS== <!--T:2-->
+
==14-CHANNEL INPUT/OUTPUT ADAPTER== <!--T:2-->
  
 
<!--T:3-->
 
<!--T:3-->
This module can support up to 15 buttons/reed switches or 8 LED buttons.
+
This module can support up to 14 buttons/reed switches/LED buttons/leak sensors/motion sensors/temperature sensors/led strips/rgb strips/WS2812B  strips.
  
 
==Features== <!--T:4-->
 
==Features== <!--T:4-->
*Up to 15 buttons/reed switches
+
*14 universal input/output channels support:
*Up to 8 LED buttons
+
**Buttons
*Supports single/double/triple/long click.<br>Up to 4 different actions for each button
+
**Reed switches
*Line noise protection
+
**LED buttons
 +
**Leak sensors
 +
**Motion sensors
 +
**Temperature sensors
 +
**Led strips
 +
**3-4-5 channel rgb strips
 +
**WS2812B strips.
  
 
<!--T:5-->
 
<!--T:5-->
Line 61: Line 63:
 
<!--T:11-->
 
<!--T:11-->
 
[[File:IOC_CONN.png|300px]]
 
[[File:IOC_CONN.png|300px]]
 +
 +
==Example of temperature sensors connection== <!--T:18-->
 +
 +
<!--T:19-->
 +
[[File:IOC_CONN_T.png|200px|Contactor]]
 +
 +
==Example of motion/leakage sensors connection== <!--T:18-->
 +
 +
<!--T:19-->
 +
[[File:IOC_CONN_LM.png|300px|Contactor]]
  
 
==Led button scheme== <!--T:12-->
 
==Led button scheme== <!--T:12-->
Line 67: Line 79:
 
[[File:SW16C LED.jpg|200px]]
 
[[File:SW16C LED.jpg|200px]]
  
==Connection of buttons/LED buttons== <!--T:14-->
+
==RGB connection scheme== <!--T:13-->
 +
 
 +
<!--T:14-->
 +
<div class="caution">CAUTION! Output channels should only be connected using amplifier which uses 5V PWM signal from DW-IO output as input</div>
 +
[[File:IOC_RGB_EX.png|500px]]
 +
 
 +
==WS2812B connection scheme== <!--T:13-->
  
<!--T:15-->
+
<!--T:14-->
[[File:SW16C EXA.png|500px]]
+
[[File:IOC_CONN_WS.png|300px]]
  
 
==Module parameters== <!--T:16-->
 
==Module parameters== <!--T:16-->
Line 76: Line 94:
 
<!--T:17-->
 
<!--T:17-->
 
{{ Mp
 
{{ Mp
| inqty           = 16
+
| ioqty           = 14
| buttons        = 15
+
| maxperch        = 5mA*
| ledbuttons      = 8
 
 
| blvoltage      = 3V
 
| blvoltage      = 3V
 
| power          = 11.5 … 27.5 V DC from CAN
 
| power          = 11.5 … 27.5 V DC from CAN
| maxcur24v      = 45 mA
+
| maxcur24v      = 30 mA
 
| buttonreclen    = 30m
 
| buttonreclen    = 30m
 
| bustype        = CAN (4-wire)
 
| bustype        = CAN (4-wire)
Line 90: Line 107:
 
| size            = 2U, 36x102x58 mm
 
| size            = 2U, 36x102x58 mm
 
| weight          = 75g
 
| weight          = 75g
 +
| star1          =Output channels should only be connected using amplifier which uses 5V PWM signal from DW-IO output as input
 
}}
 
}}
  
Line 98: Line 116:
 
{{indicationfw
 
{{indicationfw
 
|err1 = 1
 
|err1 = 1
|err5 = 1
 
 
|canact = 1
 
|canact = 1
 
|canacttxt = Key pressed
 
|canacttxt = Key pressed
Line 125: Line 142:
 
*'2' - linear-dimmer
 
*'2' - linear-dimmer
 
*'3'..'6' - RGB-3..6 channels
 
*'3'..'6' - RGB-3..6 channels
*'z' - WS-string
+
*'z' - WS2812B -string
  
 
*'e' - led-button inverse
 
*'e' - led-button inverse
Line 132: Line 149:
 
*'b' - button
 
*'b' - button
 
*'s' - switch
 
*'s' - switch
*'k' - contact inverse
+
*'k' - contact
*'h' - contact
+
*'h' - contact inverse
 
*'l' - leak
 
*'l' - leak
 
*'n' - Neptun
 
*'n' - Neptun
 
*'v' - motion inverse
 
*'v' - motion inverse
*'v' - motion
+
*'m' - motion
 
*'r' - thermo-resistor
 
*'r' - thermo-resistor
 
*'t' - DALLAS
 
*'t' - DALLAS
Line 143: Line 160:
 
*'-' - none
 
*'-' - none
 
Example: io='4---1-T-3-----'
 
Example: io='4---1-T-3-----'
 +
|-
 +
|hw||string||98||-||hw="...", where
 +
*pwm_invert – PWM inverting [1, 0];
 +
*lbn_bright – brightness of led buttons, range (0 - 255);
 +
*f – by default PWM frequency is 1000, range (1 - 5000).
 +
Example:
 +
<syntaxhighlight lang="xml" line>
 +
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
 +
</syntaxhighlight>
 
|}
 
|}
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
<item addr="441:11" cfgid="55" name="Switch" type="switch" uniq_id="4628"/>
+
      <item addr="317:1" auto-period="600" cfgid="195" channels="4" name="RGB" type="rgb-lamp"/>
<item addr="441:12" cfgid="55" name="Switch" type="switch" uniq_id="4629"/>
+
<item addr="317:5" auto-period="600" cfgid="195" hw="length=26 runtime=5" name="RGB" type="rgb-lamp"/>
<item addr="441:13" cfgid="55" name="Switch" type="switch" uniq_id="4630"/>
+
<item addr="317:6" cfgid="195" name="Switch" type="switch"/>
<item addr="441:14" cfgid="55" name="Switch" type="switch" uniq_id="4631"/>
+
<item addr="317:7" cfgid="195" name="Switch" type="switch"/>
<item addr="441:15" cfgid="55" name="Switch" type="switch" uniq_id="4632"/>
+
<item addr="317:12" cfgid="195" name="Temperature" type="temperature-sensor"/>
<item addr="441:16" cfgid="55" name="Switch" type="switch" uniq_id="4633"/>
+
<item addr="317:97" cfgid="195" name="Temperature" system="yes" type="temperature-sensor"/>
<item addr="441:17" cfgid="55" name="Switch" type="switch" uniq_id="4634"/>
+
<item addr="317:98" cfgid="195" hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" logic-ver="19" name="Temperature" sn="1529500271" system="yes" type="temperature-sensor"/>
<item addr="441:18" cfgid="55" name="Door" type="door-sensor" uniq_id="4637"/>
+
<item addr="317:100" cfgid="195" name="RS232" type="com-port"/>
<item addr="441:19" cfgid="55" name="Switch" type="switch" uniq_id="4638"/>
 
<item addr="441:20" cfgid="55" name="Switch" type="switch" uniq_id="4639"/>
 
<item addr="441:25" cfgid="55" name="Switch" type="switch" uniq_id="4640"/>
 
<item addr="441:98" cfgid="55" hw="io='4---1-T-3-----'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="4636"/>
 
 
</syntaxhighlight>
 
</syntaxhighlight>
 
</translate>
 
</translate>

Latest revision as of 12:50, 5 April 2024


DW-IO.C
DW-IO.png
Other
Supply voltage11.5...27.5 V DC
Dimentions2U, 36x102x58 mm


14-CHANNEL INPUT/OUTPUT ADAPTER

This module can support up to 14 buttons/reed switches/LED buttons/leak sensors/motion sensors/temperature sensors/led strips/rgb strips/WS2812B strips.

Features

  • 14 universal input/output channels support:
    • Buttons
    • Reed switches
    • LED buttons
    • Leak sensors
    • Motion sensors
    • Temperature sensors
    • Led strips
    • 3-4-5 channel rgb strips
    • WS2812B strips.

CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment. To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:

  • all connectivity work must be carried out with the power turned OFF;
  • use appropriate tools and personal protection against electric shock;
  • do not use damaged cables, wires and connectors;
  • avoid folding the cables and wires;
  • do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
  • do not use the power socket with poor contacts to connect;
  • do not exceed the load limit parameters specified in the manual;
  • the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.

When the power is on, NEVER:

  • connect/disconnect the connectors;
  • open modules and sensors.

Overview

IOC VIEW.png

Module dimensions

IOC DIM.png

Connector

IOC CONN.png

Example of temperature sensors connection

Contactor

Example of motion/leakage sensors connection

Contactor

Led button scheme

SW16C LED.jpg

RGB connection scheme

CAUTION! Output channels should only be connected using amplifier which uses 5V PWM signal from DW-IO output as input

IOC RGB EX.png

WS2812B connection scheme

IOC CONN WS.png

Module parameters

Parameter name Value
Input channels qty
Input/output channels qty 14
0-10 input port quantity
Buttons
LED Buttons
Number of sensor inputs
Number of dry contact inputs
RS485 ports qty
RS232 ports qty
UART ports qty
M-BUS port quantity
Pulse inputs quantity
DALI ports qty
DALI-line voltage supply
Peak current of DALI-line power supply
Peak current in DALI-line
Maximum DALI devices quantity
Dimming channels qty
Output channels qty
0-10 output port quantity
Analog output channels qty
Output
Digital line maximum length
Discrete input channels qty
Digital input channels qty
Speakers
Max power output audio channel
Camera
IR lighting
Card reader
Connection type
Protocols
Backlight voltage 3V
Load type
Dimmer load type
Supported sensors
Input voltage
Current type
Adjustment type
Max load
Min load
Max load per channel 5mA*
Max load per group
Max load per device
Control parameters
Angle of vision IR °
Angle of motion °
Temperature measuring range °C
Humidity measuring range
Dimmer type
Dimming type
Voltage that may be applied to the input channels
Max output switching voltage
Max output switching current
Power supply 11.5 … 27.5 V DC from CAN
Max current(24V) 30 mA
Max current(13V)
Max detection distance
Max IR distance
Max BT distance
Max current
Relay
Data transfer speed
Permissible section of power supply cable to connect in socket:
Sensors VCC output
Sensors max VCC current
R1-R2 inputs max current
Push-button/reed switches line recommended length 30m
Temperature sensor line max length
Sensor cable length
Sensors line max length
Bus type CAN (4-wire)
Compatible with
Output voltage
Output current
Equipment installation type DIN rail (EN 60715)
Mounting
Max cabel lenght
Case material ABS
Protection IP40
Temperature range -10 … +50 °C
Size 2U, 36x102x58 mm
Weight 75g
* - Output channels should only be connected using amplifier which uses 5V PWM signal from DW-IO output as input
** -
*** -
1 -
2 -
3 -


Indication of module operation

Bootloader

Indicator Status Description
Top.png
Yl.png Device in bootloader
Bot.png
B.pngB.png Downloading firmware
R.pngR.png Flashing firmware

Firmware

Indicator Status Description
Top.png
G.pngG.pngG.pngDots.png Network configuration
B.pngB.pngB.pngDots.png Identification
Gl.png Operational mode
Yl.png Operational mode
Bot.png

Error
R.png Lost connection to server
R.pngR.png Overheat
R.pngR.pngR.png Overload
R.pngR.pngR.pngR.png No AC power
R.pngR.pngR.pngR.pngR.png RTC error
Bot.png

Activity
Y.png Key pressed
Bg.png OW activity
M.png RS-485 activity
B.png Ethernet activity


Module installation and connection procedure

  1. Install the module in the switchboard on the DIN rail and fix it with the special latch on the module base.
  2. Connect the X1 connector.
  3. Connect the CAN connector.
  4. Configure the module using LT setup.
  5. Check all equipment for proper operation.

Module shut-off and deinstallation procedure

  1. Disconnect the CAN connector.
  2. Disconnect the X1 connector.
  3. Remove the module from the DIN rail, releasing the latch at the bottom of the module base.

HW settings

Name Type, range SUBID Default Description
io char[14] 98 '4---1-T-3-----' Each char is responsible for the type of a particular channel
  • '0' - led-dimmer
  • '1' - halogen-dimmer
  • '2' - linear-dimmer
  • '3'..'6' - RGB-3..6 channels
  • 'z' - WS2812B -string
  • 'e' - led-button inverse
  • 'd' - led-button
  • 'c' - button inverse
  • 'b' - button
  • 's' - switch
  • 'k' - contact
  • 'h' - contact inverse
  • 'l' - leak
  • 'n' - Neptun
  • 'v' - motion inverse
  • 'm' - motion
  • 'r' - thermo-resistor
  • 't' - DALLAS
  • '-' - none

Example: io='4---1-T-3-----'

hw string 98 - hw="...", where
  • pwm_invert – PWM inverting [1, 0];
  • lbn_bright – brightness of led buttons, range (0 - 255);
  • f – by default PWM frequency is 1000, range (1 - 5000).

Example:

1hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
1      <item addr="317:1" auto-period="600" cfgid="195" channels="4" name="RGB" type="rgb-lamp"/>
2		<item addr="317:5" auto-period="600" cfgid="195" hw="length=26 runtime=5" name="RGB" type="rgb-lamp"/>
3		<item addr="317:6" cfgid="195" name="Switch" type="switch"/>
4		<item addr="317:7" cfgid="195" name="Switch" type="switch"/>
5		<item addr="317:12" cfgid="195" name="Temperature" type="temperature-sensor"/>
6		<item addr="317:97" cfgid="195" name="Temperature" system="yes" type="temperature-sensor"/>
7		<item addr="317:98" cfgid="195" hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" logic-ver="19" name="Temperature" sn="1529500271" system="yes" type="temperature-sensor"/>
8		<item addr="317:100" cfgid="195" name="RS232" type="com-port"/>