Difference between revisions of "Ventilation"
Jump to navigation
Jump to search
(Created page with "Ventilation ===Example of description in XML=== <syntaxhighlight lang="xml" line> <item addr="345:123" length="6" name="Ventilation" sub-type="ventilation" type="virtual"/>...") |
(Marked this version for translation) |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | <languages/> | ||
+ | <translate> | ||
Ventilation | Ventilation | ||
− | ===Example of description in XML=== | + | ===Example of description in XML=== <!--T:1--> |
+ | <!--T:2--> | ||
<syntaxhighlight lang="xml" line> | <syntaxhighlight lang="xml" line> | ||
<item addr="345:123" length="6" name="Ventilation" sub-type="ventilation" type="virtual"/> | <item addr="345:123" length="6" name="Ventilation" sub-type="ventilation" type="virtual"/> | ||
Line 8: | Line 11: | ||
</syntaxhighlight> | </syntaxhighlight> | ||
− | ===Additional parameters=== | + | ===Additional parameters=== <!--T:3--> |
+ | <!--T:4--> | ||
{|class="wikitable" | {|class="wikitable" | ||
|- | |- | ||
Line 20: | Line 24: | ||
<nowiki>*</nowiki> – required fields | <nowiki>*</nowiki> – required fields | ||
− | ===Device status (6 bytes)=== | + | ===Device status (6 bytes)=== <!--T:5--> |
− | {|class=" | + | <!--T:6--> |
+ | {|class="wikitable" | ||
|- | |- | ||
!Byte number!!Description | !Byte number!!Description | ||
Line 33: | Line 38: | ||
|} | |} | ||
− | ===Status setting=== | + | ===Status setting=== <!--T:7--> |
+ | <!--T:8--> | ||
from the 1st to the 6th correspondingly | from the 1st to the 6th correspondingly | ||
+ | </translate> |
Latest revision as of 14:59, 24 January 2022
Ventilation
Example of description in XML
1<item addr="345:123" length="6" name="Ventilation" sub-type="ventilation" type="virtual"/>
2// Ventilation virtual device description
3<import-script id="345" VENT="80" RS485="345:12" path="vent.txt"/> // Ventilation control script description
Additional parameters
Name | type and variety | description | default value |
---|---|---|---|
sub-type* | string, ventilation | subtype | ventilation |
funs | bit mask | Mask of airflow mode | 0xFF |
* – required fields
Device status (6 bytes)
Byte number | Description |
---|---|
0 | 0 bit – 0 is off, 1 is on |
1 | 0-3d bit – temperature (+16 is to be added to the value) |
4 | 0-3d bit – airflow capacity |
Status setting
from the 1st to the 6th correspondingly