Difference between revisions of "FW-WL.B"
Jump to navigation
Jump to search
m |
|||
(One intermediate revision by one other user not shown) | |||
Line 1: | Line 1: | ||
<languages/> | <languages/> | ||
<translate> | <translate> | ||
+ | <!--T:1--> | ||
{{RevisionChanger | hasA = 1 | hasB = 1}} | {{RevisionChanger | hasA = 1 | hasB = 1}} | ||
{{Infobox module | {{Infobox module | ||
| name = FW-WL.B | | name = FW-WL.B | ||
− | | image = FW-WLB. | + | | image = FW-WLB.png |
| voltage = 9-12 V DC | | voltage = 9-12 V DC | ||
| dim = 57x47x22 mm | | dim = 57x47x22 mm | ||
}} | }} | ||
− | ==ON-THE-FLOOR LEAKAGE SENSOR== | + | ==ON-THE-FLOOR LEAKAGE SENSOR== <!--T:2--> |
+ | <!--T:3--> | ||
The sensor is placed on the floor surface. It has an alarm light, which | The sensor is placed on the floor surface. It has an alarm light, which | ||
changes from green to red if the sensor detects water on the floor. | changes from green to red if the sensor detects water on the floor. | ||
Used together with DW-WL02 or BW-LSA modules. | Used together with DW-WL02 or BW-LSA modules. | ||
− | ==Features== | + | ==Features== <!--T:4--> |
*Sensor presence detection | *Sensor presence detection | ||
*Customizing the indication colors | *Customizing the indication colors | ||
Line 21: | Line 23: | ||
*Connections of several sensors to one bus | *Connections of several sensors to one bus | ||
− | ==Example of connection== | + | ==Example of connection== <!--T:5--> |
+ | <!--T:6--> | ||
[[File:FWWLB EXA.jpg|400px]] | [[File:FWWLB EXA.jpg|400px]] | ||
− | ==Connectors== | + | ==Connectors== <!--T:7--> |
+ | <!--T:8--> | ||
[[File:FWWLB CON.png|400px]] | [[File:FWWLB CON.png|400px]] | ||
− | ==Module parameters== | + | ==Module parameters== <!--T:9--> |
+ | <!--T:10--> | ||
{{ Mp | {{ Mp | ||
| power = 9-12 V DC | | power = 9-12 V DC | ||
Line 43: | Line 48: | ||
}} | }} | ||
− | ==HW settings== | + | ==HW settings== <!--T:11--> |
{|class="wikitable" | {|class="wikitable" | ||
|- | |- | ||
Line 105: | Line 110: | ||
|} | |} | ||
+ | <!--T:12--> | ||
* Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly. | * Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly. | ||
** Green and blue cannot be used at the same time. Green has priority. | ** Green and blue cannot be used at the same time. Green has priority. | ||
</translate> | </translate> |
Latest revision as of 06:20, 11 August 2022
FW-WL.B | |||||||
---|---|---|---|---|---|---|---|
|
ON-THE-FLOOR LEAKAGE SENSOR
The sensor is placed on the floor surface. It has an alarm light, which changes from green to red if the sensor detects water on the floor. Used together with DW-WL02 or BW-LSA modules.
Features
- Sensor presence detection
- Customizing the indication colors
- Adjusting the sensor sensitivity
- Connections of several sensors to one bus
Example of connection
Connectors
Module parameters
Parameter name | Value |
---|---|
Power supply | 9-12 V DC |
Max current(24V) | 20 mA |
Compatible with | Metaforsa devices DW-WL02/HTxx BW-LSA |
Equipment installation type | Free |
Case material | ABS |
Protection | IP64 |
Temperature range | -10 … +50 °C |
Size | 57x47x22 mm |
Weight | 35g |
HW settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
c0 | int[4] | sensors subId | 0;0;255;15 | Normal state color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c0='150;150;255;0'
|
c1 | int[4] | sensors subId | 0;0;255;15 | On-start color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c1='150;150;255;0'
|
c2 | int[4] | sensors subId | 255;100;0;15 | 'Leak was previously reported' color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c2='150;150;255;0'
|
c3 | int[4] | sensors subId | 255;0;0;15 | On-leak color in format 'red;green;blue;blink'
red, green, blue – 0..255; blink:
Example: 1c3='150;150;255;0'
|
sens | int | sensors subId | 128 | Sensor sensitivity
Example: 1sens='180'
|
test | int(0,1) | sensors subId | 1 | 0 - Disable the test signal to detect the presence of the sensor |
- Removing HW does not return the above parameters to their default values.To return to their default values, they must be set explicitly.
- Green and blue cannot be used at the same time. Green has priority.