Control parametersTemperature
Temperature measuring range-20 … +60°C
Other
Supply voltage5 V DC
Dimentions5x4x8 mm


ДАТЧИК ТЕМПЕРАТУРЫ

Open-frame temperature sensor for DW-HCxx module.

Pin assignments

FWTS PIN.jpg

Example of connection

FWTS EXA.jpg

Module parameters

Parameter name Value
Input channels qty
Input/output channels qty
0-10 input port quantity
Buttons
LED Buttons
Number of sensor inputs
Number of dry contact inputs
RS485 ports qty
RS232 ports qty
UART ports qty
M-BUS port quantity
Pulse inputs quantity
DALI ports qty
DALI-line voltage supply
Peak current of DALI-line power supply
Peak current in DALI-line
Maximum DALI devices quantity
Dimming channels qty
Output channels qty
0-10 output port quantity
Analog output channels qty
Output
Digital line maximum length
Discrete input channels qty
Digital input channels qty
Speakers
Max power output audio channel
Camera
IR lighting
Card reader
Connection type
Protocols
Backlight voltage
Load type
Dimmer load type
Supported sensors
Input voltage
Current type
Adjustment type
Max load
Min load
Max load per channel
Max load per group
Max load per device
Control parameters Temperature
Angle of vision IR °
Angle of motion °
Temperature measuring range -20 … +60°C
Humidity measuring range
Dimmer type
Dimming type
Voltage that may be applied to the input channels
Max output switching voltage
Max output switching current
Power supply 5 V DC
Max current(24V)
Max current(13V)
Max detection distance
Max IR distance
Max BT distance
Max current 5 mA
Relay
Data transfer speed
Permissible section of power supply cable to connect in socket:
Sensors VCC output
Sensors max VCC current
R1-R2 inputs max current
Push-button/reed switches line recommended length
Temperature sensor line max length
Sensor cable length
Sensors line max length 30 m*
Bus type One Wire
Compatible with
Output voltage
Output current
Equipment installation type Free
Mounting
Max cabel lenght
Case material ABS
Protection IP40
Temperature range -20 … +60 °C
Size 5x4x8 mm
Weight 15g
* - +5V and COM should be connected in one twisted pair, and DATA at free one
** -
*** -
1 -
2 -
3 -


HW settings

Name Type, range SUBID Default Description
offset float (+/- 0…39) SubID of sensor 0 sensor values offset (for temperature sensors) Example:
1hw="offset='-3'"