Difference between revisions of "FW-TS"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
| cp = Temperature | | cp = Temperature | ||
| temperature= -20 … +60°C | | temperature= -20 … +60°C | ||
− | | voltage = | + | | voltage = 5 V DC |
| dim = 5x4x8 mm | | dim = 5x4x8 mm | ||
}} | }} |
Revision as of 14:00, 17 August 2021
FW-TS | |||||||
---|---|---|---|---|---|---|---|
| |||||||
|
TEMPERATURE SENSOR
Open-frame temperature sensor for DW-HCxx module.
Pin assignments
Example of connection
Module parameters
Parameter name | Value |
---|---|
Control parameters | Temperature |
Temperature measuring range | -20 … +60°C |
Power supply | 5 V DC |
Max current | 5 mA |
Sensors line max length | 30 m* |
Bus type | One Wire |
Equipment installation type | Free |
Case material | ABS |
Protection | IP40 |
Temperature range | -20 … +60 °C |
Size | 5x4x8 mm |
Weight | 15g |
* - +5V and COM should be connected in one twisted pair, and DATA at free one
HW settings
Name | Type, range | SUBID | Default | Description |
---|---|---|---|---|
offset | float (+/- 0…39) | SubID of sensor | 0 | sensor values offset (for temperature sensors) Example:
1hw="offset='-3'"
|