Difference between revisions of "Valve"
Jump to navigation
Jump to search
(Created page with "water and gas supplying valve type executor ===Example of description in XML=== <syntaxhighlight lang="xml" line> <item type="valve" addr="314:7" name="Valve" leak-sensors="3...") |
|||
Line 9: | Line 9: | ||
===Additional parameters=== | ===Additional parameters=== | ||
− | {class="wikitable" | + | {|class="wikitable" |
|- | |- | ||
!Name!!type and variety!!description!!default value | !Name!!type and variety!!description!!default value | ||
Line 15: | Line 15: | ||
|leak-sensors||list||list of leakage sensors connected with this valve | |leak-sensors||list||list of leakage sensors connected with this valve | ||
|} | |} | ||
+ | |||
===Device status (1 byte)=== | ===Device status (1 byte)=== | ||
{class="wikitable" | {class="wikitable" |
Revision as of 13:01, 19 August 2021
water and gas supplying valve type executor
Example of description in XML
1<item type="valve" addr="314:7" name="Valve" leak-sensors="314:3;304:10;302:10">
2 <linked addr="314:1"/> // valve control button (optionally)
3</item>
Additional parameters
Name | type and variety | description | default value |
---|---|---|---|
leak-sensors | list | list of leakage sensors connected with this valve |
Device status (1 byte)
{class="wikitable"
|-
!Byte number!!description
|-
|0||Device status.
0 – valve is off (water supply)
1 – valve is on (water supply is stopped)
|}
Possible variants of setting the status
{class="wikitable"
|-
!byte!!description
|-
|0||0 – to turn off the valve (water supply)
1 – to turn on the valve (to stop water supply)
0xFF – Change the status for the opposite one
|}