Difference between revisions of "Translations:Metaforsa 3/3.plus/94/en"

From Larnitech wiki page
Jump to navigation Jump to search
(Importing a new version from external source)
 
(Importing a new version from external source)
 
Line 12: Line 12:
 
*'r' - thermo-resistor
 
*'r' - thermo-resistor
 
*'t' - DALLAS
 
*'t' - DALLAS
 +
*'-' - none
 +
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
 +
|-
 +
|hw||string||98||-||hw="...", where
 +
*pwm_invert – PWM inverting [1, 0];
 +
*lbn_bright – brightness of led buttons, range (0 - 255);
 +
*f – by default PWM frequency is 1000, range (1 - 5000).
 +
Example:
 +
<syntaxhighlight lang="xml" line>
 +
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
 +
</syntaxhighlight>
 +
|-
 +
|colspan="3"|'''Only for Metaforsa 3.plus'''
 +
|-
 +
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
 +
*SPEED – baud rate [1200..115200];
 +
*B – data length [7,8];
 +
*P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
 +
*S – stop bit length [1, 1.5 or 2].
 +
Example:
 +
<syntaxhighlight lang="xml" line>
 +
hw="cfg='9600/8N1'"
 +
</syntaxhighlight>
 +
|-
 +
|[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following
 +
protocols are supported:
 +
*'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
 +
*'dmx', DMX protocol;
 +
*'CO2' for connecting Larnitech CO2 sensors;
 +
*'salda' for connecting Salda ventilation.
 +
Example:
 +
<syntaxhighlight lang="xml" line>
 +
hw="cfg='9600/8N1' modbus"
 +
</syntaxhighlight>
 +
|-
 +
|echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module
 +
echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
 +
*'off'
 +
*'on'
 +
Example:
 +
<syntaxhighlight lang="xml" line>
 +
hw="cfg='9600/8N1' echo='off'"
 +
</syntaxhighlight>
 +
|}

Latest revision as of 12:53, 5 April 2024

Information about message (contribute)
This message has no documentation. If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Metaforsa 3/3.plus)
*'e' - led-button inverse
*'d' - led-button
*'c' - button inverse
*'b' - button
*'s' - switch
*'k' - contact inverse
*'h' - contact
*'l' - leak
*'n' - Neptun
*'v' - motion inverse
*'m' - motion
*'r' - thermo-resistor
*'t' - DALLAS
*'-' - none
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", where
*pwm_invert – PWM inverting [1, 0];
*lbn_bright – brightness of led buttons, range (0 - 255);
*f – by default PWM frequency is 1000, range (1 - 5000).
Example:
<syntaxhighlight lang="xml" line>
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
</syntaxhighlight>
|-
|colspan="3"|'''Only for Metaforsa 3.plus'''
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
*SPEED – baud rate [1200..115200];
*B – data length [7,8];
*P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
*S – stop bit length [1, 1.5 or 2].
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1'"
</syntaxhighlight>
|-
|[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following
protocols are supported:
*'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
*'dmx', DMX protocol;
*'CO2' for connecting Larnitech CO2 sensors;
*'salda' for connecting Salda ventilation.
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' modbus"
</syntaxhighlight>
|-
|echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module
echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
*'off'
*'on'
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' echo='off'"
</syntaxhighlight>
|}
Translation*'e' - led-button inverse
*'d' - led-button
*'c' - button inverse
*'b' - button
*'s' - switch
*'k' - contact inverse
*'h' - contact
*'l' - leak
*'n' - Neptun
*'v' - motion inverse
*'m' - motion
*'r' - thermo-resistor
*'t' - DALLAS
*'-' - none
Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK'
|-
|hw||string||98||-||hw="...", where
*pwm_invert – PWM inverting [1, 0];
*lbn_bright – brightness of led buttons, range (0 - 255);
*f – by default PWM frequency is 1000, range (1 - 5000).
Example:
<syntaxhighlight lang="xml" line>
hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"
</syntaxhighlight>
|-
|colspan="3"|'''Only for Metaforsa 3.plus'''
|-
|cfg||string||98||9600/8N1||cfg='SPEED/BPS', where
*SPEED – baud rate [1200..115200];
*B – data length [7,8];
*P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
*S – stop bit length [1, 1.5 or 2].
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1'"
</syntaxhighlight>
|-
|[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following
protocols are supported:
*'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
*'dmx', DMX protocol;
*'CO2' for connecting Larnitech CO2 sensors;
*'salda' for connecting Salda ventilation.
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' modbus"
</syntaxhighlight>
|-
|echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module
echo-reply can be turned on or off with the help of this parameter.Echo parameter value:
*'off'
*'on'
Example:
<syntaxhighlight lang="xml" line>
hw="cfg='9600/8N1' echo='off'"
</syntaxhighlight>
|}
  • 'e' - led-button inverse
  • 'd' - led-button
  • 'c' - button inverse
  • 'b' - button
  • 's' - switch
  • 'k' - contact inverse
  • 'h' - contact
  • 'l' - leak
  • 'n' - Neptun
  • 'v' - motion inverse
  • 'm' - motion
  • 'r' - thermo-resistor
  • 't' - DALLAS
  • '-' - none

Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", where

  • pwm_invert – PWM inverting [1, 0];
  • lbn_bright – brightness of led buttons, range (0 - 255);
  • f – by default PWM frequency is 1000, range (1 - 5000).

Example:

1hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"

|- |colspan="3"|Only for Metaforsa 3.plus |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where

  • SPEED – baud rate [1200..115200];
  • B – data length [7,8];
  • P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)];
  • S – stop bit length [1, 1.5 or 2].

Example:

1hw="cfg='9600/8N1'"

|- |[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following protocols are supported:

  • 'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added;
  • 'dmx', DMX protocol;
  • 'CO2' for connecting Larnitech CO2 sensors;
  • 'salda' for connecting Salda ventilation.

Example:

1hw="cfg='9600/8N1' modbus"

|- |echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module echo-reply can be turned on or off with the help of this parameter.Echo parameter value:

  • 'off'
  • 'on'

Example:

1hw="cfg='9600/8N1' echo='off'"

|}