This module is used to connect two additional CAN networks to the system. It also converts Ethernet into CAN bus and vice versa. | This module is used to connect two additional CAN networks to the system. It also converts Ethernet into CAN bus and vice versa. |
Revision as of 15:03, 2 January 2022
DE-GW.C | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||
|
ШЛЮЗ
This module is used to connect two additional CAN networks to the system. It also converts Ethernet into CAN bus and vice versa.
CAUTION! All work related to the installation, connection, setting up, service and support must be carried out by qualified personnel with sufficient skills and experience in working with electrical equipment.To avoid the risk of fire, electric shock, damage to the system and/or personal injury, the system installation and assembly must be performed in accordance with the instructions listed below:
- all connectivity work must be carried out with the power turned OFF;
- use appropriate tools and personal protection against electric shock;
- do not use damaged cables, wires and connectors;
- avoid folding the cables and wires;
- do not apply excessive force to the wires by kinking or pressing them too hard: the inner conductors of the cables and wires may get stripped or damaged;
- do not use the power socket with poor contacts to connect;
- do not exceed the load limit parameters specified in the manual;
- the supply conductors wire section is subject to the specifications for current density limit, insulation type and wire material. Light section can result in cable overheating and fire.
When the power is on, NEVER:
- connect/disconnect the connectors;
- open modules and sensors.
Module view
- Indicators
- Ethernet
- Power supply
- CAN1
- CAN2
Сonnection example
Module dimensions
Connectors
Module parameters
Parameter name | Value |
---|---|
Type of connection | CAN, Ethernet |
Input/output interfaces | Ethernet, 2xCAN |
Data speed | 10/100Mb/s |
Max CAN deviсes | 100(50 per CAN) |
CAN bus topology | BUS |
Number of CAN ports | 2 |
Power supply | 11.5 … 27.5 V DC 24V, 2.5A Recommended |
Max own current (24V) | 140mA |
Max CAN bus length | 800 m* (twisted pair 5 cat) |
Max current per CAN bus | 700mA |
Case material | ABS |
Protection | IP40 |
Equipment installation type | DIN-rail (EN 60715) |
Temperature range | -10 … +50°C |
Size | 2U, 35x95x58 mm |
Weight | 65 g |
* – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors
Indication of module operation
Bootloader
Indicator | Status | Description |
---|---|---|
Device in bootloader | ||
Waiting for bootloader command | ||
Flashing firmware |
Firmware
Indicator | Status | Description |
---|---|---|
Network configuration | ||
Identification | ||
Operational mode | ||
Error | ||
Lost connection to server | ||
RTC error | ||
Activity | ||
CAN activity | ||
Ethernet activity |