Difference between revisions of "Dimmer-lamp"

From Larnitech wiki page
Jump to navigation Jump to search
(Marked this version for translation)
 
Line 1: Line 1:
 
<languages/>
 
<languages/>
 
<translate>
 
<translate>
===Example of description in XML===
+
===Example of description in XML=== <!--T:1-->
 
<syntaxhighlight lang="xml" line>
 
<syntaxhighlight lang="xml" line>
 
<item addr="100:10" name="chandelier" type="dimer-lamp" auto-period="600" system="yes">
 
<item addr="100:10" name="chandelier" type="dimer-lamp" auto-period="600" system="yes">
Line 15: Line 15:
 
</syntaxhighlight>
 
</syntaxhighlight>
  
 +
<!--T:2-->
 
color-temp="dimmer ID:SUBID" – for adding and control dimmer brigtness bar with temperature.
 
color-temp="dimmer ID:SUBID" – for adding and control dimmer brigtness bar with temperature.
  
 +
<!--T:3-->
 
color-white="dimmer ID:SUBID" – for adding and control dimmer brigtness bar "white".
 
color-white="dimmer ID:SUBID" – for adding and control dimmer brigtness bar "white".
  
===Device status (2 bytes)===
+
===Device status (2 bytes)=== <!--T:4-->
  
 +
<!--T:5-->
 
{|class="wikitable
 
{|class="wikitable
 
|-
 
|-
Line 30: Line 33:
 
|}
 
|}
  
===Possible variants of setting the status===
+
===Possible variants of setting the status=== <!--T:6-->
 
====single-byte====
 
====single-byte====
  
 +
<!--T:7-->
 
{|class="wikitable"
 
{|class="wikitable"
 
!byte!!description
 
!byte!!description
Line 39: Line 43:
 
|}
 
|}
  
====3-bytes====
+
====3-bytes==== <!--T:8-->
  
 +
<!--T:9-->
 
{|class="wikitable"
 
{|class="wikitable"
 
!byte!!description
 
!byte!!description

Latest revision as of 11:38, 23 January 2022

Other languages:
English • ‎русский

Example of description in XML

1<item addr="100:10" name="chandelier" type="dimer-lamp" auto-period="600" system="yes">
2    <linked addr="101:1"/>  // is bound to the button with the address 101:1
3    <automation ……/>  // set the automation for this element
4</item>
1<item addr="100:10" name="chandelier" type="dimer-lamp" auto-period="600" color-temp="307:4" color-white="307:5">
2    <linked addr="101:1"/>  // is bound to the button with the address 101:1
3    <automation ……/>  // set the automation for this element
4</item>

color-temp="dimmer ID:SUBID" – for adding and control dimmer brigtness bar with temperature.

color-white="dimmer ID:SUBID" – for adding and control dimmer brigtness bar "white".

Device status (2 bytes)

Byte number description
0 Device status.

Bit 0:
0 – off
1 – on
Bit 3:
0 – automation is disactivated
1 – automation is activated
Bit 7:
0 – no alarm
1 – alarm (relating to temperature)
1 Brightness
0..250

Possible variants of setting the status

single-byte

byte description
0 Status (on/off)
0 – off
1 – on
0xFF – Change the status for the opposite one

3-bytes

byte description
0 status (on/off)
0 – off
1 – on
0xFE – do not change the status of this byte
0xFF – Change the status for the opposite one
1 Brightness
0 – off
1..250 – brightness
0xFE – do not change the status of this byte
2 Time required for changing the status, seconds