Difference between revisions of "Ventilation"
Jump to navigation
Jump to search
| Line 1: | Line 1: | ||
| + | <languages/> | ||
| + | <translate> | ||
Ventilation | Ventilation | ||
===Example of description in XML=== | ===Example of description in XML=== | ||
| Line 36: | Line 38: | ||
from the 1st to the 6th correspondingly | from the 1st to the 6th correspondingly | ||
| + | </translate> | ||
Revision as of 14:57, 24 January 2022
Ventilation
Example of description in XML
1<item addr="345:123" length="6" name="Ventilation" sub-type="ventilation" type="virtual"/>
2// Ventilation virtual device description
3<import-script id="345" VENT="80" RS485="345:12" path="vent.txt"/> // Ventilation control script description
Additional parameters
| Name | type and variety | description | default value |
|---|---|---|---|
| sub-type* | string, ventilation | subtype | ventilation |
| funs | bit mask | Mask of airflow mode | 0xFF |
* – required fields
Device status (6 bytes)
| Byte number | Description |
|---|---|
| 0 | 0 bit – 0 is off, 1 is on |
| 1 | 0-3d bit – temperature (+16 is to be added to the value) |
| 4 | 0-3d bit – airflow capacity |
Status setting
from the 1st to the 6th correspondingly