Translations:Metaforsa 3/3.plus/94/de

From Larnitech wiki page
Revision as of 14:09, 5 April 2024 by Support (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
  • e' - led-taste invers
  • 'd' - led-taste
  • 'c' - Taste invers
  • 'b' - Taster
  • 's' - Schalter
  • 'k' - Kontakt invers
  • 'h' - Kontakt
  • 'l' - Leck
  • 'n' - Neptun
  • 'v' - Bewegung invers
  • 'm' - Bewegung
  • 'r' - Thermowiderstand
  • 't' - DALLAS
  • '-' - keine

Beispiel: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", wobei

  • pwm_invert - PWM-Invertierung [1, 0];
  • lbn_bright - Helligkeit der LED-Tasten, Bereich (0 - 255);
  • f - standardmäßig ist die PWM-Frequenz 1000, Bereich (1 - 5000).

Beispiel:

1hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000"

|- |colspan="3"|Nur für Metaforsa 3.plus |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', wobei

  • SPEED - Baudrate [1200..115200];
  • B - Datenlänge [7,8];
  • P - Vorhandensein und Art des Paritätsbits [N(Keine Parität),E(Gerade Parität),O(Ungerade Parität)];
  • S - Länge des Stoppbits [1, 1,5 oder 2].

Beispiel:

1hw="cfg='9600/8N1'"

|- |[Protocol]||string||98||—||Die Protokolleinstellung wird durch Protokollparameter beschrieben. Die folgenden Protokolle werden unterstützt:

  • 'modbus', Modbus-Protokoll, am Ende der Umleitung wird die Prüfsumme CRC16 (Modbus) hinzugefügt;
  • 'dmx', DMX-Protokoll;
  • 'CO2' für den Anschluss von Larnitech CO2-Sensoren;
  • 'salda' für den Anschluss der Salda-Lüftung.

Beispiel:

1hw="cfg='9600/8N1' modbus"

|- |echo||on; off||98||'off'||Zum Einstellen und Testen können die Echo-Parameter verwendet werden. Modul echo-reply kann mit Hilfe dieses Parameters ein- oder ausgeschaltet werden.echo parameter value:

  • 'off'
  • 'ein'

Beispiel:

1hw="cfg='9600/8N1' echo='off'"

|}