h bosanski (bs) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h čeština (cs) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h dansk (da) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h Deutsch (de) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h English (en) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h español (es) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h français (fr) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h Ἀρχαία ἑλληνικὴ (grc) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h magyar (hu) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h italiano (it) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h lietuvių (lt) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h Nederlands (nl) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h polski (pl) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h português (pt) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h română (ro) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h русский (ru) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h slovenčina (sk) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h slovenščina (sl) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h српски / srpski (sr) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |
h українська (uk) | <syntaxhighlight lang="xml" line> <item addr="339:1" auto-period="600" cfgid="40" hw="def='ON'" name="Lamp" type="lamp" uniq_id="3779"> <item addr="339:2" cfgid="40" hw="def='ON'" name="Radiator" type="valve-heating" uniq_id="3780"> <automation name="Eco" temperature-level="16" uniq_id="3781"/> <automation name="Comfort" temperature-level="22" uniq_id="3782"/> <automation name="Hot" temperature-level="25" uniq_id="3783"/> </item> <item addr="339:3" cfgid="40" hw="runtime=9" name="Jalousie" sub-type="120" type="jalousie" uniq_id="32"/> <item addr="339:5" cfgid="40" hw="runtime=13" name="Gate" sub-type="120" type="gate" uniq_id="3784"/> <item addr="339:7" cfgid="40" hw="hold=4600" name="Gate" sub-type="120" type="gate" uniq_id="3785"/> <item addr="339:8" cfgid="40" hw="runtime=10" name="Valve" type="valve" uniq_id="3786"/> <item addr="339:11" cfgid="40" name="Motion" type="motion-sensor" uniq_id="17"/> <item addr="339:12" cfgid="40" name="Motion" type="motion-sensor" uniq_id="18"/> <item addr="339:13" cfgid="40" name="Motion" type="motion-sensor" uniq_id="19"/> <item addr="339:16" cfgid="40" name="Leak" type="leak-sensor" uniq_id="21"/> <item addr="339:17" cfgid="40" name="Leak" type="leak-sensor" uniq_id="41"/> <item addr="339:19" cfgid="40" name="Switch" type="switch" uniq_id="22"/> <item addr="339:20" cfgid="40" name="Switch" type="switch" uniq_id="23"/> <item addr="339:21" cfgid="40" name="Switch" type="switch" uniq_id="24"/> <item addr="339:22" cfgid="40" name="Switch" type="switch" uniq_id="25"/> <item addr="339:23" cfgid="40" name="Door" type="door-sensor" uniq_id="26"/> <item addr="339:24" cfgid="40" name="Door" type="door-sensor" uniq_id="27"/> <item addr="339:25" cfgid="40" name="Door" type="door-sensor" uniq_id="28"/> <item addr="339:26" cfgid="40" name="Door" type="door-sensor" uniq_id="29"/> <item addr="339:30" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3772"/> <item addr="339:31" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3773"/> <item addr="339:32" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3774"/> <item addr="339:33" cfgid="40" hw="offset='-10.8'" name="Temperature" type="temperature-sensor" uniq_id="3775"/> <item addr="339:34" cfgid="40" hw="offset='25.1'" name="Temperature" type="temperature-sensor" uniq_id="3776"/> <item addr="339:35" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3777"/> <item addr="339:36" cfgid="40" name="Temperature" type="temperature-sensor" uniq_id="3778"/> <item addr="339:98" cfgid="40" hw="out='LHB-G-XV--' in='MMM--LL-BBBBKKKK'" name="Temperature" system="yes" type="temperature-sensor" uniq_id="30"/> </syntaxhighlight> |