h bosanski (bs) | *'e' - LED-dugme inverzno *'d' - LED-dugme *'c' - dugme obrnuto *'b' - dugme *'s' - prekidač *'k' - kontakt inverzan *'h' - kontakt *'l' - curenje *'n' - Neptun *'v' - inverzno kretanje *'m' - pokret *'r' - termo-otpornik *'t' - DALLAS *'-' - nijedan primjer: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", gdje *pwm_invert – PWM invertiranje [1, 0]; *lbn_bright – svjetlina LED dugmadi, raspon (0 - 255); *f – po defaultu PWM frekvencija je 1000, raspon (1 - 5000). primjer: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Samo za Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', gdje *SPEED – brzina prijenosa [1200..115200]; *B – dužina podataka [7,8]; *P – prisustvo i tip bita parnosti [N(Bez parnosti),E(Parni paritet),O(Neparni paritet)]; *S – dužina stop bita [1, 1.5 ili 2]. primjer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Podešavanje protokola je opisano parametrom protokola. Sljedeće protokoli su podržani: *'modbus', Modbus protokol, na kraju preusmjeravanja se dodaje kontrolni zbroj CRC16(Modbus); *'dmx', DMX protokol; *'CO2' za povezivanje Larnitech CO2 senzora; *'salda' za spajanje Salda ventilacije. primjer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Za provjeru postavki i testiranje parametar eho se može koristiti. Modul echo-reply se može uključiti ili isključiti uz pomoć ovog parametra. Vrijednost parametra Echo: *'isključeno' *'na' primjer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h čeština (cs) | *'e' - inverzní tlačítko LED *'d' - LED tlačítko *'c' - tlačítko inverzní *'b' - tlačítko *'s' - přepínač *'k' - inverzní kontakt *'h' - kontakt *'l' - únik *'n' - Neptun *'v' - inverzní pohyb *'m' - pohyb *'r' - tepelný odpor *'t' - DALLAS *'-' - žádný Příklad: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", kde *pwm_invert – PWM invertování [1, 0]; *lbn_bright – jas tlačítek LED, rozsah (0 - 255); *f – výchozí frekvence PWM je 1000, rozsah (1 - 5000). Příklad: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Pouze pro Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', kde *SPEED – přenosová rychlost [1200..115200]; *B – délka dat [7,8]; *P – přítomnost a typ paritního bitu [N(žádná parita),E(sudá parita),O(lichá parita)]; *S – délka stop bitu [1, 1,5 nebo 2]. Příklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Nastavení protokolu je popsáno parametrem protokol. Následující jsou podporovány protokoly: *'modbus', protokol Modbus, na konci přesměrování je přidán kontrolní součet CRC16(Modbus); *'dmx', DMX protokol; *'CO2' pro připojení senzorů CO2 Larnitech; *'salda' pro připojení ventilace Salda. Příklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Pro kontrolu nastavení a testování lze použít parametr echo. Modul echo-reply lze zapnout nebo vypnout pomocí tohoto parametru. Hodnota parametru Echo: *'vypnuto' *'na' Příklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h dansk (da) | *'e' - led-knap omvendt *'d' - led-knap *'c' - knap omvendt *'b' - knap *'s' - skifte *'k' - kontakt omvendt *'h' - kontakt *'l' - lækage *'n' - Neptun *'v' - bevægelse invers *'m' - bevægelse *'r' - termo-modstand *'t' - DALLAS *'-' - ingen Eksempel: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", hvor *pwm_invert – PWM-invertering [1, 0]; *lbn_bright – lysstyrke af LED-knapper, rækkevidde (0 - 255); *f – som standard er PWM-frekvensen 1000, område (1 - 5000). Eksempel: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Kun til Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', hvor *SPEED – baudrate [1200..115200]; *B – datalængde [7,8]; *P – tilstedeværelse og type af paritetsbit [N(Ingen paritet),E(Lige paritet),O(Ulige paritet)]; *S – stopbitlængde [1, 1,5 eller 2]. Eksempel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Protokolindstilling er beskrevet af protokolparameter. Det følgende protokoller understøttes: *'modbus', Modbus-protokol, ved slutningen af omdirigeringen tilføjes kontrolsummen CRC16(Modbus); *'dmx', DMX-protokol; *'CO2' til tilslutning af Larnitech CO2-sensorer; *'salda' til tilslutning af Salda ventilation. Eksempel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Til indstillinger kan tjek ud og teste ekkoparameteren bruges. modul echo-reply kan slås til eller fra ved hjælp af denne parameter. Echo parameter værdi: *'af' *'på' Eksempel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h Deutsch (de) | *e' - led-taste invers *'d' - led-taste *'c' - Taste invers *'b' - Taster *'s' - Schalter *'k' - Kontakt invers *'h' - Kontakt *'l' - Leck *'n' - Neptun *'v' - Bewegung invers *'m' - Bewegung *'r' - Thermowiderstand *'t' - DALLAS *'-' - keine Beispiel: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", wobei *pwm_invert - PWM-Invertierung [1, 0]; *lbn_bright - Helligkeit der LED-Tasten, Bereich (0 - 255); *f - standardmäßig ist die PWM-Frequenz 1000, Bereich (1 - 5000). Beispiel: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Nur für Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', wobei *SPEED - Baudrate [1200..115200]; *B - Datenlänge [7,8]; *P - Vorhandensein und Art des Paritätsbits [N(Keine Parität),E(Gerade Parität),O(Ungerade Parität)]; *S - Länge des Stoppbits [1, 1,5 oder 2]. Beispiel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Die Protokolleinstellung wird durch Protokollparameter beschrieben. Die folgenden Protokolle werden unterstützt: *'modbus', Modbus-Protokoll, am Ende der Umleitung wird die Prüfsumme CRC16 (Modbus) hinzugefügt; *'dmx', DMX-Protokoll; *'CO2' für den Anschluss von Larnitech CO2-Sensoren; *'salda' für den Anschluss der Salda-Lüftung. Beispiel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Zum Einstellen und Testen können die Echo-Parameter verwendet werden. Modul echo-reply kann mit Hilfe dieses Parameters ein- oder ausgeschaltet werden.echo parameter value: *'off' *'ein' Beispiel: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h English (en) | *'e' - led-button inverse *'d' - led-button *'c' - button inverse *'b' - button *'s' - switch *'k' - contact inverse *'h' - contact *'l' - leak *'n' - Neptun *'v' - motion inverse *'m' - motion *'r' - thermo-resistor *'t' - DALLAS *'-' - none Example: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", where *pwm_invert – PWM inverting [1, 0]; *lbn_bright – brightness of led buttons, range (0 - 255); *f – by default PWM frequency is 1000, range (1 - 5000). Example: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Only for Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', where *SPEED – baud rate [1200..115200]; *B – data length [7,8]; *P – presence and type of parity bit [N(No parity),E(Even parity),O(Odd parity)]; *S – stop bit length [1, 1.5 or 2]. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Protocol setting is described by protocol parameter. The following protocols are supported: *'modbus', Modbus protocol, at the end of redirection the checksum CRC16(Modbus) is added; *'dmx', DMX protocol; *'CO2' for connecting Larnitech CO2 sensors; *'salda' for connecting Salda ventilation. Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||For settings check out and testing echo parameter can be used. Module echo-reply can be turned on or off with the help of this parameter.Echo parameter value: *'off' *'on' Example: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h español (es) | *'e' - botón led inverso *'d' - led-botón *'c' - botón inverso *'b' - botón *'s' - interruptor *k - contacto inverso *h - contacto *'l' - fuga *'n' - Neptun *v - movimiento inverso *'m' - movimiento *'r' - termorresistencia *'t' - DALLAS *'-' - ninguno Ejemplo: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", donde *pwm_invert - PWM inversor [1, 0]; *lbn_bright - brillo de los botones led, rango (0 - 255); *f - por defecto la frecuencia PWM es 1000, rango (1 - 5000). Ejemplo: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Sólo para Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', donde *SPEED - velocidad en baudios [1200..115200]; *B - longitud de los datos [7,8] *P - presencia y tipo de bit de paridad [N(Sin paridad),E(Paridad par),O(Paridad impar)]; *S - longitud del bit de parada [1, 1,5 ó 2]. Ejemplo: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||La configuración del protocolo se describe mediante el parámetro de protocolo. Se admiten los siguientes siguientes protocolos: *'modbus', protocolo Modbus, al final de la redirección se añade la suma de comprobación CRC16(Modbus); *'dmx', protocolo DMX; *'CO2' para conectar sensores de CO2 Larnitech; *'salda' para conectar la ventilación Salda. Ejemplo: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Para la comprobación de los ajustes y las pruebas se puede utilizar el parámetro eco. Módulo echo-reply se puede activar o desactivar con la ayuda de este parámetro.valor del parámetro Echo: *'off' *activado Ejemplo: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h français (fr) | *'e' - bouton led inverse *'d' - bouton à led *'c' - bouton inverse *'b' - bouton *'s' - interrupteur *k" - contact inversé *'h' - contact *'l' - fuite *'n' - Neptun *'v' - mouvement inverse *'m' - mouvement * "r" - thermorésistance * "t" - DALLAS *'-' - aucun Exemple : io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", où *pwm_invert - Inversion PWM [1, 0] ; *lbn_bright - luminosité des boutons à DEL, plage (0 - 255) ; *f - la fréquence PWM par défaut est de 1000, plage (1 - 5000). Exemple : <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Uniquement pour Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', où *SPEED - débit en bauds [1200..115200] ; *B - longueur des données [7,8] ; *P - présence et type de bit de parité [N(No parity),E(Even parity),O(Odd parity)] ; *S - longueur du bit d'arrêt [1, 1,5 ou 2]. Exemple : <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Le réglage du protocole est décrit par le paramètre de protocole. Les protocoles suivants Les protocoles suivants sont pris en charge : *'modbus', protocole Modbus, à la fin de la redirection, la somme de contrôle CRC16 (Modbus) est ajoutée ; *'dmx', protocole DMX ; *'CO2' pour connecter les capteurs de CO2 de Larnitech ; *'salda' pour connecter la ventilation Salda. Exemple : <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Le paramètre écho peut être utilisé pour vérifier les réglages et les tests. Module L'écho peut être activé ou désactivé à l'aide de ce paramètre : *'off' *'on' Valeur du paramètre d'écho : *'off' *'on' Exemple : <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h Ἀρχαία ἑλληνικὴ (grc) | *'e' - αντίστροφο κουμπί led *'d' - κουμπί led *'c' - κουμπί αντίστροφο *'b' - κουμπί *'s' - διακόπτης *'k' - αντίστροφη επαφή *'h' - επαφή *'l' - διαρροή *'n' - Neptun *'v' - αντίστροφη κίνηση *'m' - κίνηση *'r' - θερμοαντίσταση *'t' - ΝΤΑΛΑΣ *'-' - κανένα Παράδειγμα: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", που *pwm_invert – PWM inverting [1, 0]; *lbn_bright – φωτεινότητα κουμπιών led, εύρος (0 - 255); *f – από προεπιλογή η συχνότητα PWM είναι 1000, εύρος (1 - 5000). Παράδειγμα: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Μόνο για το Metaforsa 3.plus'''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', που *ΤΑΧΥΤΗΤΑ – ρυθμός baud [1200..115200]; *B – μήκος δεδομένων [7,8]; *P – παρουσία και τύπος bit ισοτιμίας [N(Χωρίς ισοτιμία),E(Ζυγή ισοτιμία),O(Μονή ισοτιμία)]; *S – μήκος bit διακοπής [1, 1,5 ή 2]. Παράδειγμα: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Η ρύθμιση πρωτοκόλλου περιγράφεται από την παράμετρο πρωτοκόλλου. Το ακόλουθο υποστηρίζονται τα πρωτόκολλα: *'modbus', πρωτόκολλο Modbus, στο τέλος της ανακατεύθυνσης προστίθεται το άθροισμα ελέγχου CRC16(Modbus). *'dmx', πρωτόκολλο DMX. *'CO2' για σύνδεση αισθητήρων CO2 της Larnitech. *'salda' για σύνδεση εξαερισμού Salda. Παράδειγμα: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Για τις ρυθμίσεις ελέγξτε έξω και η παράμετρος ηχούς δοκιμής μπορεί να χρησιμοποιηθεί. Μονάδα μέτρησης Η echo-reply μπορεί να ενεργοποιηθεί ή να απενεργοποιηθεί με τη βοήθεια αυτής της παραμέτρου.Τιμή παραμέτρου Echo: *'μακριά από' *'επί' Παράδειγμα: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h magyar (hu) | *'e' - led-gomb inverz *'d' - led-gomb *'c' - gomb inverz *'b' - gomb *'s' - kapcsoló *'k' - érintkezés inverze *'h' - kapcsolat *'l' - szivárog *'n' - Neptun *'v' - inverz mozgás *'m' - mozgás *'r' - hőellenállás *'t' - DALLAS *'-' - egyik sem Példa: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", ahol *pwm_invert – PWM invertálás [1, 0]; *lbn_bright – LED gombok fényereje, tartomány (0 - 255); *f – alapértelmezés szerint a PWM frekvencia 1000, tartomány (1-5000). Példa: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Csak a Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', ahol *SPEED – adatátviteli sebesség [1200..115200]; *B – adathossz [7,8]; *P – a paritásbit jelenléte és típusa [N(Nincs paritás),E(Páros paritás),O(Páratlan paritás)]; *S – stopbit hossza [1, 1,5 vagy 2]. Példa: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||A protokoll beállítását a protokoll paraméter írja le. A következő protokollok támogatottak: *'modbus', Modbus protokoll, az átirányítás végén hozzáadódik a CRC16(Modbus) ellenőrző összeg; *'dmx', DMX protokoll; *'CO2' a Larnitech CO2-érzékelők csatlakoztatásához; *'salda' a Salda szellőztetés csatlakoztatásához. Példa: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||A beállításokhoz ellenőrizze és tesztelje az echo paramétert. Modul Az echo-reply ennek a paraméternek a segítségével kapcsolható be vagy ki.Echo paraméter értéke: *'ki' *'tovább' Példa: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h italiano (it) | *'e' - pulsante led inverso *'d' - pulsante a led *'c' - pulsante inverso *'b' - pulsante *'s' - interruttore *'k' - contatto inverso *'h' - contatto *'l' - perdita *'n' - Nettuno *'v' - movimento inverso *'m' - movimento *'r' - termoresistenza *'t' - DALLAS *'-' - nessuno Esempio: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", dove *pwm_invert - inversione PWM [1, 0]; *lbn_bright - luminosità dei pulsanti a led, intervallo (0 - 255); *f - la frequenza PWM predefinita è 1000, intervallo (1 - 5000). Esempio: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Solo per Metaforsa 3.plus'' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', Solo per Metaforsa 3.plus'' dove *SPEED - velocità di trasmissione [1200..115200]; *B - lunghezza dati [7,8]; *P - presenza e tipo di bit di parità [N(No parity),E(Even parity),O(Odd parity)]; *S - lunghezza del bit di stop [1, 1,5 o 2]. Esempio: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||L'impostazione del protocollo è descritta dal parametro di protocollo. Sono supportati i seguenti sono supportati i seguenti protocolli: *'modbus', protocollo Modbus; alla fine del reindirizzamento viene aggiunto il checksum CRC16 (Modbus); *'dmx', protocollo DMX; *'CO2' per il collegamento dei sensori di CO2 Larnitech; *'salda' per il collegamento della ventilazione Salda. Esempio: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Per la verifica delle impostazioni e il test si può utilizzare il parametro eco. Modulo echo-reply può essere attivato o disattivato con l'aiuto di questo parametro.Valore del parametro echo: *'off' *'on' Esempio: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h lietuvių (lt) | *'e' - LED mygtukas atvirkštinis *'d' - LED mygtukas *'c' - mygtukas atvirkštinis *'b' - mygtukas *'s' - jungiklis *'k' – atvirkštinis kontaktas *'h' - susisiekite *'l' - nutekėjimas *'n' - Neptūnas *'v' – atvirkštinis judėjimas *'m' - judesys *'r' - termorezistorius *'t' - DALAS *'-' - nė vienas Pavyzdys: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", kur *pwm_invert – PWM invertavimas [1, 0]; *lbn_bright – LED mygtukų ryškumas, diapazonas (0 - 255); *f – pagal numatytuosius nustatymus PWM dažnis yra 1000, diapazonas (1–5000). Pavyzdys: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Tik Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', kur *SPEED – perdavimo sparta [1200..115200]; *B – duomenų ilgis [7,8]; *P – pariteto bito buvimas ir tipas [N(No parity),E(Even parity),O(Odd parity)]; *S – stop bito ilgis [1, 1,5 arba 2]. Pavyzdys: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Protokolo nustatymas aprašomas protokolo parametru. Sekantis palaikomi protokolai: *'modbus', Modbus protokolas, peradresavimo pabaigoje pridedama kontrolinė suma CRC16(Modbus); *'dmx', DMX protokolas; *'CO2' skirtas Larnitech CO2 jutikliams prijungti; *'salda' skirta Salda ventiliacijai prijungti. Pavyzdys: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Nustatymams patikrinti ir testuoti galima naudoti aido parametrą. Modulis echo-reply galima įjungti arba išjungti naudojant šį parametrą.Aido parametro reikšmė: *'išjungta' *"įjungta" Pavyzdys: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h Nederlands (nl) | *'e' - led-knop invers *'d' - led-knop *'c' - knop invers *'b' - knop *'s' - schakelaar *'k' - contact invers *'h' - contact *'l' - lek *'n' - Neptunus *'v' - beweging invers *'m' - beweging *'r' - thermo-weerstand *'t' - DALLAS *'-' - geen Voorbeeld: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", waarbij *pwm_invert - PWM inverteren [1, 0]; *lbn_bright - helderheid van ledknoppen, bereik (0 - 255); *f - standaard PWM-frequentie is 1000, bereik (1 - 5000). Voorbeeld: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Alleen voor Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', waarbij *SPEED - baudrate [1200..115200]; *B - gegevenslengte [7,8]; *P - aanwezigheid en type van pariteitsbit [N(Geen pariteit),E(Even pariteit),O(Oneven pariteit)]; *S - stopbitlengte [1, 1,5 of 2]. Voorbeeld: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||De protocolinstelling wordt beschreven door de protocolparameter. De volgende protocollen worden ondersteund: *'modbus', Modbus-protocol; aan het einde van de omleiding wordt de controlesom CRC16(Modbus) toegevoegd; *'dmx', DMX-protocol; *'CO2' voor het aansluiten van Larnitech CO2-sensoren; *'salda' voor het aansluiten van Salda ventilatie. Voorbeeld: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Voor het controleren en testen van instellingen kan de echoparameter worden gebruikt. Module echo-reply kan worden in- of uitgeschakeld met behulp van deze parameter.Echo parameter waarde: *'off' *'aan Voorbeeld: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h polski (pl) | *'e' - odwrotność przycisku LED *'d' - przycisk LED *'c' - przycisk odwrócony *'b' - przycisk *'s' - przełącznik *'k' - styk odwrócony *'h' - kontakt *'l' - wyciek *'n' - Neptun *'v' - ruch odwrotny *'m' - ruch *'r' - termorezystor *'nie' - DALLAS *'-' - nic Przykład: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", Gdzie *pwm_invert – odwracanie PWM [1, 0]; *lbn_bright – jasność przycisków LED, zakres (0 - 255); *f – domyślnie częstotliwość PWM wynosi 1000, zakres (1 - 5000). Przykład: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Tylko dla Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', Gdzie *SPEED – prędkość transmisji [1200..115200]; *B – długość danych [7,8]; *P – obecność i rodzaj bitu parzystości [N(Brak parzystości),E(Parzystość),O(Nieparzystość)]; *S – długość bitu stopu [1, 1,5 lub 2]. Przykład: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Ustawienie protokołu jest opisane parametrem protokołu. Następujące obsługiwane protokoły: *'modbus', protokół Modbus, na końcu przekierowania dodawana jest suma kontrolna CRC16(Modbus); *'dmx', protokół DMX; *'CO2' do podłączenia czujników CO2 firmy Larnitech; *'salda' do podłączenia wentylacji Salda. Przykład: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Do sprawdzania ustawień i testowania można użyć parametru echo. Moduł Za pomocą tego parametru można włączyć lub wyłączyć echo-reply. Wartość parametru Echo: *'wyłączony' *'NA' Przykład: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h português (pt) | *'e' - botão led inverso *'d' - botão led *'c' - botão inverso *'b' - botão *'s' - mudar *'k' - contato inverso *'h' - contato *'l' - vazamento *'n' - Netuno *'v' - movimento inverso *'m' - movimento *'r' - termo-resistor *'t' - DALLAS *'-' - nenhum Exemplo: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", onde *pwm_invert – Inversão PWM [1, 0]; *lbn_bright – brilho dos botões led, faixa (0 - 255); *f – por padrão, a frequência PWM é 1000, faixa (1 - 5000). Exemplo: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Apenas para Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', onde *SPEED – taxa de transmissão [1200..115200]; *B – comprimento dos dados [7,8]; *P – presença e tipo de bit de paridade [N(Sem paridade),E(Paridade par),O(Paridade ímpar)]; *S – comprimento do bit de parada [1, 1,5 ou 2]. Exemplo: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||A configuração do protocolo é descrita pelo parâmetro do protocolo. A seguir protocolos são suportados: *'modbus', protocolo Modbus, ao final do redirecionamento é adicionado o checksum CRC16(Modbus); *'dmx', protocolo DMX; *'CO2' para conexão de sensores de CO2 da Larnitech; *'salda' para conectar a ventilação Salda. Exemplo: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Para configurações, check-out e teste, o parâmetro echo pode ser usado. Módulo A resposta de eco pode ser ativada ou desativada com a ajuda deste parâmetro. Valor do parâmetro Echo: *'desligado' *'sobre' Exemplo: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h română (ro) | *'e' - buton-led invers *'d' - buton-led *'c' - buton invers *'b' - buton *'s' - comutator *'k' - contact invers *'h' - contact *'l' - scurgere *'n' - Neptun *'v' - mișcare inversă *'m' - mișcare *'r' - termorezistor *'t' - DALLAS *'-' - nici unul Exemplu: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", Unde *pwm_invert – inversare PWM [1, 0]; *lbn_bright – luminozitatea butoanelor led, interval (0 - 255); *f – în mod implicit frecvența PWM este 1000, interval (1 - 5000). Exemplu: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Numai pentru Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', Unde *SPEED – baud rate [1200..115200]; *B – lungimea datelor [7,8]; *P – prezența și tipul bitului de paritate [N(Fără paritate),E(paritate pară),O(paritate impară)]; *S – lungimea bitului de oprire [1, 1,5 sau 2]. Exemplu: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Setarea protocolului este descrisă de parametrul protocolului. Următoarele protocoalele sunt acceptate: *'modbus', protocol Modbus, la sfârșitul redirecționării se adaugă suma de control CRC16(Modbus); *'dmx', protocol DMX; *'CO2' pentru conectarea senzorilor de CO2 Larnitech; *'salda' pentru conectarea ventilației Salda. Exemplu: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Pentru setări verificați și testați parametrul ecou poate fi utilizat. Modul echo-reply poate fi activat sau dezactivat cu ajutorul acestui parametru. Valoarea parametrului Echo: *'off' *'pe' Exemplu: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h русский (ru) | *'e' - светодиодная кнопка инверсия *'d' - светодиодная кнопка *'c' - кнопка реверса *'b' - кнопка *'s' - переключатель *'k' - контакт инверсный *'h' - контакт *'l' - утечка *'n' - Нептун. *'v' - реверс движения. *M - движение* *R - терморезистор* *Т - Даллас* *'-' - нет Пример: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", где *pwm_invert - инвертирование ШИМ [1, 0]; *lbn_bright - яркость подсветки кнопок, диапазон (0 - 255); *f - по умолчанию частота ШИМ 1000, диапазон (1 - 5000). Пример: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Только для Metaforsa 3.plus'' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', где *SPEED - скорость передачи данных [1200..115200]; *B - длина данных [7,8]; *P - наличие и тип бита четности [N(No parity), E(Even parity), O(Odd parity)]; *S - длина стоп-бита [1, 1.5 или 2]. Пример: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Настройка протокола описывается параметром протокола. Поддерживаются следующие протоколы поддерживаются: *'modbus', протокол Modbus, в конце перенаправления добавляется контрольная сумма CRC16(Modbus); *'dmx', протокол DMX; *'CO2' для подключения датчиков CO2 Larnitech; *'salda' для подключения вентиляции Salda. Пример: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Для проверки и тестирования настроек можно использовать параметр эхосигнала. Модуль С помощью этого параметра можно включить или выключить эхо-ответ.Значение параметра Echo: *'off' *'on' Пример: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h slovenčina (sk) | *'e' - inverzné tlačidlo LED *'d' - tlačidlo LED *'c' - tlačidlo inverzné *'b' - tlačidlo *'s' - prepínač *'k' - inverzný kontakt *'h' - kontakt *'l' - únik *'n' - Neptún *'v' - inverzný pohyb *'m' - pohyb *'r' - tepelný odpor *'t' - DALLAS *'-' - žiadne Príklad: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", kde *pwm_invert – PWM invertovanie [1, 0]; *lbn_bright – jas tlačidiel LED, rozsah (0 - 255); *f – predvolená frekvencia PWM je 1000, rozsah (1 - 5000). Príklad: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Len pre Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', kde *SPEED – prenosová rýchlosť [1200..115200]; *B – dĺžka údajov [7,8]; *P – prítomnosť a typ paritného bitu [N(žiadna parita),E(párna parita),O(nepárna parita)]; *S – dĺžka stop bitu [1, 1,5 alebo 2]. Príklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Nastavenie protokolu popisuje parameter protokolu. Nasledujúci podporované protokoly: *'modbus', protokol Modbus, na konci presmerovania sa pridá kontrolný súčet CRC16(Modbus); *'dmx', DMX protokol; *'CO2' na pripojenie snímačov CO2 Larnitech; *'salda' na pripojenie ventilácie Salda. Príklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Na kontrolu nastavení a testovanie parametra echo je možné použiť. modul echo-reply možno zapnúť alebo vypnúť pomocou tohto parametra. Hodnota parametra Echo: *'vypnuté' *'zap' Príklad: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h slovenščina (sl) | *'e' - inverzna led tipka *'d' - LED-gumb *'c' - inverzni gumb *'b' - gumb *'s' - stikalo *'k' - stik inverzno *'h' - stik *'l' - puščanje *'n' - Neptun *'v' - obratno gibanje *'m' - gibanje *'r' - termo-upor *'t' - DALLAS *'-' - nič primer: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", kje *pwm_invert – obračanje PWM [1, 0]; *lbn_bright – svetlost LED gumbov, obseg (0 - 255); *f – privzeta frekvenca PWM je 1000, razpon (1 - 5000). primer: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Samo za Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', kje *SPEED – hitrost prenosa [1200..115200]; *B – dolžina podatkov [7,8]; *P – prisotnost in vrsta paritetnega bita [N(Brez parnosti),E(Soda parnost),O(Liha parnost)]; *S – dolžina stop bita [1, 1,5 ali 2]. primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Nastavitev protokola je opisana s parametrom protokola. Naslednji podprti so protokoli: *'modbus', protokol Modbus, na koncu preusmeritve se doda kontrolna vsota CRC16(Modbus); *'dmx', protokol DMX; *'CO2' za priključitev senzorjev Larnitech CO2; *'salda' za priklop prezračevanja Salda. primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Za preverjanje nastavitev in testiranje odmevnega parametra je mogoče uporabiti. Modul echo-reply lahko vklopite ali izklopite s pomočjo tega parametra. Vrednost parametra Echo: *'izklopljeno' *'on' primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h српски / srpski (sr) | *'e' - LED dugme inverzno *'d' - LED dugme *'c' - dugme obrnuto *'b' - dugme *'s' - prekidač *'k' - kontakt inverzan *'h' - kontakt *'l' - curenje *'n' - Neptun *'v' - inverzno kretanje *'m' - pokret *'r' - termo-otpornik *'t' - DALLAS *'-' - nijedan Primer: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", gde *pvm_invert – PVM invertovanje [1, 0]; *lbn_bright – osvetljenost LED tastera, opseg (0 - 255); *f – podrazumevano je PVM frekvencija 1000, opseg (1 - 5000). Primer: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Samo za Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', gde *SPEED – brzina prenosa [1200..115200]; *B – dužina podataka [7,8]; *P – prisustvo i tip bita parnosti [N(bez parnosti),E(parni paritet),O(neparni paritet)]; *S – dužina stop bita [1, 1,5 ili 2]. Primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Podešavanje protokola je opisano parametrom protokola. Sledeće protokoli su podržani: *'modbus', Modbus protokol, na kraju preusmeravanja se dodaje kontrolni zbir CRC16(Modbus); *'dmk', DMKS protokol; *'CO2' za povezivanje Larnitech CO2 senzora; *'salda' za povezivanje Salda ventilacije. Primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Za proveru podešavanja i testiranje eho parametar se može koristiti. Modul echo-repli se može uključiti ili isključiti uz pomoć ovog parametra. Vrednost parametra Echo: *'van' *'na' Primer: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |
h українська (uk) | *'e' - світлодіодна кнопка інверсія *'d' - світлодіодна кнопка *'c' - кнопка реверсу *'b' - кнопка *'s' - перемикач *'k' - контакт інверсний *"h" - контакт *'l' - витік *"n" - Нептун. *"v" - реверс руху. *"m" - рух *"r" - терморезистор *"т" - Даллас. *'-' - немає Приклад: io='KKKKKKKKKKKKKKKKKKKKKKKKKKKK' |- |hw||string||98||-||hw="...", де *pwm_invert - інвертування ШІМ [1, 0]; *lbn_bright - яскравість підсвічування кнопок, діапазон (0 - 255); *f - за замовчуванням частота ШІМ 1000, діапазон (1 - 5000). Приклад: <syntaxhighlight lang="xml" line> hw="io='4---zdd----t--' pwm_invert=1 lbn_bright=255 f=1000" </syntaxhighlight> |- |colspan="3"|'''Тільки для Metaforsa 3.plus''' |- |cfg||string||98||9600/8N1||cfg='SPEED/BPS', де *SPEED - швидкість передачі даних [1200..115200]; *B - довжина даних [7,8]; *P - наявність та тип біту парності [N(No parity), E(Even parity), O(Odd parity)]; *S - довжина стоп-біта [1, 1.5 або 2]. Приклад: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1'" </syntaxhighlight> |- |[Protocol]||string||98||—||Налаштування протоколу описується параметром протоколу. Підтримуються наступні протоколи підтримуються: *'modbus', протокол Modbus, в кінці перенаправлення додається контрольна сума CRC16(Modbus); *'dmx', протокол DMX; *'CO2' для підключення датчиків CO2 Larnitech; *'salda' для підключення вентиляції Salda. Приклад: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' modbus" </syntaxhighlight> |- |echo||on; off||98||'off'||Для перевірки та тестування налаштувань можна використовувати параметр ехосигналу. Модуль за допомогою цього параметра можна ввімкнути або вимкнути ехо-відповідь.Значення параметра Echo: *'off' *'on' Приклад: <syntaxhighlight lang="xml" line> hw="cfg='9600/8N1' echo='off'" </syntaxhighlight> |} |