 h English (en)'''Overview of the METAFORSA device external connectors:''' In the upper part of the casing (fig. 1) there are 5 connectors with screw clamps. Connectors: (1) – contact points (L1, L2), (3) – contact points (L3, L4) and (5) – contact point (L5) – phase conductor connection for load switching of the channels C1-C4, C5-C8, and C9-C10 respectively. The parallel connection of two contact points is used in connectors (1) and (3) in order to increase the capacity. Connectors: (2) – C1-C4 contact points, (4) – contact points C5-C8 and (5) – C9-C10 – are used for load connection (of actuators – lights, valves, curtain drives, etc.). Internal circuit for output switching is shown in '''fig. 2.'''
 h русский (ru)'''Схема внешних разъемов устройства МЕТАФОРСА:''' В верхней части корпуса (рис. 1) расположены 5 разъемов с винтовыми зажимами. Разъемы: (1) - контакты (L1, L2), (3) - контакты (L3, L4) и (5) - контакт (L5) для подключения фазного провода для переключения нагрузки каналов C1-C4, C5 -C8 и C9-C10 соответственно. В разъемах (1) и (3) используется параллельное соединение двух контактов для увеличения емкости. Разъемы: (2) - контакты C1-C4, (4) - контакты C5-C8 и (5) - C9-C10 - используются для подключения нагрузки (приводов - освещения, клапанов, приводов штор и т. д.). Внутренняя схема переключения выходов показана на '''рис. 2'''