h English (en) | {|class="wikitable" |- !Name!!type and variety!!description!!default value |- |co2-sensors||list||list of valve co2 sensors (for automation)||- |- |automation||string||name of current automation mode||- |- |undefined-behavior||0-250/on/off/last||ventilation position in case of sensors readings absence (off – 0; on – 250)||last |- |P0||0-100||minimal power for turning on fan||last |- |alg||string||eco/fast/boost alg||- |- |limit-fan||number(0-250)|| max power |- |ctrl-change1||number(0-250)|| min level of power change (one time per "ctrl-ticks" attr) if defined||5 |- |ctrl-change2||number(0-250)||min level of power change||- |- |ctrl-ticks||number(0-3825)||power change by "ctrl-change1" timeout||- |} |
h русский (ru) | {|class="wikitable" |- !Название!!Тип и диапазон!!Описание!!Значение по умолчанию |- |co2-sensors||список||Список датчиков co2 клапана (для автоматизации)||- |- |automation||строка||Название текущего режима автоматизации||- |- |undefined-behavior||0-250/вкл./выкл./последнее||Положение вентиляции при отсутствии показаний датчиков (выкл. – 0; вкл. – 250)||последнее |- |P0||0-100||Минимальная мощность для включения вентилятора||последнее |- |alg||строка||Алгоритм режима работы эко/быстрый/ускоренный||- |- |limit-fan||число (0-250)||Максимальная мощность |- |ctrl-change1||число (0-250)||Минимальный уровень изменения мощности (один шаг на атрибут "ctrl-ticks"), если он определен||5 |- |ctrl-change2||число (0-250)||Минимальный уровень изменения мощности||- |- |ctrl-ticks||число (0-3825)||изменение мощности по таймауту "ctrl-change1"||- |} |