Other
Supply voltage23…26V DC
Dimentions140x64x30 mm


MEDIA POINT

Multiroom system media point with a built-in amplifier. Used to play music, the Internet radio, system notifications. Supports DLNA protocol. Can be used either within the Smart Home system or separately.

Example of connection

MPC EXA.png

Module parameters

Parameter name Value
Analog output channels qty 2
Speakers 4-8 ohm
Max power output audio channel 2x20W
Connection type Ethernet
Transfer data speed 10/100 MB/s
Power supply 23…26V DC
Max current(24V) 3.3 A,
24V 4.2 A Recomended
Case material Aluminium
Protection IP40
Mounting type Free
Temperature range -10…+50 °C
Dimensions 140x64x30 mm
Weigth 500 g

Indication of module operation

Indicator Status Description
Power Gl.png Power
E.png Power not available
Activity Y.png Data communication
E.png Data communication not available
Error E.png No errors
Rl.png Overheating
R.pngR.png No connection to AC.
R.pngR.pngR.pngDots.png The data has not been transferred via the CAN bus for at least 5 minutes.
R.pngR.pngR.pngDots.png No power on the lamp.
R.pngR.pngR.pngDots.png No power on the DALI bus or over current (more then 180 mA) on DALI bus. If over current is at both bus blinking twice in half a second.

HW settings

Name Type, range SUBID Default Description
slaves ID:SID,ID:SID 30 Syncs master and slaves media points. Example:
1hw="slaves='ID:SID,ID:SID'"
ss int (0…10000) 30 Smooth increase speaker volume (0..10000 milliseconds) Example:
1hw="ss=2000"
play-lim int (-100…1440) 30 0 Stop playback after a certain number of tracks / seconds(<0 - tracks; >0 – seconds) Example:
1hw="play-lim=-12"
1<item addr="582:30" cfgid="68" name="speaker" type="speaker" hw="slaves='321:30,452:30' ss=5500" uniq_id="4620"/>
2<item addr="582:98" cfgid="68" name="CPU" system="yes" type="temperature-sensor" uniq_id="4621"/>