Open main menu
Home
How to do
Din rail devices
Box devices
Sensors
Multiroom
Applicatin
XML
Additional info
Log in
Settings
Larnitech wiki page
Search
Translations:Metaforsa 3/3.plus/1/lt
Language
Watch
Edit
Revision as of 08:42, 8 April 2024 by
Support
(
talk
|
contribs
)
(Created page with "{{Infobox module | name = MF3/MF3.plus | image = METAFORSA_3_MF3-14.png | maxcandev = 4 (can be extended with the license) 99 (for Metaforsa 3.plus) | canbuslen...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
MF3/MF3.plus
Output ports
Number of switched channels
10
Number of dimming channels
4
Peak load
16 A
Max load per dimming channel
0.5 A (110 W at 220 V)
Dimmer type
MOSFET
Input ports
Number of discrete inputs
28
General
Max CAN devices
4 (can be extended with the license) 99 (for Metaforsa 3.plus)
Max CAN bus length
800 m (twisted pair CAT5e)
Max current per CAN bus
500 mA
Other
Supply voltage
11.5...27.5 V DC
Dimentions
9U, 156x90x58 mm