Revision:
/B
/C


DE-MG.plus
DE-MGPC.png
General
Type of connectionCAN, Ethernet
Input/output interfacesEthernet, 2xCAN, EIB, Bluetooth
Max CAN devices100(50 per CAN)
CAN port qty2
Max CAN bus length800 m (twisted pair 5 cat)
Max current per CAN bus700mA
Other
Supply voltage11.5...27.5 V DC
Dimentions2U, 36x102x58 mm


MAIN GATEWAY

It is used for accumulation and storage of system data. The device determines the logical scheme of the system and allows authorized access to the system via the Internet. It also converts Ethernet into CAN bus and vice versa. DE-MG has a built-in IR receiver.The DE-MG can be controlled via cloud with a securely encrypted signal. The system history from all other devices and sensors is stored on the DE-MG for one year. Its plug and play feature means that it automatically detects and configures new Larnitech devices that are added to the system. A large and constantly updated database of ready-made scripts ensures that your home does everything your heart may desire. Get things going by telling your home what to do with the help of Siri, Alexa or Google Home. Get push notifications on your phone whenever the system has things to tell you and enjoy the ultimate control at your fingertips

Module view

 

  1. Indicators
  2. IR Reсiever
  3. Recovery button
  4. Power supply
  5. CAN1
  6. CAN2
  7. Ethernet
  8. EiB

Сonnection example

 

Module parameters

Parameter name Value
Type of connection CAN, Ethernet
Input/output interfaces Ethernet, 2xCAN, EIB, Bluetooth
Data speed 10/100Mb/s
Max CAN deviсes 100(50 per CAN)
CAN bus topology BUS
Number of CAN ports 2
Power supply 11.5 … 27.5 V DC
24V, 2.5A Recommended
Max own current (24V) 140mA
Max CAN bus length 800 m* (twisted pair 5 cat)
Max current per CAN bus 700mA
IR Receiver angle 30°
Case material ABS
Protection IP40
Equipment installation type DIN-rail (EN 60715)
Temperature range -10 … +50°C
Size 2U, 36x102x58 mm
Weight 145 g

* – installing additional power supply units is required for long lines; the maximum length of the line may be reduced by various interference factors

Indication of module operation

Indicator Status Description
Power   Power
  Power not available
Activity   Data communication
  Data communication not available
Error   No errors
  Overheating
   No connection to AC.
     The data has not been transferred via the CAN bus for at least 5 minutes.
     No power on the lamp.
     No power on the DALI bus or over current (more then 180 mA) on DALI bus. If over current is at both bus blinking twice in half a second.