EIB

Revision as of 13:16, 16 November 2021 by Erich (talk | contribs) (→‎LOG:)

Switch-press-release (Recommended)

Button configuration in ETS:


 

 

Configuration in EIB plugin:


 

LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/0 data len 1: 01  - Button pressed
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/0 data len 1: 00  - Button released
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/2 data len 1: 01  - Feedback sent

Comment:

For correct operation, it is required that the button, when pressed, should send 1, and when released, 0 This kind of configuration can be used for double, triple clicks and dimming

Switch-one-phys-btn

Button configuration in ETS:


 
Or:
 

 

Configuration in EIB plugin:


 

LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/3 destination 5/0/0 data len 1: 01 - Button pressed
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 5/0/1 data len 1: 01 - Feedback sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/3 destination 5/0/0 data len 1: 00 - Button pressed
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 5/0/1 data len 1: 00  - Feedback sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/3 destination 5/0/2 data len 1: 09 - Dimming UP started
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/3 destination 5/0/2 data len 1: 08 - Dimming UP finished
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/3 destination 5/0/2 data len 1: 01 - Dimming DOWN started
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/3 destination 5/0/2 data len 1: 00 - Dimming DOWN finished

Comment:

Each press of the button sends 1 byte of data (alternately 0 or 1). To start / stop dimming, the button sends 9/8 or 1/0 to the dimming group address.

Switch-two-phys-btn

Button configuration in ETS:


 

 

Configuration in EIB plugin:


 

LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/2 data len 1: 01 - Button 1 pressed
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/3 data len 1: 01  - Feedback 2 sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/0 data len 1: 01  - Feedback sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/2 data len 1: 00 - Button 2 pressed
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/3 data len 1: 00  - Feedback 2 sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/0 data len 1: 00  - Feedback sent

Comment:

This type of configuration is used if you have physically 2 buttons on a panel, one of which always sends the command on (1) and the second off (0). In this case, 2 buttons are created in the Larnitech system, each of which can be used independently. Most of the panels do not allow independent use of the feedback LEDs, therefore, if the keys are used independently, the indication may not work correctly.


Switch-long-press

Button configuration in ETS:


 

 

 

Configuration in EIB plugin:


 

LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/2 data len 1: 01  - Button 1 pressed
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/3 data len 1: 01 - Feedback 2 sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/0 data len 1: 01 - Feedback sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/2 data len 1: 00  - Button 2 pressed
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/3 data len 1: 00 - Feedback 2 sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 2/0/0 data len 1: 00 - Feedback sent
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/1 data len 1: 01 - Button 1 dimming started
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/1 data len 1: 00 - Button 1 dimming finished
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/1 data len 1: 09 - Button 2 dimming started
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 2/0/1 data len 1: 08 - Button 2 dimming finished

Comment:

Works the same as Switch-two-phys-btn, the difference is that dimming is added.


Temperature Sensor

Sensor configuration in ETS:


 

 

Configuration in EIB plugin:


 

LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/1/5 data len 3: 00 0c c4  - Received temperature from the sensor

Comment:

Creates a temperature sensor in the Larnitech system.

Thermostat

Thermostat configuration in ETS:


 

 

 

Configuration in EIB plugin:


 

LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 4/0/2 data len 3: 00 0c 4c - Setpoint sent to the thermostat
From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/0/1 data len 3: 00 0c 4c - Setpoint received from the thermostat

Comment:

The plugin ensures temperature setpoint synchronization between a thermostat and valve-heating element in the Larnitech system

Climate Control

Thermostat configuration in ETS:


 

 

 

 

 

 

Configuration in EIB plugin:


 

 

 


LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/3/1 data len 1: 00 - Turn OFF From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/0/1 data len 3: 00 0d 46 - Setpoint received

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/3/1 data len 1: 01 - Turn ON From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/0/1 data len 3: 00 0d 46 - Setpoint received


From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 4/0/2 data len 3: 00 0c e2 - Setpoint sent to the thermostat From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/0/1 data len 3: 00 0c e2 - Setpoint received

Comment:

Heat/Cool Setpoint - Must be selected if the thermostat panel has only 1 address for two setpoints. In this case, depending on the selected mode in the climate control, the following values will be taken:

  • If climate control is in heating mode, Heat/Cool setpoint will be accepted as the heating setpoint. Likewise within the Cooling mode, Heat/Cool setpoint will be accepted as the cooling setpoint.
  • If the climate control is in the Heating/Cooling mode, it will use add/subtract delta and set 2 setpoints (Heat and cool). For example setpoint 25 will be transformed to 23-27.


Air Conditioner

Configuration in ETS:


 

 

 

 

 

 

 

 


Configuration in EIB plugin:


 

 

LOG:

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/3/1 data len 1: 00 - Turn OFF From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/0/1 data len 3: 00 0d 46 - Setpoint received

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/3/1 data len 1: 01 - Turn ON From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/0/1 data len 3: 00 0d 46 - Setpoint received

From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/2/0 data len 2: 00 04 - Mode changed to Heating From EIB (BAOS, chID 0, seq_cntr 0) => source 15/15/255 destination 4/0/2 data len 3: 00 0c e2 - Setpoint sent From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/0/1 data len 3: 00 0c e2 - Setpoint received From EIB (BAOS, chID 0, seq_cntr 0) => source 1/1/1 destination 4/4/0 data len 2: 00 03 - Sending FAN speed

Comment:

In case the device does can't send mode with the DPT 20.105 data type, but simply sends [1,2,3,4,0…], you can set your own correspondence of values to the mode